Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Endocrinol Nutr ; 61(6): 318-22, 2014.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-24533929

RESUMO

BACKGROUND AND OBJECTIVE: Patients with type 1 diabetes (T1DM) treated with continuous subcutaneous insulin infusion (CSII) have available several specific features of these devices. The aim of this study was to evaluate the relationship between real use of them and the degree of glycemic control in patients using this therapy. PATIENTS AND METHODS: Forty-four T1DM patients on CSII therapy with or without real-time continuous glucose monitoring (CGM) were included. Data from 14 consecutive days were retrospectively collected using the therapy management software CareLink Personal/Pro(®) and HbA1c measurement performed at that period. The relationship between the frequency of usie of specific features of insulin pumps (non-sensor augmented or sensor-augmented) and glycemic control was analyzed. RESULTS: Mean HbA1c in the group was 7.5 ± .8%. Mean daily number of boluses administered was 5.1 ± 1.8, with 75.4% of them being bolus wizards (BW). Daily number of boluses was significantly greater in patients with HbA1c <7.5% than in those with HbA1c>7.5% (5.3 ± 1.6 vs. 4.3 ± 1.6, P=.056). There was a trend to greater use of BW in patients with better control (82.8 ± 21.4% vs. 69.9 ± 29.1%, P=.106). HbA1c was lower in patients using CGM (n=8) as compared to those not using sensor-augmented pumps (7.6 ± .8 vs 7.1 ± .7, P=.067), but the difference was not statistically significant. CONCLUSIONS: More frequent use of BW appears to be associated to better metabolic control in patients with T1DM using pump therapy. In standard clinical practice, augmentation of insulin pump with CGM may be associated to improved glycemic control.


Assuntos
Automonitorização da Glicemia/estatística & dados numéricos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Software , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Sistemas Computacionais , Diabetes Mellitus Tipo 1/sangue , Relação Dose-Resposta a Droga , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Bombas de Infusão Implantáveis , Infusões Subcutâneas , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Design de Software , Resultado do Tratamento , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA