Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
NMR Biomed ; 35(10): e4777, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35633068

RESUMO

Myocardial lipomatous metaplasia, which can serve as substrate for ventricular arrhythmias, is usually composed of regions in which there is an admixture of fat and nonfat tissue. Although dedicated sequences for the detection of fat are available, it would be time-consuming and burdensome to routinely use these techniques to image the entire heart of all patients as part of a typical cardiac MRI exam. Conventional steady-state free-precession (SSFP) cine imaging is insensitive to detecting myocardial regions with partial fatty infiltration. We developed an optimization process for SSFP imaging to set fat signal consistently "out-of-phase" with water throughout the heart, so that intramyocardial regions with partial volume fat would be detected as paradoxically dark regions. The optimized SSFP sequence was evaluated using a fat phantom, through simulations, and in 50 consecutive patients undergoing clinical cardiac MRI. Findings were validated using standard Dixon gradient-recalled-echo (GRE) imaging as the reference. Phantom studies of test tubes with diverse fat concentrations demonstrated good agreement between measured signal intensity and simulated values calculated using Bloch equations. In patients, a line of signal cancellation at the interface between myocardium and epicardial fat was noted in all cases, confirming that SSFP images were consistently out-of-phase throughout the entire heart. Intramyocardial dark regions identified on out-of-phase SSFP images were entirely dark throughout in 33 patients (66%) and displayed an India-ink pattern in 17 (34%). In all cases, dark intramyocardial regions were also seen in the same locations on out-of-phase GRE and were absent on in-phase GRE, confirming that these regions represent areas with partial fat. In conclusion, if appropriately optimized, SSFP cine imaging allows for consistent detection of myocardial fatty metaplasia in patients undergoing routine clinical cardiac MRI without the need for additional image acquisitions using dedicated fat-specific sequences.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Metaplasia , Imagens de Fantasmas
2.
J Chem Phys ; 131(20): 204510, 2009 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-19947697

RESUMO

A recent quantum computing paper (G. S. Uhrig, Phys. Rev. Lett. 98, 100504 (2007)) analytically derived optimal pulse spacings for a multiple spin echo sequence designed to remove decoherence in a two-level system coupled to a bath. The spacings in what has been called a "Uhrig dynamic decoupling (UDD) sequence" differ dramatically from the conventional, equal pulse spacing of a Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo sequence. The UDD sequence was derived for a model that is unrelated to magnetic resonance, but was recently shown theoretically to be more general. Here we show that the UDD sequence has theoretical advantages for magnetic resonance imaging of structured materials such as tissue, where diffusion in compartmentalized and microstructured environments leads to fluctuating fields on a range of different time scales. We also show experimentally, both in excised tissue and in a live mouse tumor model, that optimal UDD sequences produce different T(2)-weighted contrast than do CPMG sequences with the same number of pulses and total delay, with substantial enhancements in most regions. This permits improved characterization of low-frequency spectral density functions in a wide range of applications.


Assuntos
Meios de Contraste , Reforma dos Serviços de Saúde/ética , Reforma dos Serviços de Saúde/métodos , Imageamento por Ressonância Magnética/tendências , Espectroscopia de Ressonância Magnética/métodos , Animais , Meios de Contraste/química , Reforma dos Serviços de Saúde/organização & administração , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA