Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Endosc ; 38(5): 2805-2816, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38594365

RESUMO

BACKGROUND: Indocyanine green fluorescence angiography (ICG-FA) may reduce perfusion-related complications of gastrointestinal anastomosis. Software implementations for quantifying ICG-FA are emerging to overcome a subjective interpretation of the technology. Comparison between quantification algorithms is needed to judge its external validity. This study aimed to measure the agreement for visceral perfusion assessment between two independently developed quantification software implementations. METHODS: This retrospective cohort analysis included standardized ICG-FA video recordings of patients who underwent esophagectomy with gastric conduit reconstruction between August 2020 until February 2022. Recordings were analyzed by two quantification software implementations: AMS and CPH. The quantitative parameter used to measure visceral perfusion was the normalized maximum slope derived from fluorescence time curves. The agreement between AMS and CPH was evaluated in a Bland-Altman analysis. The relation between the intraoperative measurement of perfusion and the incidence of anastomotic leakage was determined for both software implementations. RESULTS: Seventy pre-anastomosis ICG-FA recordings were included in the study. The Bland-Altman analysis indicated a mean relative difference of + 58.2% in the measurement of the normalized maximum slope when comparing the AMS software to CPH. The agreement between AMS and CPH deteriorated as the magnitude of the measured values increased, revealing a proportional (linear) bias (R2 = 0.512, p < 0.001). Neither the AMS nor the CPH measurements of the normalized maximum slope held a significant relationship with the occurrence of anastomotic leakage (median of 0.081 versus 0.074, p = 0.32 and 0.041 vs 0.042, p = 0.51, respectively). CONCLUSION: This is the first study to demonstrate technical differences in software implementations that can lead to discrepancies in ICG-FA quantification in human clinical cases. The possible variation among software-based quantification methods should be considered when interpreting studies that report quantitative ICG-FA parameters and derived thresholds, as there may be a limited external validity.


Assuntos
Algoritmos , Fístula Anastomótica , Angiofluoresceinografia , Verde de Indocianina , Software , Humanos , Estudos Retrospectivos , Angiofluoresceinografia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fístula Anastomótica/etiologia , Fístula Anastomótica/diagnóstico , Fístula Anastomótica/diagnóstico por imagem , Esofagectomia/efeitos adversos , Anastomose Cirúrgica/métodos , Corantes , Vísceras/irrigação sanguínea
2.
Surg Endosc ; 37(8): 6343-6352, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37208482

RESUMO

BACKGROUND: Intraoperative perfusion assessment with indocyanine green fluorescence angiography (ICG-FA) may reduce postoperative anastomotic leakage rates after esophagectomy with gastric conduit reconstruction. This study evaluated quantitative parameters derived from fluorescence time curves to determine a threshold for adequate perfusion and predict postoperative anastomotic complications. METHODS: This prospective cohort study included consecutive patients who underwent FA-guided esophagectomy with gastric conduit reconstruction between August 2020 and February 2022. After intravenous bolus injection of 0.05-mg/kg ICG, fluorescence intensity was registered over time by PINPOINT camera (Stryker, USA). Fluorescent angiograms were quantitatively analyzed at a region of interest of 1 cm diameter at the anastomotic site on the conduit using tailor-made software. Extracted fluorescence parameters were both inflow (T0, Tmax, Fmax, slope, Time-to-peak) as outflow parameters (T90% and T80%). Anastomotic complications including anastomotic leakage (AL) and strictures were documented. Fluorescence parameters in patients with AL were compared to those without AL. RESULTS: One hundred and three patients (81 male, 65.7 ± 9.9 years) were included, the majority of whom (88%) underwent an Ivor Lewis procedure. AL occurred in 19% of patients (n = 20/103). Both time to peak as Tmax were significantly longer for the AL group in comparison to the non-AL group (39 s vs. 26 s, p = 0.04 and 65 vs. 51 s, p = 0.03, respectively). Slope was 1.0 (IQR 0.3-2.5) and 1.7 (IQR 1.0-3.0) for the AL and non-AL group (p = 0.11). Outflow was longer in the AL group, although not significantly, T90% 30 versus 15 s, respectively, p = 0.20). Univariate analysis indicated that Tmax might be predictive for AL, although not reaching significance (p = 0.10, area under the curve 0.71) and a cut-off value of 97 s was derived, with a specificity of 92%. CONCLUSION: This study demonstrated quantitative parameters and identified a fluorescent threshold which could be used for intraoperative decision-making and to identify high-risk patients for anastomotic leakage during esophagectomy with gastric conduit reconstruction. A significant predictive value remains to be determined in future studies.


Assuntos
Fístula Anastomótica , Esofagectomia , Humanos , Masculino , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/cirurgia , Esofagectomia/métodos , Estudos Prospectivos , Verde de Indocianina , Estômago/cirurgia , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Corantes , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Angiofluoresceinografia/métodos , Perfusão
3.
Tech Coloproctol ; 27(4): 281-290, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36129594

RESUMO

BACKGROUND: Intraoperative fluorescence angiography (FA) is of potential added value during ileal pouch-anal anastomosis (IPAA), especially after vascular ligation as part of lengthening measures. In this study, time to fluorescent enhancement during FA was evaluated in patients with or without vascular ligation during IPAA. METHODS: This is a retrospective cohort study of all consecutive patients that underwent FA-guided IPAA between August 2018 and December 2019 in our tertiary referral centre. Vascular ligation was defined as disruption of the ileocolic arcade or ligation of interconnecting terminal ileal branches. FA was performed before and after ileoanal anastomotic reconstruction. During FA, time to fluorescent enhancement was recorded at different sites of the pouch. RESULTS: Thirty-eight patients [55.3% male, median age 45 years (IQR 24-51 years)] were included, of whom the majority (89.5%) underwent a modified-2-stage restorative proctocolectomy. Vascular ligation was performed in 15 patients (39.5%), and concerned central ligation of the ileocolic arcade in 3 cases, interconnecting branches in 10, and a combination in 2. For the entire cohort, time between indocyanine green (ICG) injection and first fluorescent signal in the pouch was 20 s (IQR 15-31 s) before and 25 s (IQR 20-36 s) after anal anastomotic reconstruction. Time from ICG injection to the first fluorescent signal at the inlet, anvil and blind loop of the pouch were non-significantly prolonged in patients that received vascular ligation. CONCLUSIONS: Results from this study indicate that time to fluorescence enhancement during FA might be prolonged due to arterial rerouting through the arcade or venous outflow obstruction in case of vascular ligation.


Assuntos
Colite Ulcerativa , Bolsas Cólicas , Proctocolectomia Restauradora , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Proctocolectomia Restauradora/métodos , Estudos Retrospectivos , Anastomose Cirúrgica , Íleo/cirurgia , Perfusão , Colite Ulcerativa/cirurgia , Complicações Pós-Operatórias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA