Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Comp Eff Res ; 13(3): e230174, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38294332

RESUMO

Aim: Clinical trials and real-world data for Type II diabetes both show that glycated hemoglobin (HbA1c) levels and hypoglycemia occurrence can be reduced by real-time continuous glucose monitoring (rt-CGM) versus self-monitoring of blood glucose (SMBG). The present cost-utility study investigated the long-term health economic outcomes associated with using rt-CGM versus SMBG in people with insulin-treated Type II diabetes in France. Materials & methods: Effectiveness data were obtained from a real-world study, which showed rt-CGM reduced HbA1c by 0.56% (6.1 mmol/mol) versus sustained SMBG. Analyses were conducted using the IQVIA Core Diabetes Model. A French payer perspective was adopted over a lifetime horizon for a cohort aged 64.5 years with baseline HbA1c of 8.3% (67 mmol/mol). A willingness-to-pay threshold of €147,093 was used, and future costs and outcomes were discounted at 4% annually. Results: The analysis projected quality-adjusted life expectancy was 8.50 quality-adjusted life years (QALYs) for rt-CGM versus 8.03 QALYs for SMBG (difference: 0.47 QALYs), while total mean lifetime costs were €93,978 for rt-CGM versus €82,834 for SMBG (difference: €11,144). This yielded an incremental cost-utility ratio (ICUR) of €23,772 per QALY gained for rt-CGM versus SMBG. Results were particularly sensitive to changes in the treatment effect (i.e., change in HbA1c), annual price and quality of life benefit associated with rt-CGM, SMBG frequency, baseline patient age and complication costs. Conclusion: The use of rt-CGM is likely to be cost-effective versus SMBG for people with insulin-treated Type II diabetes in France.


Assuntos
Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/uso terapêutico , Glicemia/análise , Automonitorização da Glicemia/métodos , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Monitoramento Contínuo da Glicose , Qualidade de Vida , Análise Custo-Benefício , Expectativa de Vida , França
2.
Cardiovasc Diabetol ; 23(1): 22, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195491

RESUMO

BACKGROUND: Myocardial infarction (MI), stroke, peripheral arterial disease (PAD), heart failure (HF) and chronic kidney disease (CKD) are common cardiovascular renal diseases (CVRD) manifestations for type 2 diabetes. The objective was to estimate the incidence of the first occurring CVRD manifestation and cumulative hospitalization costs of each CVRD manifestation for type 2 diabetes without CVRD history. METHODS: A cohort study of all type 2 diabetes free of CVRD as of January 1st 2014, was identified and followed-up for 5 years within the French SNDS nationwide claims database. The cumulative incidence of the first occurring CVRD manifestation was estimated using the cumulative incidence function, with death as a competing risk. Cumulative hospitalization costs of each CVRD manifestations were estimated from the perspective of all payers. RESULTS: From 2,079,089 type 2 diabetes without cancer or transplantation, 76.5% were free of CVRD at baseline with a mean age of 65 years, 52% of women and 7% with microvascular complications history. The cumulative incidence of a first CVRD manifestation was 15.3% after 5 years of follow-up with a constant linear increase over time for all CVRD manifestations: The most frequent was CKD representing 40.6% of first occurred CVRD manifestation, followed by HF (23.0%), then PAD (13.5%), stroke (13.2%) and MI (9.7%). HF and CKD together reached about one patient out of ten after 5 years and represented 63.6% of first CVRD manifestations. The 5-year global cost of all CVRD hospitalizations was 3.9 billion euros (B€), i.e. 2,450€ per patient of the whole cohort, with an exponential increase over time for each specific CVRD manifestation. The costliest was CKD (2.0 B€), followed by HF (1.2 B€), then PAD (0.7 B€), stroke (0.6 B€) and MI (0.3 B€). CONCLUSIONS/INTERPRETATION: While MI, stroke and PAD remain classic major risks of complications for CVRD-free type 2 diabetes, HF and CKD nowadays represent individually a higher risk and cost than each of these classic manifestations, and jointly represents a risk and a cost twice as high as these three classic manifestations all together. This should encourage the development of specific HF and CKD preventive strategies.


Assuntos
Diabetes Mellitus Tipo 2 , Cardiopatias , Insuficiência Cardíaca , Hipertensão Renal , Infarto do Miocárdio , Doença Arterial Periférica , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Incidência , Estudos de Coortes , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/terapia
3.
Diabetes Ther ; 14(2): 303-318, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36422803

RESUMO

INTRODUCTION: The use of devices to connect insulin pens could facilitate management and improve glycaemic control in people with type 1 (PwT1D) and type 2 diabetes (PwT2D). However, their acceptance seems little studied. We conducted an online survey with the main objective of assessing the level of interest among insulin-treated people with diabetes (PwD) in a device connected to a disposable pen and secondary objectives of assessing the perceived benefits and important features expected of a connected device and identifying factors associated with interest scores. METHODS: An ad-hoc questionnaire, validated by PwD, was used. Responses from 1798 PwD (975 PwT1D and 823 PwT2D) were analysed. RESULTS: The mean interest rating was 7.4/10 (PwT1D: 7.2 vs PwT2D: 7.7; p < 0.001). PwD perceived that the device would make it easier to record their diabetes-related information (7.7/10) and keep all insulin and diabetes data in a single location (7.7/10). It was particularly important for PwD that this type of device could integrate data from glucose-measuring devices (7.8/10) and could set an alarm when all insulin in the body had been metabolised (7.7/10). CONCLUSION: Our study highlighted PwD's strong interest in automating the collection of their insulin therapy data, with significantly more interest among PwT2D than PwT1D, and the importance of interoperability between glucose measurement devices and interchangeability between the different brands of insulin. More generally, for the first time and on a large scale, our study provided a greater understanding of the expectations of PwD regarding these devices.

4.
J Diabetes Sci Technol ; 13(6): 1161-1168, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30862245

RESUMO

Benefits of telemedicine have been proven in the field of diabetes. Among a number of technical solutions, Diabeo® has been studied in both type 1 and type 2 diabetes with intensive insulin therapy. This digital therapeutic system contains a self-monitoring glucose logbook and offers automated insulin dose recommendations thanks to a fully customizable algorithm. In addition, the cloud-based dedicated software also has features to facilitate remote monitoring, including a platform for diabetes nurses who perform coaching and treatment adjustment. A detailed description of this telemedicine system is provided, as well as results of completed clinical studies. In particular, TeleDiab 1's positive results on HbA1c in type 1 diabetes are detailed. We conclude with a discussion of the role of this telemedicine system within the landscape of mobile apps for diabetes.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Telemedicina/métodos , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Pessoal de Saúde , Humanos , Aplicativos Móveis
5.
Eur J Nucl Med Mol Imaging ; 43(2): 288-295, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26280980

RESUMO

PURPOSE: Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of (15)O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using (15)O-water PET. METHODS: We retrospectively processed 70 consecutive (15)O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. RESULTS: Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. CONCLUSION: Non-attenuation-corrected (15)O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Endotélio Vascular/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA