Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Front Cardiovasc Med ; 8: 743849, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34712713

RESUMO

Background: Coronary autoregulation is a feedback system, which maintains near-constant myocardial blood flow over a range of mean arterial pressure (MAP). Yet in emergency or peri-operative situations, hypotensive or hypertensive episodes may quickly arise. It is not yet established how rapid blood pressure changes outside of the autoregulation zone (ARZ) impact left (LV) and right ventricular (RV) function. Using cardiovascular magnetic resonance (CMR) imaging, measurements of myocardial tissue oxygenation and ventricular systolic and diastolic function can comprehensively assess the heart throughout a range of changing blood pressures. Design and methods: In 10 anesthetized swine, MAP was varied in steps of 10-15 mmHg from 29 to 196 mmHg using phenylephrine and urapidil inside a 3-Tesla MRI scanner. At each MAP level, oxygenation-sensitive (OS) cine images along with arterial and coronary sinus blood gas samples were obtained and blood flow was measured from a surgically implanted flow probe on the left anterior descending coronary artery. Using CMR feature tracking-software, LV and RV circumferential systolic and diastolic strain parameters were measured from the myocardial oxygenation cines. Results: LV and RV peak strain are compromised both below the lower limit (LV: Δ1.2 ± 0.4%, RV: Δ4.4 ± 1.2%, p < 0.001) and above the upper limit (LV: Δ2.1 ± 0.4, RV: Δ5.4 ± 1.4, p < 0.001) of the ARZ in comparison to a baseline of 70 mmHg. LV strain demonstrates a non-linear relationship with invasive and non-invasive measures of oxygenation. Specifically for the LV at hypotensive levels below the ARZ, systolic dysfunction is related to myocardial deoxygenation (ß = -0.216, p = 0.036) in OS-CMR and both systolic and diastolic dysfunction are linked to reduced coronary blood flow (peak strain: ß = -0.028, p = 0.047, early diastolic strain rate: ß = 0.026, p = 0.002). These relationships were not observed at hypertensive levels. Conclusion: In an animal model, biventricular function is compromised outside the coronary autoregulatory zone. Dysfunction at pressures below the lower limit is likely caused by insufficient blood flow and tissue deoxygenation. Conversely, hypertension-induced systolic and diastolic dysfunction points to high afterload as a cause. These findings from an experimental model are translatable to the clinical peri-operative environment in which myocardial deformation may have the potential to guide blood pressure management, in particular at varying individual autoregulation thresholds.

2.
ESC Heart Fail ; 7(5): 2637-2649, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32686332

RESUMO

AIMS: Heart failure with preserved ejection fraction is still a diagnostic and therapeutic challenge, and accurate non-invasive diagnosis of left ventricular (LV) diastolic dysfunction (DD) remains difficult. The current study aimed at identifying the most informative cardiovascular magnetic resonance (CMR) parameters for the assessment of LVDD. METHODS AND RESULTS: We prospectively included 50 patients and classified them into three groups: with DD (DD+, n = 15), without (DD-, n = 26), and uncertain (DD±, n = 9). Diagnosis of DD was based on echocardiographic E/E', invasive LV end-diastolic pressure, and N-terminal pro-brain natriuretic peptide. CMR was performed at 1.5 T to assess LV and left atrial (LA) morphology, LV diastolic strain rate (SR) by tissue tracking and tagging, myocardial peak velocities by tissue phase mapping, and transmitral inflow profile using phase contrast techniques. Statistics were performed only on definitive DD+ and DD- (total number 41). DD+ showed enlarged LA with LA end-diastolic volume/height performing best to identify DD+ with a cut-off value of ≥0.52 mL/cm (sensitivity = 0.71, specificity = 0.84, and area under the receiver operating characteristic curve = 0.75). DD+ showed significantly reduced radial (inferolateral E peak: DD-: -14.5 ± 6.5%/s vs. DD+: -10.9 ± 5.9%/s, P = 0.04; anterolateral A peak: DD-: -4.2 ± 1.6%/s vs. DD+: -3.1 ± 1.4%/s, P = 0.04) and circumferential (inferolateral A peak: DD-: 3.8 ± 1.2%/s vs. DD+: 2.8 ± 0.8%/s, P = 0.007; anterolateral A peak: DD-: 3.5 ± 1.2%/s vs. DD+: 2.5 ± 0.8%/s, P = 0.048) SR in the basal lateral wall assessed by tissue tracking. In the same segments, DD+ showed lower peak myocardial velocity by tissue phase mapping (inferolateral radial peak: DD-: -3.6 ± 0.7 ms vs. DD+: -2.8 ± 1.0 ms, P = 0.017; anterolateral longitudinal peak: DD-: -5.0 ± 1.8 ms vs. DD+: -3.4 ± 1.4 ms, P = 0.006). Tagging revealed reduced global longitudinal SR in DD+ (DD-: 45.8 ± 12.0%/s vs. DD+: 34.8 ± 9.2%/s, P = 0.022). Global circumferential and radial SR by tissue tracking and tagging, LV morphology, and transmitral flow did not differ between DD+ and DD-. CONCLUSIONS: Left atrial size and regional quantitative myocardial deformation applying CMR identified best patients with DD.


Assuntos
Disfunção Ventricular Esquerda , Diástole , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem
3.
Magn Reson Med ; 77(6): 2153-2166, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27343201

RESUMO

PURPOSE: Achieving higher spatial resolution and improved brain coverage while mitigating in-plane susceptibility artifacts in the assessment of perfusion parameters, such as cerebral blood volume, in echo planar imaging (EPI)-based dynamic susceptibility contrast weighted cerebral perfusion measurements. METHODS: PEAK-EPI, an EPI sequence with interleaved readout trajectories and three different strategies for autocalibration-signal acquisition (inplace, dynamic extra and extra) is presented. Performance of each approach is analyzed in vivo based on flip angle variation induced dynamics, assessing temporal fidelity, temporal SNR and g-factors. All approaches are compared with conventional GRAPPA reconstructions. PEAK-EPI with inplace autocalibration-signal at R = 5 is then compared with the standard clinical EPI protocol in six patients, using two half-dose dynamic susceptibility contrast weighted cerebral perfusion measurements per subject. RESULTS: PEAK-EPI acquisition facilitates a substantial increase of spatial resolution at a higher number of slices per TR and provides improved SNR compared to conventional GRAPPA. High dependency of the resulting reconstruction quality on the type of autocalibration-signal acquisition is observed. PEAK-EPI with inplace autocalibration-signal achieves high temporal fidelity and initial feasibility is shown. CONCLUSION: The obtained high resolution cerebral blood volume maps reveal more detailed information than in corresponding standard EPI measurements and facilitate detailed delineation of tumorous tissue. Magn Reson Med 77:2153-2166, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Algoritmos , Circulação Cerebrovascular , Humanos , Masculino , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
4.
Eur Heart J Cardiovasc Imaging ; 17(4): 458-66, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26219296

RESUMO

AIMS: To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). METHODS AND RESULTS: In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. CONCLUSION: The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Diástole , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Masculino , Cuidados Pré-Operatórios , Estudos Prospectivos , Sístole , Substituição da Valva Aórtica Transcateter
5.
MAGMA ; 28(2): 149-59, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25099493

RESUMO

OBJECTIVE: We sought to evaluate the feasibility of k-t parallel imaging for accelerated 4D flow MRI in the hepatic vascular system by investigating the impact of different acceleration factors. MATERIALS AND METHODS: k-t GRAPPA accelerated 4D flow MRI of the liver vasculature was evaluated in 16 healthy volunteers at 3T with acceleration factors R = 3, R = 5, and R = 8 (2.0 × 2.5 × 2.4 mm(3), TR = 82 ms), and R = 5 (TR = 41 ms); GRAPPA R = 2 was used as the reference standard. Qualitative flow analysis included grading of 3D streamlines and time-resolved particle traces. Quantitative evaluation assessed velocities, net flow, and wall shear stress (WSS). RESULTS: Significant scan time savings were realized for all acceleration factors compared to standard GRAPPA R = 2 (21-71 %) (p < 0.001). Quantification of velocities and net flow offered similar results between k-t GRAPPA R = 3 and R = 5 compared to standard GRAPPA R = 2. Significantly increased leakage artifacts and noise were seen between standard GRAPPA R = 2 and k-t GRAPPA R = 8 (p < 0.001) with significant underestimation of peak velocities and WSS of up to 31 % in the hepatic arterial system (p <0.05). WSS was significantly underestimated up to 13 % in all vessels of the portal venous system for k-t GRAPPA R = 5, while significantly higher values were observed for the same acceleration with higher temporal resolution in two veins (p < 0.05). CONCLUSION: k-t acceleration of 4D flow MRI is feasible for liver hemodynamic assessment with acceleration factors R = 3 and R = 5 resulting in a scan time reduction of at least 40 % with similar quantitation of liver hemodynamics compared with GRAPPA R = 2.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Circulação Hepática/fisiologia , Fígado/fisiologia , Angiografia por Ressonância Magnética/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Fígado/anatomia & histologia , Reprodutibilidade dos Testes , Técnicas de Imagem de Sincronização Respiratória/métodos , Sensibilidade e Especificidade , Resistência ao Cisalhamento/fisiologia
6.
J Magn Reson Imaging ; 38(5): 1054-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23908094

RESUMO

PURPOSE: To evaluate spatiotemporal parallel imaging with R = 5 in comparison to conventional parallel imaging with R = 2 applied to phase contrast (PC) magnetic resonance imaging (MRI). This was motivated by the fact that scan times for PC imaging often exceed breath-hold capabilities of patients even with standard parallel imaging using typical reduction factors of R = 2. MATERIALS AND METHODS: K-t generalized autocalibrating partially parallel acquisition (GRAPPA) acquisition was validated in phantom measurements and then applied in 10 volunteer and three patient examinations. Due to the higher reduction factor compared to conventional GRAPPA, k-t GRAPPA measurements could be performed during breath-hold with high spatial and temporal resolution. K-t GRAPPA scans were compared to GRAPPA acquired during free-breathing with navigator respiration control. In addition, spatiotemporally accelerated PC imaging was acquired during free-breathing for comparison of k-t-accelerated breath-held scans. RESULTS: Substantial improvements in image quality for the breath-hold measurements were observed. Significantly reduced peak velocities were found for the GRAPPA protocol compared to the k-t-accelerated breath-hold scans for both flow (8%) and myocardial motion (up to 30%) measurements. CONCLUSION: Spatiotemporal acceleration allows the performance of high temporal or spatial resolution PC imaging during breath-hold while providing high image quality and robust acquisition of functional information that cannot be achieved during breath-hold with standard techniques.


Assuntos
Algoritmos , Artefatos , Suspensão da Respiração , Circulação Coronária/fisiologia , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espaço-Temporal
7.
J Magn Reson Imaging ; 25(4): 824-31, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17345635

RESUMO

PURPOSE: To evaluate an improved image acquisition and data-processing strategy for assessing aortic vascular geometry and 3D blood flow at 3T. MATERIALS AND METHODS: In a study with five normal volunteers and seven patients with known aortic pathology, prospectively ECG-gated cine three-dimensional (3D) MR velocity mapping with improved navigator gating, real-time adaptive k-space ordering and dynamic adjustment of the navigator acceptance criteria was performed. In addition to morphological information and three-directional blood flow velocities, phase-contrast (PC)-MRA images were derived from the same data set, which permitted 3D isosurface rendering of vascular boundaries in combination with visualization of blood-flow patterns. RESULTS: Analysis of navigator performance and image quality revealed improved scan efficiencies of 63.6%+/-10.5% and temporal resolution (<50 msec) compared to previous implementations. Semiquantitative evaluation of image quality by three independent observers demonstrated excellent general image appearance with moderate blurring and minor ghosting artifacts. Results from volunteer and patient examinations illustrate the potential of the improved image acquisition and data-processing strategy for identifying normal and pathological blood-flow characteristics. CONCLUSION: Navigator-gated time-resolved 3D MR velocity mapping at 3T in combination with advanced data processing is a powerful tool for performing detailed assessments of global and local blood-flow characteristics in the aorta to describe or exclude vascular alterations.


Assuntos
Aorta Abdominal/fisiologia , Aorta Torácica/fisiologia , Aumento da Imagem , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Adulto , Idoso , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/patologia , Aorta Torácica/anatomia & histologia , Aorta Torácica/patologia , Doenças da Aorta/patologia , Doenças da Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA