1.
Clin Hemorheol Microcirc ; 86(3): 263-273, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38489171

RESUMO

BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Técnicas de Imagem por Elasticidade/métodos , Meios de Contraste , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Viscosidade , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia/métodos
2.
Life (Basel) ; 10(9)2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-32867158

RESUMO

BACKGROUND: After application of iodinated contrast media (CM), a pronounced deterioration of the microcirculation in skin and myocardium was reported. Clinically, the repeated application of CM, especially, led to an increase of the renal resistance index (RRI). With respect to the transiency of the RRI increase, it is reasonable to assume that the deterioration of blood flow could be due to transient blood stasis caused by reversible morphologic cell alterations due to osmotic discrepancies between CM and human blood. Therefore, the hypothesis was investigated whether CM are able to induce in vivo such blood stasis and cell deformations in the renal vasculature of well-hydrated pigs. METHODS: The in vivo study was performed as a prospective randomized examination to compare the effects of two different CM in 16 pigs (German Landrace). Pigs were randomized to receive either Iodixanol (n = 8), or Iopromide (n = 8). Each animal received 10 injections separated by 5-min intervals via the suprarenal aorta at a rate of 10 mL/s according to the usual procedure during a cardiac catheter examination. Finally, the kidneys were explanted and processed for histology (H & E staining and fibrin staining according to Weigert) as well as for scanning electron microscopy (SEM) with regards to morphologic correlates explaining the changes in the microcirculation. RESULTS: In each of the predefined four categories of vascular diameters, blood stasis were found, but clearly more often after application of Iopromide than after application of Iodixanol (p < 0.001). In addition, Iopromide induced more blood stasis in all of the examined kidney regions compared to Iodixanol (p = 0.0001). There were no obstructive events in the middle cortex following the application of Iodixanol. Except for the region around a puncture channel of a placed-in catheter probe, no fibrin was detected in Weigert's fibrin-stained samples, neither around the histologically assessed thrombi nor in vessels with blood stasis. Complementary SEM analyses revealed in a few cases only a slight generation of fibrin and thrombi and deformations, such as echinocyte and "box-like" deformations. CONCLUSIONS: According to previous in vitro studies, pathological erythrocyte deformations, such as echinocyte and box-like formation of erythrocytes, were observed also in vivo. In addition, blood stasis and/or thrombi could be detected in histological samples from explanted kidneys from young pigs after repeated in vivo administration of CM. In only a few cases, mural platelet aggregates within minimal fibrin meshes occurred only after the application of Iopromide.

3.
J Tissue Eng Regen Med ; 11(4): 1034-1044, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-25712330

RESUMO

Poly(ether imide) (PEI), which can be chemically functionalized with biologically active ligands, has emerged as a potential biomaterial for medical implants. Electrospun PEI scaffolds have shown advantageous properties, such as enhanced endothelial cell adherence, proliferation and low platelet adhesion in in vitro experiments. In this study, the in vivo behaviour of electrospun PEI scaffolds and PEI films was examined in a murine subcutaneous implantation model. Electrospun PEI scaffolds and films were surgically implanted subcutaneously in the dorsae of mice. The surrounding subcutaneous tissue response was examined via histopathological examination at 7 and 28 days after implantation. No serious adverse events were observed for both types of PEI implants. The presence of macrophages or foreign body giant cells in the vicinity of the implants and the formation of a fibrous capsule indicated a normal foreign body reaction towards PEI films and scaffolds. Capsule thickness and inflammatory infiltration cells significantly decreased for PEI scaffolds during days 7-28 while remaining unchanged for PEI films. The infiltration of cells into the implant was observed for PEI scaffolds 7 days after implantation and remained stable until 28 days of implantation. Additionally some, but not all, PEI scaffold implants induced the formation of functional blood vessels in the vicinity of the implants. Conclusively, this study demonstrates the in vivo biocompatibility of PEI implants, with favourable properties of electrospun PEI scaffolds regarding tissue integration and wound healing. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Materiais Biocompatíveis/farmacologia , Polímeros/farmacologia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/química , Reação a Corpo Estranho/patologia , Inflamação/patologia , Macrófagos/citologia , Macrófagos/efeitos dos fármacos , Teste de Materiais , Camundongos Endogâmicos C57BL , Neovascularização Fisiológica/efeitos dos fármacos , Polímeros/química , Temperatura
4.
Semin Thromb Hemost ; 31(4): 464-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16149025

RESUMO

In 1974, Wu and Hoak described a method for determining circulating platelet aggregates. This method was modified by Grotemeyer in 1983. The platelet reactivity index (PR) is based on the ratio of platelet aggregates in blood samples obtained in different buffer solutions. Platelet aggregates are resolved when blood is sampled in EDTA-buffer, but remain fixed when EDTA-formalin-buffer is used. Generally, the PR is preferred, because in vitro manipulations of platelets are not necessary, and the results are calculated. PR values above 1.05 are suspicious for elevated platelet aggregation. PR values above 1.2 indicate pathological changes in platelet aggregation. The PR is inexpensive (4.0 euro dollars) and rapid to perform. PR values were used successfully to identify nonresponders to secondary prophylaxis with acetylsalicylic acid (ASA), that is, patients suffering from stroke (33%) and patients after cardiac ischemia (18%). Furthermore, elevated PR values correlated significantly with the incidence of arterial thromboembolic complications. The PR correlated well in our prospective study with values received from the retention test Homburg (RT-H) and the platelet function analyzer (PFA-100). The data indicate that the values of the PR seem to be highly predictive for the evaluation of the ASA therapy. However, the PR is not feasible for the determination of the ASA overdosage.


Assuntos
Plaquetas/efeitos dos fármacos , Monitoramento de Medicamentos/métodos , Inibidores da Agregação Plaquetária/farmacologia , Testes de Função Plaquetária/métodos , Aspirina/farmacologia , Ensaios Clínicos como Assunto , Ácido Edético/farmacologia , Feminino , Citometria de Fluxo , Formaldeído/farmacologia , Humanos , Ativação Plaquetária , Adesividade Plaquetária , Agregação Plaquetária , Contagem de Plaquetas , Testes de Função Plaquetária/economia , Testes de Função Plaquetária/instrumentação , Gravidez , Estudos Prospectivos , Tromboembolia , Fatores de Tempo