Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Ann Work Expo Health ; 68(2): 217-221, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38156670

RESUMO

Sulfuric acid, a constituent of lead-acid batteries, is an extremely hazardous substance, necessitating utmost caution. Unfortunately, many workers that utilize battery-operated equipment remain unaware of the potential exposure. This study aims to evaluate the potential exposure to sulfuric acid among workers employed by small companies associated with the operation of floor cleaning equipment powered by lead-acid batteries. Only cleaning equipment (hand-push and ride-on types) that required supplementation of lead-acid batteries with distilled water were targeted. Exposure measurement and analysis were performed according to the guidelines of NIOSH and including personal sampling and stationary sampling on the equipment. Exposure measurements indicated that workers were exposed to sulfuric acid. Additionally, the concentration level was slightly elevated in the stationary samples compared to personal samples. This study affirms that workers can experience exposure to sulfuric acid, even in the absence of direct handling of the substance. Consequently, there is a need to recognize and mitigate the potential risks.


Assuntos
Exposição Ocupacional , Humanos , Substâncias Perigosas , Ácidos Sulfúricos/análise
2.
Neurospine ; 20(4): 1205-1216, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38171289

RESUMO

OBJECTIVE: Although several studies have reported successful fusion rates after oblique lumbar interbody fusion (OLIF) using allografts or dimerized bone matrix (DBM) instead of autografts, whether OLIF can achieve satisfactory solid fusion without the use of autografts remains unclear. This study investigated the real fusion rates after OLIF using allografts and DBM, which were evaluated using both dynamic radiographs and computed tomography scans. METHODS: We enrolled 79 consecutive patients who underwent minimally invasive OLIF followed by percutaneous pedicle screw fixation. All patients were treated with OLIF between L2 and L5 and underwent radiographic and clinical follow-ups at 12, 18, and 24 months after surgery. Radiographic assessment of fusion was performed using the modified BrantigaSteffee-Fraser (mBSF) scale, which was categorized as follows: grades I (radiographic pseudoarthrosis), II (indeterminate fusion), and III (solid radiographic fusion). Other radiologic and clinical outcomes were evaluated using the following parameters: vertebral slippage distance, disc height, subsidence, Oswestry Disability Index (ODI), and visual analogue scale (VAS). RESULTS: Clinical outcomes demonstrated significant improvements in the VAS scores for back pain, leg pain, and ODI after surgery. Subsidence was present in 34 cases (35.4%) at 12 months postoperatively, which increased to 47.9% and reached 50.0% at 1.5 years and 2 years after surgery, respectively. The solid fusion rate after OLIF was 32.3% at 1 year, increased to 58.3% at 1.5 years, and reached 72.9% at 2 years. Radiographic pseudoarthrosis was 24.0% at 1 year, which decreased to 6.3% at 1.5 years and 3.1% at 2 years. CONCLUSION: OLIF is a safe and effective surgical procedure for the treatment of degenerative lumbar diseases. The mBSF scale, which simultaneously evaluates both dynamic angles and bone bridge formation, offers great reliability for the radiological assessment of fusion. Moreover, OLIF using allografts and DBM, which is performed on one or 2 levels at L2-5, can achieve satisfactory fusion rates within 2 years after surgery.

3.
Am J Vet Res ; 82(7): 546-553, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34166084

RESUMO

OBJECTIVE: To investigate radiographic variables for correlation with splenic size as estimated with CT in cats. ANIMALS: 38 healthy adult cats. PROCEDURES: The width and height of the splenic head and total length, segmental length, and width of the spleen were measured on radiographic and CT images obtained from 10 cats in prospective, exploratory experiments. Distance between the splenic head and left kidney, anatomic locations of the head and tail of the spleen, and CT-derived splenic volume were also assessed. Correlation and agreement between radiographic and CT measurements and interobserver agreement for measurements with each method were determined. A retrospective evaluation of radiographs obtained without sedation or anesthesia for 28 cats was performed to establish preliminary guidelines for the measurement deemed the most reliable estimator of splenic size. RESULTS: Radiographic measurements of total and segmental splenic length were significantly correlated with the respective CT measurements and with splenic volume. Agreement between radiographic and CT measurements of segmental length was good; interobserver agreement was excellent for all variables. In retrospective evaluations, median segmental length of the spleen was 57.87 mm (range, 34.72 to 105.44 mm) on radiographs; the caudal border of the splenic head on lateral views was located from the cranial part of L1 to the caudal part of L2, and the caudal border of the splenic tail on ventrodorsal views was located from the caudal part of L2 to the caudal part of L5. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that segmental length of the spleen on radiographs is a reliable estimator of splenic size in healthy cats.


Assuntos
Baço , Tomografia Computadorizada por Raios X , Animais , Gatos , Rim , Estudos Prospectivos , Estudos Retrospectivos , Baço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/veterinária
4.
Sensors (Basel) ; 21(2)2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33419005

RESUMO

This paper proposed a triangular inequality-based rewiring method for the rapidly exploring random tree (RRT)-Connect robot path-planning algorithm that guarantees the planning time compared to the RRT algorithm, to bring it closer to the optimum. To check the proposed algorithm's performance, this paper compared the RRT and RRT-Connect algorithms in various environments through simulation. From these experimental results, the proposed algorithm shows both quicker planning time and shorter path length than the RRT algorithm and shorter path length than the RRT-Connect algorithm with a similar number of samples and planning time.

5.
Am J Vet Res ; 81(2): 122-130, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31985284

RESUMO

OBJECTIVE: To investigate the diagnostic usefulness of split-bolus CT enterography in dogs. ANIMALS: 6 healthy Beagles. PROCEDURES: CT enterography was performed in all dogs in a nonrandomized crossover study design involving 3 techniques: a dual-phase technique and 2 techniques involving splitting of the administered contrast agent dose (ie, split technique and split-bolus tracking technique). For the 2 techniques involving dose splitting (ie, split CT enterography), contrast agent was injected twice, with the first injection consisting of 60% of the total dose, followed by injection of the remaining 40%. Then, a single set of CT images was obtained when the arterial and venous phases matched (dual-phase and split techniques) or when enhancement of the abdominal aorta reached 100 HU (split-bolus tracking technique). Enhancement of the intestinal wall and mesenteric vessels was assessed qualitatively and quantitatively. RESULTS: The total number of images required for interpretation was significantly lower for the split technique than for the dual-phase technique. The amount of time needed to complete CT enterography was significantly less for the split-bolus tracking technique than for the other 2 techniques. For all 3 techniques, adequate contrast enhancement of the mesenteric vessels and intestinal wall was achieved. The split technique provided contrast enhancement of the intestinal wall and mesenteric vessels similar to that provided with the dual-phase technique, whereas contrast enhancement of these structures was lowest for the split-bolus tracking technique. CONCLUSIONS AND CLINICAL RELEVANCE: Split-bolus CT enterography at a contrast agent allocation ratio of 60:40 enabled simultaneous evaluation of the enhanced intestine wall and mesenteric vessels and yielded image quality similar to that of dual-phase CT enterography in healthy dogs.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Abdome , Animais , Estudos Cross-Over , Cães , Intestinos
6.
Langmuir ; 29(2): 701-9, 2013 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-23234496

RESUMO

Oxygen and nutrients cannot be delivered to cells residing in the interior of large-volume scaffolds via diffusion alone. Several efforts have been made to meet the metabolic needs of cells in a scaffold by constructing mass transport channels, particularly in the form of bifurcated networks. In contrast to progress in fabrication technologies, however, an approach to designing an optimal network based on experimental evaluation has not been actively reported. The main objective of this study was to establish a procedure for designing an effective microfluidic network system for a cell-seeded scaffold and to develop an experimental model to evaluate the design. We proposed a process to design a microfluidic network by combining an oxygen transport simulation with biomimetic principles governing biological vascular trees. The simulation was performed with the effective diffusion coefficient (D(e,s)), which was experimentally measured in our previous study. Porous scaffolds containing an embedded microfluidic network were fabricated using the lost mold shape-forming process and salt leaching method. The reliability of the procedure was demonstrated by experiments using the scaffolds. This approach established a practical basis for designing an effective microfluidic network in a cell-seeded scaffold.


Assuntos
Desenho de Equipamento/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Oxigênio/metabolismo , Alicerces Teciduais , Animais , Transporte Biológico , Técnicas de Cultura de Células , Hipóxia Celular , Proliferação de Células , Difusão , Desenho de Equipamento/métodos , Cinética , Camundongos , Modelos Químicos , Células NIH 3T3 , Porosidade , Engenharia Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA