Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Oncotarget ; 8(24): 39774-39781, 2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28427153

RESUMO

The aim of this study is to compare between proton boron fusion therapy (PBFT) and boron neutron capture therapy (BNCT) and to analyze dose escalation using a Monte Carlo simulation. We simulated a proton beam passing through the water with a boron uptake region (BUR) in MCNPX. To estimate the interaction between neutrons/protons and borons by the alpha particle, the simulation yielded with a variation of the center of the BUR location and proton energies. The variation and influence about the alpha particle were observed from the percent depth dose (PDD) and cross-plane dose profile of both the neutron and proton beams. The peak value of the maximum dose level when the boron particle was accurately labeled at the region was 192.4% among the energies. In all, we confirmed that prompt gamma rays of 478 keV and 719 keV were generated by the nuclear reactions in PBFT and BNCT, respectively. We validated the dramatic effectiveness of the alpha particle, especially in PBFT. The utility of PBFT was verified using the simulation and it has a potential for application in radiotherapy.


Assuntos
Terapia por Captura de Nêutron de Boro , Imagens de Fantasmas , Prótons , Simulação por Computador , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica
2.
Phys Med ; 32(10): 1271-1275, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27229367

RESUMO

PURPOSE: The purpose of this study was to verify acquisition feasibility of a single photon emission computed tomography image using prompt gamma rays for proton boron fusion therapy (PBFT) and to confirm an enhanced therapeutic effect of PBFT by comparison with conventional proton therapy without use of boron. METHODS: Monte Carlo simulation was performed to acquire reconstructed image during PBFT. We acquired percentage depth dose (PDD) of the proton beams in a water phantom, energy spectrum of the prompt gamma rays, and tomographic images, including the boron uptake region (BUR; target). The prompt gamma ray image was reconstructed using maximum likelihood expectation maximisation (MLEM) with 64 projection raw data. To verify the reconstructed image, both an image profile and contrast analysis according to the iteration number were conducted. In addition, the physical distance between two BURs in the region of interest of each BUR was measured. RESULTS: The PDD of the proton beam from the water phantom including the BURs shows more efficient than that of conventional proton therapy on tumour region. A 719keV prompt gamma ray peak was clearly observed in the prompt gamma ray energy spectrum. The prompt gamma ray image was reconstructed successfully using 64 projections. Different image profiles including two BURs were acquired from the reconstructed image according to the iteration number. CONCLUSION: We confirmed successful acquisition of a prompt gamma ray image during PBFT. In addition, the quantitative image analysis results showed relatively good performance for further study.


Assuntos
Boro/efeitos da radiação , Boro/uso terapêutico , Terapia com Prótons/métodos , Terapia com Prótons/estatística & dados numéricos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Fenômenos Biofísicos , Simulação por Computador , Estudos de Viabilidade , Raios gama , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Imagens de Fantasmas , Terapia com Prótons/instrumentação
3.
Phys Med ; 32(4): 562-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26970679

RESUMO

We confirmed the feasibility of using our proposed system to extract two different kinds of functional images from a positron emission tomography (PET) module by using an insertable collimator during boron neutron capture therapy (BNCT). Coincidence events from a tumor region that included boron particles were identified by a PET scanner before BNCT; subsequently, the prompt gamma ray events from the same tumor region were collected after exposure to an external neutron beam through an insertable collimator on the PET detector. Five tumor regions that contained boron particles and were located in the water phantom and in the BNCT system with the PET module were simulated with Monte Carlo simulation code. The acquired images were quantitatively analyzed. Based on the receiver operating characteristic (ROC) curves in the five boron regions, A, B, C, D, and E, the PET and single-photon images were 10.2%, 11.7%, 8.2% (center region), 12.6%, and 10.5%, respectively. We were able to acquire simultaneously PET and single prompt photon images for tumor regions monitoring by using an insertable collimator without any additional isotopes.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Raios gama , Humanos , Método de Monte Carlo
4.
Bioprocess Biosyst Eng ; 38(3): 449-55, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25255969

RESUMO

Microalgae hold great promise as a source of biofuels and biochemicals. The main obstacles to their industrial application are the high cultivation and downstream costs related to media and harvesting. In the work, we explored the multiple potentials of seawater to address key issues relating to the cultivation of Scenedesmus obliquus. Seawater can sufficiently replace some of the key elements in BG11 medium such as MgSO4, CaCl2, and NaCO3, and its use can significantly reduce the quantity of water required for the preparation of culture media. Among our results, the total chlorophyll content in cells grown in modified BG11 using 10 % (v/v) seawater was increased 1.47-fold without sacrificing biomass or lipid production. More than 70 % of the total algal biomass was auto-flocculated within one hour when cells were grown in seawater-supplemented media, which compares very favorably with a yield of only 3 % from cells grown in BG11.


Assuntos
Scenedesmus/crescimento & desenvolvimento , Água do Mar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA