Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Neuroradiol ; 33(4): 1075-1086, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37368089

RESUMO

PURPOSE: Information about the cost-effectiveness of a certain treatment is relevant for decision-making and healthcare providers. This study compares the cost-effectiveness of the novel Woven Endobridge (WEB) for intracranial aneurysm treatment with conventional coiling and stent-assisted coiling (SAC) from the perspective of the German Statutory Health Insurance. METHODS: A patient-level simulation was constructed to simulate 55-year-old patients with an unruptured middle cerebral artery aneurysm (size: 3-11 mm) considering WEB treatment, coiling or SAC in terms of morbidity, angiographic outcome, retreatment, procedural and rehabilitation costs and rupture rates. Incremental cost-effectiveness ratios (ICERs) were calculated as costs per quality-adjusted life years (QALYs) and costs per year with neurologic morbidity avoided. Uncertainty was explored with deterministic and probabilistic sensitivity analyses. The majority of data were obtained from prospective multi-center studies and meta-analyses of non-randomized studies. RESULTS: In the base case, lifetime QALYs were 13.24 for the WEB, 12.92 for SAC and 12.68 for coiling. Lifetime costs were 20,440 € for the WEB, 23,167 € for SAC, and 8200 € for coiling. Compared to coiling, the ICER for the WEB was 21,826 €/QALY, while SAC was absolutely dominated by WEB. Probabilistic sensitivity analysis revealed that at a willingness-to-pay of ≥ 30,000 €/QALY, WEB was the preferred treatment. Deterministic sampling showed that the discount rate, material costs and retreatment rates had the largest impact on the ICERs. CONCLUSION: The novel WEB showed at least comparable cost-effectiveness to SAC for treatment of broad-based unruptured aneurysms. Considering all three modalities, coiling had the least costs; however this modality is often not appropriate for the treatment of wide-necked aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Análise Custo-Benefício , Estudos Prospectivos , Resultado do Tratamento , Stents , Estudos Retrospectivos
2.
Neuroradiology ; 65(4): 765-773, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36460785

RESUMO

PURPOSE: Endovascular coil occlusion represents the standard treatment for basilar tip aneurysms. Recently, this role has been rivalled by intrasaccular flow disruptors across numerous centres. We retrospectively compared WEB embolization and coiling for the treatment of ruptured basilar tip aneurysms. METHODS: Patients treated with WEB or coiling at four neurovascular centres were reviewed. Procedure-related complications, clinical outcome, and angiographic results were retrospectively compared. RESULTS: The study included 23 patients treated with the WEB (aneurysm size: 6.6 ± 1.9 mm) and 56 by coiling (aneurysm size: 6.7 ± 2.5 mm). Stent-assistance was more often necessary with coiling than with WEB embolization (32% vs. 4%, p = 0.009). A modified Rankin scale score ≤ 2 at discharge had 21 (37.5%) patients in the coiling group and 12 (52.2%) in the WEB group (p = 0.235). Immediate complete and adequate occlusion rates were 52% for the WEB and 87% for coiling. At short-term follow-up, these rates were 87% for the WEB and 72% for coiling, respectively. There was no delayed aneurysm re-bleeding during follow-up. CONCLUSION: Both coiling and WEB seem to prevent rebleeding in ruptured BTA aneurysms. WEB embolization required less frequently stent-support than coiling, potentially advantageous for SAH patients to avoid anti-platelet therapy in the light of concomitant procedures like ventricular drainage.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Correção Endovascular de Aneurisma , Aneurisma Intracraniano , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/cirurgia , Aneurisma Roto/cirurgia , Correção Endovascular de Aneurisma/efeitos adversos , Correção Endovascular de Aneurisma/métodos , Estudos Retrospectivos , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/prevenção & controle
3.
Quant Imaging Med Surg ; 12(7): 3640-3654, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35782261

RESUMO

Background: In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS). Methods: In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison. Results: Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3) vs. 2.7±0.5, 3 (2-3), P=0.03]. Using REACT, readers detected more plaques overall (n=57.3 vs. 47.7, P<0.001) and plaques of hyperintense signal (n=12.3 vs. 5.7, P=0.02) with higher diagnostic confidence [2.8±0.5, 3 (3-3) vs. 2.6±0.7, 3 (2-3), P<0.001] than CE-MRA. After analyzing a total of 1,260 segments, the vessel quality of all segments combined [4.61±0.66 vs. 4.58±0.68, 5 (4-5) vs. 5 (4-5), P=0.0299] and artifacts [4.51±0.70 vs. 4.44±0.73, 5 (4-5) vs. 5 (4-5), P>0.05] were comparable between the sequences with REACT showing a lower image noise [4.43±0.67 vs. 4.25±0.71, 5 (4-5) vs. 4 (4-5), P<0.001]. Conclusions: Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.

4.
Eur Radiol ; 32(9): 6427-6434, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389049

RESUMO

OBJECTIVES: The aim of this study was to evaluate whether simple 2D measurements in axial slices of head and neck CT examinations correlate with generally established measurements of body composition in abdominal CT at the height of the third lumbar vertebra and thus allow for an estimation of muscle and fat masses. METHODS: One hundred twenty-two patients who underwent concurrent CT of the head and neck and the abdomen between July 2016 and July 2020 were retrospectively included. For a subset of 30 patients, additional bioelectrical impedance analysis (BIA) was available. Areas of paraspinal muscles at the height of the third (C3) and fifth cervical vertebrae (C5) as well as the total cross-sectional area at the height of C3 and at the submandibular level were correlated with the results of abdominal measurements and BIA. Furthermore, intra- and interreader variabilities of all measurements were assessed. RESULTS: Regarding adipose tissue, good correlations were found between the total cross-sectional area of the patient's body at the submandibular level and at the height of C3 between both abdominal measurements and BIA results (r = 0.8-0.92; all p < 0.001). Regarding muscle, the total paraspinal muscle area at the height of C3 and C5 showed strong correlations with abdominal measurements and moderate to strong correlations with BIA results (r = 0.44-0.80; all p < 0.001), with the muscle area on C5 yielding slightly higher correlations. CONCLUSIONS: Body composition information can be obtained with comparable reliability from head and neck CT using simple biplanar measurements as from abdominal CT. KEY POINTS: • The total paraspinal muscle area at the height of C3 and C5 correlates strongly with abdominal muscle mass. • The total cross-sectional area at the submandibular level and at the height of C3 shows good correlations with abdominal fat mass. • The described measurements facilitate a rapid, opportunistic assessment of relevant body composition parameters.


Assuntos
Composição Corporal , Tomografia Computadorizada por Raios X , Abdome , Composição Corporal/fisiologia , Impedância Elétrica , Humanos , Músculo Esquelético , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
5.
J Nucl Med ; 63(11): 1677-1682, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35422443

RESUMO

In light of increasing health-care costs, higher medical expenses should be justified socioeconomically. Therefore, we calculated the effectiveness and cost effectiveness of PET using the radiolabeled amino acid O-(2-18F-fluoroethyl)-l-tyrosine (18F-FET) compared with conventional MRI for early identification of responders to adjuvant temozolomide chemotherapy. A recently published study in isocitrate dehydrogenase wild-type glioma patients suggested that 18F-FET PET parameter changes predicted a significantly longer survival already after 2 cycles whereas MRI changes were not significant. Methods: To determine the effectiveness and cost effectiveness of serial 18F-FET PET imaging, we analyzed published clinical data and calculated the associated costs from the perspective of the German Statutory Health Insurance system. Based on a decision-tree model, the effectiveness of 18F-FET PET and MRI was calculated-that is, the probability to correctly identify a responder as defined by an overall survival of at least 15 mo. To determine the cost effectiveness, the incremental cost effectiveness ratio (ICER) was calculated-that is, the cost for each additionally identified responder by 18F-FET PET who would have remained undetected by MRI. The robustness of the results was tested by deterministic and probabilistic Monte Carlo sensitivity analyses. Results: Compared with MRI, 18F-FET PET increased the rate of correctly identified responders to chemotherapy by 26%; thus, 4 patients needed to be examined by 18F-FET PET to identify 1 additional responder. Considering the respective costs for serial 18F-FET PET and MRI, the ICER resulted in €4,396.83 for each additional correctly identified responder by 18F-FET PET. Sensitivity analyses confirmed the robustness of the results. Conclusion: In contrast to conventional MRI, the model suggests that 18F-FET PET is cost-effective in terms of ICER values. Considering the high cost of temozolomide, the integration of 18F-FET PET has the potential to avoid premature chemotherapy discontinuation at reasonable cost.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Temozolomida/uso terapêutico , Análise Custo-Benefício , Neoplasias Encefálicas/metabolismo , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Tirosina
6.
J Magn Reson Imaging ; 49(7): e164-e175, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30267462

RESUMO

BACKGROUND: Decreasing MRI scan time is a key factor to increase patient comfort and compliance as well as the productivity of MRI scanners. PURPOSE/HYPOTHESIS: Compressed sensing (CS) should significantly accelerate 3D scans. This study evaluated the clinical application and cost effectiveness of accelerated 3D T2 sequences of the lumbar spine. STUDY TYPE: Prospective, cross-sectional, observational. POPULATION: Twenty healthy volunteers and 10 patients. FIELD STRENGTH/SEQUENCE: A 3D T2 TSE sequence, identical 3D sequences with three different parallel imaging and CS accelerating factors, and 2D TSE sequences as a clinical reference were obtained on a 3T scanner. ASSESSMENT: Three readers evaluated the sequences for delineation of anatomical structures and image quality. A quantitative analysis consisting of root mean square error, structural similarity index, signal-to-noise ratio, and contrast-to-noise ratio were performed. The scan times were used to calculate cost differences for each sequence. STATISTICAL TESTS: An analysis of variance with repeated measurements and the Friedman test were used to test for potential differences between the sequences. Post-hoc analysis was made with the chi-squared and Tukey-Kramer test. RESULTS: CS with factor 4.5 results in unchanged image quality compared to the T2 TSE for volunteers and patients (overall image impression: 4.75 vs. 4.20 [P = 0.73] and 4.90 vs. 4.47 [P = 0.44]). The CS 4.5 scan is 167 seconds (-39%) faster than the 3D and 216.5 seconds (-45%) faster than the 2D sequences. No significant differences was found for the diagnostic certainty in the volunteers and patients between 2D TSE and 3D CS 4.5 (P = 0.89 and P = 0.43). A reduction of scan time to 148 seconds (CS 8) was still rated acceptable for most diagnosis. DATA CONCLUSION: CS accelerates the 3D T2 without compromising image quality. The 3D sequences offer comparable diagnostic quality to the clinical 2D standard with less scan time (-45%), potentially increasing the productivity of MRI scanners. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019;49:e164-e175.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Artefatos , Análise Custo-Benefício , Estudos Transversais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Prospectivos , Razão Sinal-Ruído , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA