Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Diagnostics (Basel) ; 12(10)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36292052

RESUMO

Background: Computed tomography (CT) of the aorta and cardiac vessels, which is performed in patients with severe aortic valve stenosis (AS) before transcatheter aortic valve replacement (TAVR), offers the possibility of non-invasive detection of pulmonary hypertension (PH), for example, by determining the diameter of the main pulmonary artery (PA), the right pulmonary artery (RPA) or the left pulmonary artery (LPA). An improvement of the significance of these radiological parameters is often achieved by indexing to the body surface area (BSA). The aim of this study was to compare different echocardiographic systolic pulmonary artery pressure (sPAP) values with radiological data in order to define potential clinical cut-off values for the presence or absence of PH. Methods: A total of 138 patients with severe AS undergoing TAVR underwent pre-interventional transthoracic echocardiography with determination of sPAP values and performance of CT angiography (CTA) of the aorta and femoral arteries. Radiologically, the PA, RPA, LPA, and ascending aorta (AA) diameters were obtained. Vascular diameters were not only indexed to BSA but also ratios were created with AA diameter (for example PA/AA-ratio). From these CT-derived vascular parameters, AUROC curves were obtained regarding the prediction of different sPAP values (sPAP 40−45−50 mmHg) and finally correlation analyses were calculated. Results: The best AUROC and correlation analyses were generally obtained at an sPAP ≥ 40 mmHg. When considering diameters alone, the PA diameter was superior to the RPA and LPA. Indexing to BSA generally increased the diagnostic quality of the parameters, and finally, in a synopsis of all results, PA/BSA had the best AUC 0.741 (95% CI 0.646−0. 836; p < 0.001; YI 0.39; sensitivity 0.87; specificity 0.52) and Spearman's correlation coefficient (r = 0.408; p < 0.001) at an sPAP of ≥40 mmHg. Conclusions: Features related to pulmonary hypertension are fast and easily measurable on pre-TAVR CT and offer great potential regarding non-invasive detection of pulmonary hypertension in patients with severe AS and can support the echocardiographic diagnosis. In this study, the diameter of the main pulmonary artery with the additionally determined ratios were superior to the values of the right and left pulmonary artery. Additional indexing to body surface area and thus further individualization of the parameters with respect to height and weight can further improve the diagnostic quality.

2.
Pacing Clin Electrophysiol ; 38(1): 28-34, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25154425

RESUMO

BACKGROUND: Device replacements bear many potential risks for patients. Electrocautery should be used cautiously because of heating of the cautery tip which may lead to insulation melting. The PEAK PlasmaBlade™ (Medtronic Inc., Minneapolis, MN, USA) uses a novel technology to cut tissue. The objective of this study was to evaluate if this instrument is less destructive and can decrease complications and shorten procedure times. METHODS AND RESULTS: Two groups were compared: in group 1, surgery was done with scissors and conventional electrocautery, whereas the PEAK PlasmaBlade™ was used in group 2. Procedure time and complication rates were retrospectively investigated. Group 1 comprised 509 patients, while group 2 consisted of 102 patients. Procedure time in group 2 was significantly shorter with 28.4 ± 8.9 minutes than in group 1 with 47.5 ± 24.5 minutes (P < 0.001). The hospital stay was also reduced (2.1 ± 2.2 days versus 3.1 ± 2.4 days, P < 0.001). One major complication occurred in only 2.4% (two patients) of group 2 and in 6.9% (35 patients) of group 1. There were no damaged leads in group 2 compared to 5.7% in group 1 (P = 0.008). Cost analyses showed that the use of The PEAK PlasmaBlade™ instead of conventional electrocautery resulted in cost savings of €120/patient. CONCLUSION: Device replacement is associated with a notable complication risk. Our investigation showed that a new device for generator replacement resulted in significantly reduced procedure time and length of hospital stay while completely avoiding lead damage, which translated into considerable cost savings in a real world setting.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo/economia , Remoção de Dispositivo/instrumentação , Eletrocirurgia/economia , Eletrocirurgia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Análise Custo-Benefício , Remoção de Dispositivo/efeitos adversos , Eletrocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Recursos em Saúde/estatística & dados numéricos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA