Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Pharm Pharm Sci ; 23: 437-450, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33156995

RESUMO

PURPOSE: The main aim of the current research was to develop and apply a dermatopharmacokinetic (DPK) approach for the bioequivalence assessment of metronidazole (MTZ) topical cream products, indicated in the treatment of rosacea. METHODS: A DPK methodology using tape stripping (TS) technique was developed by investigating the factors that may influence the TS results viz. tapes, dose durations, number of tapes to be used, pressure application, dose applied and gravimetric analysis of the tapes. An initial dose duration study was performed on 6 healthy participants to determine an appropriate application time duration using the Emax model. The SC thickness was normalised between participants using TEWL measurements. A pivotal study was conducted using both the arms of 10 healthy human participants to demonstrate the ability of the TS method for bioequivalence assessment by comparing the reference product to itself as a positive control and including products with higher and lower strengths of MTZ to serve as negative controls in order to confirm bioinequivalence. RESULTS: Whereas the reference was found to be bioequivalent when compared to itself, the creams containing 0.56% and 0.95% MTZ (negative controls) were not bioequivalent (bioinequivalent). Furthermore, another product containing 0.75% MTZ was also assessed and was found to be bioequivalent to the reference product. In addition, the use of both forearms of each participant offered an important advantage of significantly reducing the number of human subjects required to demonstrate BE with a high statistical power of > 80%. CONCLUSION: The data obtained provides compelling evidence that the developed TS method has the potential to be a cost-effective surrogate alternative for lengthy and expensive clinical trials. Consequently, its application can facilitate faster development of generic products which would, in turn, lower the economic burden of healthcare.


Assuntos
Fármacos Dermatológicos/administração & dosagem , Metronidazol/administração & dosagem , Modelos Biológicos , Administração Cutânea , Adulto , Fármacos Dermatológicos/farmacocinética , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Metronidazol/farmacocinética , Projetos Piloto , Absorção Cutânea , Creme para a Pele , Equivalência Terapêutica , Fatores de Tempo , Perda Insensível de Água , Adulto Jovem
2.
Pharm Res ; 37(2): 20, 2020 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-31897770

RESUMO

PURPOSE: The purpose of this study was (a) to suggest a novel dermatopharmacokinetic (DPK) approach from which pharmacokinetic parameters relevant to the bioequivalence (BE) assessment of a topical formulation can be deduced while circumventing the need for numerous measurements and assumptions, and (b) to investigate whether this approach enables the correct conclusion of BE and bioinequivalence (BIE). METHODS: Bioequivalent and bioinequivalent formulations of acyclovir were compared versus a reference product (Zovirax®). Tape Stripping was conducted at only one dose duration during the uptake phase to generate drug content in stratum corneum versus time profiles, each time point corresponding to one stripped layer. Nonlinear mixed effect modeling (ADAPT5®) (MLEM algorithm) was used to fit the DPK data and to estimate the rate (Kin) and extent (FS) of drug absorption/input into the skin. Results were evaluated using the average BE approach. RESULTS: Estimated exposure metrics were within the usual BE limits for the bioequivalent formulation (FS: 102.4 [90%CI: 97.5-107.7]; Kin: 94.2 [90%CI: 83.7-106.0]), but outside those limits for the bioinequivalent formulation (FS: 43.4 [90%CI: 27.9-67.6]; Kin: 54.5 [90%CI: 36.6-81.1]). CONCLUSIONS: The proposed novel DPK approach was shown to be successful, robust and applicable to assess BE and BIE correctly between topical formulations.


Assuntos
Pomadas/química , Administração Cutânea , Disponibilidade Biológica , Química Farmacêutica/métodos , Epiderme/efeitos dos fármacos , Feminino , Humanos , Masculino , Pomadas/farmacocinética , Pomadas/farmacologia , Pele/efeitos dos fármacos , Absorção Cutânea/fisiologia , Equivalência Terapêutica
3.
AAPS PharmSciTech ; 19(4): 1567-1573, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29484615

RESUMO

This study indicates the application of tape stripping (TS) for bioequivalence (BE) assessment of a topical cream product containing 5% acyclovir. A TS method, previously used successfully to assess BE of topical clobetasol propionate and clotrimazole formulations, was used to assess BE of an acyclovir cream (5%) formulation as well as a diluted acyclovir formulation (1.5%) applied to the skin of healthy humans. An appropriate application time was established by conducting a dose duration study using the innovator product, Zovirax® cream. Transepidermal water loss was measured and used to normalize thicknesses between subjects. The area under the curve (AUC) from a plot of amount of acyclovir/strip vs cumulative fraction of stratum corneum (SC) removed was calculated for each application site. BE was assessed using Fieller's theorem in accordance with FDA's guidance for assessment of BE of topical corticosteroids. Adco-acyclovir cream (5%) was found to be BE to Zovirax® cream, where the mean test/reference (T/R) ratio of the AUC's was 0.96 and the bioequivalence interval using a 90% confidence interval was 0.91-1.01 with a statistical power > 95%, whereas the diluted test product fell outside the BE acceptance criteria with T/R ratio of AUC of 0.23 and a 90% CI of 0.20-0.26. This study indicates that the data resulting from the application of this TS procedure has reinforced the potential for its use to assess BE of topical drug products intended for local action, thereby obviating the necessity to undertake clinical trials in patients.


Assuntos
Aciclovir/administração & dosagem , Aciclovir/farmacocinética , Absorção Cutânea/efeitos dos fármacos , Creme para a Pele/administração & dosagem , Creme para a Pele/farmacocinética , Administração Tópica , Adulto , Antivirais/administração & dosagem , Antivirais/metabolismo , Fármacos Dermatológicos/administração & dosagem , Fármacos Dermatológicos/metabolismo , Epiderme/efeitos dos fármacos , Epiderme/metabolismo , Feminino , Humanos , Masculino , Absorção Cutânea/fisiologia , Equivalência Terapêutica
4.
AAPS PharmSciTech ; 15(5): 1076-86, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24848760

RESUMO

Biowaivers are recommended for immediate-release solid oral dosage forms using dissolution testing as a surrogate for in vivo bioequivalence studies. Several guidance are currently available (the World Health Organization (WHO), the US FDA, and the EMEA) where the conditions are described. In this study, definitions, criteria, and methodologies according to the WHO have been applied. The dissolution performances of immediate-release metronidazole, zidovudine, and amoxicillin products purchased in South African and Indian markets were compared to the relevant comparator pharmaceutical product (CPP)/reference product. The dissolution performances were studied using US Pharmacopeia (USP) apparatus 2 (paddle) set at 75 rpm in each of three dissolution media (pH1.2, 4.5, and 6.8). Concentrations of metronidazole, zidovudine, and amoxicillin in each dissolution media were determined by HPLC. Of the 11 metronidazole products tested, only 8 could be considered as very rapidly dissolving products as defined by the WHO, whereas 2 of those products could be considered as rapidly dissolving products but did not comply with the f 2 acceptance criteria in pH 6.8. All 11 zidovudine products were very rapidly dissolving, whereas in the case of the 14 amoxicillin products tested, none of those products met any of the WHO criteria. This study indicates that not all generic products containing the same biopharmaceutics classification system (BCS) I drug and in similar strength and dosage form are necessarily in vitro equivalent. Hence, there is a need for ongoing market surveillance to determine whether marketed generic products containing BCS I drugs meet the release requirements to confirm their in vitro bioequivalence to the respective reference product.


Assuntos
Amoxicilina/química , Antibacterianos/química , Fármacos Anti-HIV/química , Antitricômonas/química , Metronidazol/química , Zidovudina/química , Química Farmacêutica , Formas de Dosagem , Liberação Controlada de Fármacos , Medicamentos Genéricos , Índia , Solubilidade , África do Sul
5.
Pharm Res ; 31(4): 837-46, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24395404

RESUMO

This paper summarises the proceedings of a recent workshop which brought together pharmaceutical scientists and dermatologists from academia, industry and regulatory agencies to discuss current regulatory issues and industry practices for establishing therapeutic bioequivalence (BE) of dermatologic topical products. The methods currently available for assessment of BE were reviewed as well as alternatives and the advantages and disadvantages of each method were considered. Guidance on quality and performance of topical products was reviewed and a framework to categorise existing and alternative methods for evaluation of BE was discussed. The outcome of the workshop emphasized both a need for greater attention to quality, possibly, via a Quality-By-Design (QBD) approach and a need to develop a "whole toolkit" approach towards the problem of determination of rate and extent in the assessment of topical bioavailability. The discussion on the BE and clinical equivalence of topical products revealed considerable concerns about the variability present in the current methodologies utilized by the industry and regulatory agencies. It was proposed that academicians, researchers, the pharmaceutical industry and regulators work together to evaluate and validate alternative methods that are based on both the underlying science and are adapted to the drug product itself instead of single "universal" method.


Assuntos
Fármacos Dermatológicos/administração & dosagem , Fármacos Dermatológicos/farmacocinética , Educação/tendências , Tecnologia Farmacêutica/tendências , Administração Tópica , Animais , Disponibilidade Biológica , Humanos , Absorção Cutânea/efeitos dos fármacos , Absorção Cutânea/fisiologia , Equivalência Terapêutica
6.
J Pharm Pharm Sci ; 13(1): 11-20, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20456826

RESUMO

PURPOSE: A draft guidance on tape stripping for assessing the bioavailability/bioequivalence of topical formulations was issued by the United States Food and Drug Administration in 1998 but has since been withdrawn. This was due to problems associated with the method and also inconsistencies and variability in the resulting data. The purpose of this study was to re-visit the tape stripping technique, incorporate refinements to reduce variability and validate the method using bioequivalence data obtained from the assessment of a topical corticosteroid cream containing 0.05% clobetasol propionate using the human skin-blanching assay. METHODS: A pilot tape stripping study was conducted to establish the variability of the formulations.The bioequivalence of two different commercially available clobetasol propionate cream formulations and a clobetasol propionate ointment formulation were subsequently investigated using the tape stripping method. RESULTS: The data from the pilot tape stripping study correlated well with data from the human skin-blanching assay. A subsequent pivotal tape stripping study confirmed bioequivalence between the two cream formulations whereas bio-inequivalence was demonstrated between the cream and ointment formulations. CONCLUSIONS: These studies show that the results from tape stripping concur with data from the human skin blanching assay and demonstrate the potential of a well-controlled tape stripping study as an option for the assessment of bioequivalence of topical corticosteroid formulations.


Assuntos
Clobetasol/farmacocinética , Glucocorticoides/farmacocinética , Pele/metabolismo , Administração Cutânea , Adulto , Disponibilidade Biológica , Clobetasol/administração & dosagem , Feminino , Glucocorticoides/administração & dosagem , Humanos , Masculino , Projetos Piloto , Absorção Cutânea , Equivalência Terapêutica , Estados Unidos , United States Food and Drug Administration , Adulto Jovem
7.
J Pharm Biomed Anal ; 49(5): 1308-12, 2009 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-19375262

RESUMO

A pharmacokinetic interaction study between efavirenz (EFV), a non-nucleoside reverse transcriptase inhibitor used in the treatment of HIV-1 infection, and an African traditional medicine, African potato in human subjects was undertaken. This necessitated the development and validation of a quantitative method for the analysis of EFV in plasma. A simple mobile phase consisting of 0.1M formic acid, acetonitrile and methanol (43:52:5) was pumped at a low flow rate of 0.3 ml/min through a reverse phase Phenomenex Luna C(18) (2) (5 microm, 150 mm x 2.0mm i.d.) column maintained at 40 degrees C. Diclofenac sodium was used as an internal standard (IS) and EFV and IS were monitored at 247 nm and 275 nm, respectively. A simple and rapid sample preparation involved the addition of mobile phase to 100 microl of plasma to precipitate plasma proteins followed by direct injection of 10 microl of supernatant onto the column. The procedures were validated according to international standards with good reproducibility and linear response (r=0.9990). The intra- and inter-day accuracies were between 12.3 and 17.7% at the LLOQ and between -5.8 and 9.1% for the QC samples. The intra- and inter-day precision of EFV determinations were 5.1 or less and 7.2% RSD or less, respectively across the entire QC concentration range. Mean recovery based on high, medium and low quality control standards ranged between 92.7 and 94.1% with %RSD values better than 3%. Plasma samples were evaluated for short-term (ambient temperature for 6h) and long-term (-10+/-2 degrees C for 60 days) storage conditions and were found to be stable. The method described is cost-effective and has the necessary accuracy and precision for the rapid quantitative determination of EFV in human plasma.


Assuntos
Benzoxazinas/sangue , Inibidores da Transcriptase Reversa/sangue , Alcinos , Calibragem , Cromatografia Líquida de Alta Pressão/economia , Cromatografia Líquida de Alta Pressão/métodos , Ciclopropanos , Estabilidade de Medicamentos , Congelamento , Humanos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta/métodos , Temperatura , Fatores de Tempo
8.
J Pharm Pharm Sci ; 11(1): 160-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18445371

RESUMO

PURPOSE: The assessment of the degree of skin blanching following the application of a formulation containing a topical corticosteroid has been established as a surrogate method for the determination of bioequivalence. In this study, both visual and chromametric assessments have been carried out on two topical creams containing clobetasol propionate (0.05%) and the results from both methods are compared. METHODS: Human subjects (volunteers) were screened using a cream containing 0.05%clobetasol propionate, in order to identify appropriate subjects for inclusion in the study. The study was implemented according to the FDA guidance using both visual and chromameter assessment techniques. Blanching responses were assessed visually by three trained, independent observers and instrumentally using a Chromameter. An ED50 of 36 min was used as the dose duration based upon data previously obtained from a pilot study using the same topical corticosteroid reference product. A visual rating scale of 0-4 and the a-scale readings from the chromameter were used. RESULTS: The visual and chromameter blanching profiles showed similar blanching responses with good correspondence. The 90% confidence intervals for the data from both methods were calculated using Locke's method. When only the data obtained from 23 subjects who were identified as"detectors" (as per FDA guidance) were used, the products fell within the bioequivalence acceptance range of 80-125% using the visual assessment method (99.3-111.6%) whereas the data using a chromameter (86.5-129.3%) were just outside the acceptance limits. However, when all subjects (n=34) were included in the calculations, both the visual (97.9-109.2) and chromameter (90.2-120.7) data fell within the bioequivalence acceptance range. CONCLUSIONS: Whereas visual data indicated bioequivalence using either data from "detectors" or data from all subjects, the chromameter data from "detectors" only indicated bioinequivalence but inclusion of all subject data fell within the acceptance range to be declared bioequivalent.


Assuntos
Clobetasol/administração & dosagem , Clobetasol/farmacocinética , Pele/metabolismo , Visão Ocular , Administração Cutânea , Adulto , Cromatografia , Feminino , Humanos , Masculino , Testes do Emplastro/métodos , Pele/efeitos dos fármacos , Absorção Cutânea/efeitos dos fármacos , Absorção Cutânea/fisiologia , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA