RESUMO
A risk assessment study of dioxins in sanitary napkins produced in Japan was performed. The daily estimated exposure volume to dioxins was compared with the tolerable daily intake (TDI). The concentrations of dioxins such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) in seven sanitary napkins were measured using gas chromatography and mass spectroscopy analytical methods. Among the seven napkins, a range of 0.0044-0.076pg TEQ/g dioxins was measured. Daily estimated exposure volume from sanitary napkins was calculated as follows: (dioxin volumes in a sanitary napkin (0.0044-0.076pg TEQ/g)×pulp weight in a sanitary napkin (11.2g)×used napkin numbers/d (7.5)×the number of days/month that women use sanitary napkins (7)×skin absorption rate (0.03)×used years (40))/(average body weight of women (50kg)×the number of days in the month (30)×life years (86)). Daily exposure volumes were estimated to be 0.000024-0.00042pg TEQ/kg/d. For hazard assessment, we used 0.7pg TEQ/kg/d which was the lowest level of TDI among TDI values reported by international agencies. When the daily exposure volume was compared with the TDI, the former was approximately 1666-29,166 times less than the latter. This fact indicated that the risk of exposure to dioxins from sanitary napkins produced in Japan was negligible.
Assuntos
Benzofuranos/análise , Produtos de Higiene Menstrual/normas , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análogos & derivados , Dibenzofuranos Policlorados , Feminino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Japão , Nível de Efeito Adverso não Observado , Dibenzodioxinas Policloradas/análise , Medição de Risco/métodosRESUMO
BACKGROUND: Osteochondral autografts with use of the olecranon tip, lateral radial head, or proximal radial head have been employed for coronoid process reconstruction. However, it is unclear which autograft is most suitable for coronoid articular configuration. We assessed 3-dimensional articular facet suitability of 3 osteochondral autografts for coronoid process reconstruction. METHODS: We performed 3-dimensional computed tomography of 20 elbows to compare the articular facet configuration between the coronoid process and the ipsilateral olecranon tip, lateral radial head, and proximal radial head. We measured the area of the proximity region (≤2.0 mm) between the articular facets of the coronoid process and 3 osteochondral autografts, the covering rate defined as the percentage area of the coronoid articular facet occupied by the proximity region, the location of the proximity region center, and the percentage of the removed ulnohumeral articular facet. RESULTS: The covering rate was significantly higher with an olecranon graft than with radial head grafts. The regional center of a proximal radial head graft was significantly medial compared with that of olecranon and lateral radial head grafts. The olecranon graft used an average of 13.8% of the ulnohumeral articular facet. CONCLUSIONS: An olecranon graft was most suitable for defects of the coronoid process involving the tip, and a proximal radial head graft was most suitable for defects of the coronoid process involving the anteromedial rim. The use of an olecranon graft for reconstruction of 50% of the height of the coronoid process does not cause concern for gross elbow instability.