RESUMO
Particulate matter is a common health hazard, and under certain conditions, an ecological threat. While many studies were conducted in regard to air pollution and potential effects, this paper serves as a pilot scale investigation into the spatial and temporal variability of particulate matter (PM) pollution in arid urban environments in general, and Beer-Sheva, Israel as a case study. We explore the use of commercially off the shelf (COTS) sensors, which provide an economical solution for spatio-temporal measurements. We started with a comparison process against an A-grade meteorological station, where it was shown that under specific climatic conditions, a number of COTS sensors were able to produce robust agreement (mean R2=0.93, average SD=17.5). The second stage examined the COTS sensors that were proven accurate in a mobile measurement campaign. Finally, data collected was compared to a validated satellite prediction model. We present how these tests and COTS sensor-kits could then be used to further explain the continuity and dispersion of particulate matter in similar areas.
Assuntos
Poluentes Atmosféricos , Poluição do Ar , Monitoramento Ambiental , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Exposição AmbientalRESUMO
Millions of people live in areas that are subject to frequent dust events; however gaps remain in our knowledge about the association between dust, air quality and corresponding particulate matter (PM) exposure levels inside buildings. This case study demonstrates how the PM2.5 and PM10 levels in an urban environment respond to strong natural dust episodes. Real-time measurements were recorded simultaneously in indoor and outdoor environments in households in the city of Beer-Sheva, Israel during several strong dust events. A typical strong event was used for a detailed analysis of PM10 and PM2.5. Outdoor daily concentrations were above 1000 µg m-3 for PM10, the maximum hourly value of which was 1320 µg m-3. The indoor PM10 peaked at about 700 µg m-3 and fluctuated in parallel with the outdoor level but with a time lag of about 15 min. Indoor air tended to remain for several hours after the dust event had subsided. Analyses of multiple events revealed that the dependence of indoor PM2.5 and PM10 on natural dust varies but is not directly linked to the level of atmospheric dust concentration. From a health perspective, the exposure risk posed by extreme indoor PM2.5 and PM10 levels generated by natural dust episodes should be considered.