Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(7): e012854, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38758741

RESUMO

BACKGROUND: Unlike conventional microsecond pulsed electrical fields that primarily target the cell membranes, nanosecond pulses are thought to primarily electroporate intracellular organelles. We conducted a comprehensive preclinical assessment of catheter-based endocardial nanosecond pulsed field ablation in swine. METHODS: A novel endocardial nanosecond pulsed field ablation system was evaluated in a total of 25 swine. Using either a low-dose (5-second duration) or high-dose (15-second duration) strategy, thoracic veins and discrete atrial and ventricular sites were ablated. Predetermined survival periods were <1 (n=1), ≈2 (n=7), ≈7 (n=6), 14 (n=2), or ≈28 (n=9) days, and venous isolation was assessed before euthanasia. Safety assessments included evaluation of esophageal effects, phrenic nerve function, and changes in venous caliber. All tissues were subject to careful gross pathological and histopathologic examination. RESULTS: All (100%) veins (13 low-dose, 34 high-dose) were acutely isolated, and all reassessed veins (6 low-dose, 15 high-dose) were durably isolated. All examined vein lesions (10 low-dose, 22 high-dose) were transmural. Vein diameters (n=15) were not significantly changed. Of the animals assessed for phrenic palsy (n=9), 3 (33%) demonstrated only transient palsy. There were no differences between dosing strategies. Thirteen mitral isthmus lesions were analyzed, and all 13 (100%) were transmural (depth, 6.4±0.4 mm). Ventricular lesions were 14.7±4.5 mm wide and 7.1±1.3 mm deep, with high-dose lesions deeper than low-dose (7.9±1.2 versus 6.2±0.8 mm; P=0.007). The esophagus revealed nontransmural adventitial surface lesions in 5 of 5 (100%) animals euthanized early (2 days) post-ablation. In the 10 animals euthanized later (14-28 days), all animals demonstrated significant esophageal healing-8 with complete resolution, and 2 with only trace fibrosis. CONCLUSIONS: A novel, endocardial nanosecond pulsed field ablation system provides acute and durable venous isolation and linear lesions. Transient phrenic injury and nontransmural esophageal lesions can occur with worst-case assessments suggesting limits to pulsed field ablation tissue selectivity and the need for dedicated assessments during clinical studies.


Assuntos
Estudos de Viabilidade , Nervo Frênico , Animais , Suínos , Fatores de Tempo , Miocárdio/patologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias/fisiopatologia , Modelos Animais , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/patologia , Esôfago , Átrios do Coração/fisiopatologia , Átrios do Coração/patologia
2.
Europace ; 25(4): 1369-1378, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794699

RESUMO

AIMS: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine. METHODS AND RESULTS: The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury. CONCLUSION: This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Suínos , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Veias Pulmonares/cirurgia , Veias Pulmonares/patologia , Veia Cava Superior/cirurgia , Estudos de Viabilidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do Tratamento
3.
JACC Clin Electrophysiol ; 9(5): 652-666, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36842871

RESUMO

BACKGROUND: A multielectrode spherical array catheter capable of single-shot mapping and ablation has been introduced. OBJECTIVES: This study sought to compare the efficacy and safety of circumferential, linear, and focal ablation using either microsecond pulsed field (PF) and radiofrequency (RF) ablation in preclinical model. METHODS: Under general anesthesia, a 122 gold-plated multielectrode array was introduced into the left atrium. Twenty-nine canines underwent isolation of two pulmonary veins (PVs), with linear and focal left atrial ablation with both RF (n = 12) and PF (n = 17). PF was also delivered within the superior vena cava and atop the esophagus in three swine. Animals were sacrificed acutely (immediately for RF [6 of 12] and 3 days for PF [6 of 17]) and the remaining (n = 17) at 14 to 30 days. Detailed necropsy and histopathology were performed. RESULTS: All PVs were acutely (58 of 58) and durably (34 of 34) isolated and exhibited wide confluent lesions. Lesions were transmural for 97% to 100% of sections with depths of 2.5 to 3.4 mm and 2.5 to 3.5 mm in the acute and chronic cohorts, respectively. Linear and focal lesions displayed transmurality rates of 85% to 100% with depths of 3.5 millimeters to 4.2 millimeters in the acute cohort. In the chronic cohorts, linear lesions created with RF, PF+RF, and PF had no significant differences in depth (3.5 ± 1.8 mm, 4.0 ± 1.4 mm, and 3.9 ± 0.9 mm) or transmurality (83.3%, 100%, and 80%). Current of injury was seen on local unipolar electrogram immediately after PF and RF, and this occurred to a wider extent with PF. PF but not RF elicited bradycardia from ganglionated plexi stimulation. There were no instances of phrenic palsy, venous stenosis, esophageal damage, or thromboembolism. CONCLUSIONS: Circumferential, linear, and focal mapping and ablation can be achieved with this novel catheter using both PF and RF, with excellent efficacy and safety.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Cães , Veia Cava Superior/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Catéteres
4.
Circ Arrhythm Electrophysiol ; 13(6): e008716, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32370542

RESUMO

BACKGROUND: A novel ablation and mapping system can toggle between delivering biphasic pulsed field (PF) and radiofrequency energy from a 9-mm lattice-tip catheter. We assessed the preclinical feasibility and safety of (1) focal PF-based thoracic vein isolation and linear ablation, (2) combined PF and radiofrequency focal ablation, and (3) PF delivered directly atop the esophagus. METHODS: Two cohorts of 6 swine were treated with pulsed fields at low dose (PFLD) and high dose (PFHD) and followed for 4 and 2 weeks, respectively, to isolate 25 thoracic veins and create 5 right atrial (PFLD), 6 mitral (PFHD), and 6 roof lines (radiofrequency+PFHD). Baseline and follow-up voltage mapping, venous potentials, ostial diameters, and phrenic nerve viability were assessed. PFHD and radiofrequency lesions were delivered in 4 and 1 swine from the inferior vena cava onto a forcefully deviated esophagus. All tissues were submitted for histopathology. RESULTS: Hundred percent of thoracic veins (25 of 25) were successfully isolated with 12.4±3.6 applications/vein with mean PF times of <90 seconds/vein. Durable isolation improved from 61.5% PFLD to 100% with PFHD (P=0.04), and all linear lesions were successfully completed without incurring venous stenoses or phrenic injury. PFHD sections had higher transmurality rates than PFLD (98.3% versus 88.1%; P=0.03) despite greater mean thickness (2.5 versus 1.3 mm; P<0.001). PF lesions demonstrated homogenous fibrosis without epicardial fat, nerve, or vessel involvement. In comparison, radiofrequency+PFHD sections revealed similar transmurality but expectedly more necrosis, inflammation, and epicardial fat, nerve, and vessel involvement. Significant ablation-related esophageal necrosis, inflammation, and fibrosis were seen in all radiofrequency sections, as compared with no PF sections. CONCLUSIONS: The lattice-tip catheter can deliver focal PF to durably isolate veins and create linear lesions with excellent transmurality and without complications. The PF lesions did not damage the phrenic nerve, vessels, and the esophagus.


Assuntos
Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Irrigação Terapêutica , Potenciais de Ação , Animais , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Modelos Animais , Complicações Pós-Operatórias/patologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Sus scrofa , Irrigação Terapêutica/efeitos adversos , Irrigação Terapêutica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA