Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Radiol ; 27(2): 697-704, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27236816

RESUMO

OBJECTIVES: To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. METHODS: Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. RESULTS: Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. CONCLUSIONS: 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. KEY POINTS: • Quantification of left-to-right shunting can be performed reliably and accurately by CT. • The sizes of defects and rims can be measured accurately using 256-slice CT. • 256-slice CT permits pretreatment evaluation of ASD non-invasively and comprehensively.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Comunicação Interatrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Circulação Coronária , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Comunicação Interatrial/cirurgia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Eur Radiol ; 26(10): 3617-25, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26795615

RESUMO

OBJECTIVES: To investigate the utility of eccentricity index (EI) using cardiac cine MRI for the assessment of right ventricular (RV) hemodynamics in congenital heart disease (CHD). METHODS: Fifty-five patients with CHD (32 women; mean age, 40.7 ± 20.9 years) underwent both cardiac MRI and right heart catheterization. EI was defined as the ratio of the distance between the anterior-posterior wall and the septal-lateral wall measured in the short-axis of mid-ventricular cine MRI. Correlations between EIs and RV hemodynamic parameters were analyzed. EIs were compared between patients with and without late gadolinium enhancement (LGE). RESULTS: A strong correlation between mean pulmonary artery pressure (PAP) and systolic EI (r = 0.81, p < 0.0001) and a moderate negative correlation between diastolic EI and RV ejection fraction (EF) (r = -0.62, p < 0.0001) were observed. Receiver operating characteristic analysis revealed optimal EI thresholds for detecting patients with mean PAP ≥40 mmHg with C-statistics of 0.90 and patients with RVEF <40 % with C-statistics of 0.78. Systolic EIs were significantly greater for patients with LGE (1.45 ± 0.05) than for those without LGE (1.15 ± 0.07; p < 0.001). CONCLUSIONS: EI offers a simple, comprehensive index that can predict pulmonary hypertension and RV dysfunction in CHD. KEY POINTS: • EI offers a simple and comprehensive index of RV hemodynamics. • EI could predict pulmonary hypertension and RV dysfunction. • Left ventricular deformation expressed as high EI is related to myocardial fibrosis.


Assuntos
Cardiopatias Congênitas/fisiopatologia , Miocárdio/patologia , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Cateterismo Cardíaco/métodos , Feminino , Fibrose , Cardiopatias Congênitas/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Hipertensão Pulmonar/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Curva ROC , Sístole/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Adulto Jovem
3.
Eur Radiol ; 24(12): 3289-99, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25113649

RESUMO

OBJECTIVES: To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). METHODS: Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. RESULTS: CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0%) and PRF (-9.1 ± 2.0%) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. CONCLUSIONS: 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. KEY POINTS: 256-slice CT assessment of RV function is highly reproducible in repaired TOF. Pulmonary regurgitation can be evaluated by biventricular systolic volume difference. CT overestimates RV volume and underestimates pulmonary regurgitation, compared with MRI.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores/métodos , Insuficiência da Valva Pulmonar/diagnóstico , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Volume Sistólico , Sístole , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia
4.
Eur J Radiol ; 81(8): 1695-701, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21620599

RESUMO

OBJECTIVE: We developed a new volume rendering technique, the CT gastrography wall carving image (WC) technique, which provides a clear visualization of localized enhanced tumors in the gastric wall. We evaluated the diagnostic performance of the WC as an adjunct to conventional images in detecting early gastric cancer (EGC). MATERIALS AND METHODS: Thirty-nine patients with 43 EGCs underwent contrast-enhanced MDCT gastrography for preoperative examination. Two observers independently reviewed the images under three different conditions: term 1, Axial CT; term 2, Axial CT, MPR and VE; and term 3, Axial CT, MPR, VE and WC for the detection of EGC. The accuracy of each condition as reviewed by each of the two observers was evaluated by receiver operating characteristic analysis. Interobserver agreement was calculated using weighted-κ statistics. RESULTS: The best diagnostic performance and interobserver agreement were obtained in term 3. The AUCs of the two observers for terms 1, 2, and 3 were 0.63, 0.73, and 0.84, and 0.57, 0.73, and 0.76, respectively. The interobserver agreement improved from fair at term 1 to substantial at term 3. CONCLUSIONS: The addition of WC to conventional MDCT display improved the diagnostic accuracy and interobserver reproducibility for the detection of ECG. WC represents a suitable alternative for the visualization of localized enhanced tumors in the gastric wall.


Assuntos
Detecção Precoce de Câncer/métodos , Imageamento Tridimensional/métodos , Iopamidol , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias Gástricas/diagnóstico por imagem , Estômago/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA