RESUMO
BACKGROUND: The postoperative varus/valgus stability assessment in stress X-rays has been established as an evaluation index. However, it is performed by the two-dimensional (2D) method rather than the three-dimensional (3D) method. OBJECTIVE: This study aimed to identify the precision and reproducibility of measuring varus/valgus stress X-rays three-dimensionally and to examine varus/valgus stability under anesthesia in imageless robotic assisted total knee arthroplasty (rTKA). METHODS: This prospective study analyzed 52 consecutive rTKAs (five males, 67 ± 5.3 years; 47 females, 74 ± 5.9 years). Postoperative varus/valgus stress X-rays in knee extension under anesthesia at manual maximum stress were three-dimensionally assessed by 2D-3D image matching technique using the 3D bone and component models. Varus/valgus angle between components (VV angle) in no stress, valgus stress, varus stress, medial joint opening (MJO), and lateral joint opening (LJO) were evaluated, clarifying this method's precision and reproducibility and valgus/varus stability. RESULTS: All parameters' precision and reproducibility had <1° mean differences and high intra- and inter-class correlation coefficients. Bland-Altman plots showed no fixed and proportional bias. Non-stress VV angle, valgus VV angle, varus VV angle, MJO, and LJO were 3.6 ± 1.2°, 1.0 ± 1.4°, 7.1 ± 1.9°, 1.5 ± 1.0 mm, and 2.8 ± 2.7 mm, respectively. CONCLUSION: This prospective study demonstrated that (1) the three-dimensional measurement method provided sufficient precision and reproducibility, and (2) the rTKAs could achieve good postoperative varus/valgus stability with a small standard deviation.
Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Masculino , Feminino , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Raios X , Reprodutibilidade dos Testes , Estudos Prospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgiaRESUMO
Prominent osteoconductive activity and the biodegradable nature of commercially available beta-tricalcium phosphate (beta-TCP, OSferion) have been documented in animal experiments. We analyzed four cases of involving grafted OSferion in human bone with respect to histological features by routine hematoxylin and eosin staining, silver impregnation, immunohistochemistry and in situ hybridization. OSferion affords early bioresorption by osteoclasts, vascular invasion of macropores and osteoblastic cell attachment on the surface on the ceramic surface 14 days after grafting. Prominent bone formation and direct bone connection between preexisting bone and OSferion were evident 28 days after grafting. Nearly the entire TCP surface was covered by lamellar bone; additionally, active osteoblastic lining and attachment of the osteoclast-like giant cells were not observed 72 weeks after grafting. Silver impregnation revealed the presence of collagen fibrils within probable micropores of OSferion.