Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Biomed Opt Express ; 13(9): 5050-5066, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36187256

RESUMO

Hepatocellular carcinoma is one of the most lethal cancers worldwide, causing almost 700,000 deaths annually. It mainly arises from cirrhosis, which, in turn, results from chronic injury to liver cells and corresponding fibrotic changes. Although it is known that chronic liver injury increases the elasticity of liver tissue, the role of increased elasticity of the microenvironment as a possible hepatocarcinogen is yet to be investigated. One reason for this is the paucity of imaging techniques capable of mapping the micro-scale elasticity variation in liver and correlating that with cancerous mechanisms on the cellular scale. The clinical techniques of ultrasound elastography and magnetic resonance elastography typically do not provide micro-scale resolution, while atomic force microscopy can only assess the elasticity of a limited number of cells. We propose quantitative micro-elastography (QME) for mapping the micro-scale elasticity of liver tissue into images known as micro-elastograms, and therefore, as a technique capable of correlating the micro-environment elasticity of tissue with cellular scale cancerous mechanisms in liver. We performed QME on 13 freshly excised healthy and diseased mouse livers and present micro-elastograms, together with co-registered histology, in four representative cases. Our results indicate a significant increase in the mean (×6.3) and standard deviation (×6.0) of elasticity caused by chronic liver injury and demonstrate that the onset and progression of pathological features such as fibrosis, hepatocyte damage, and immune cell infiltration correlate with localized variations in micro-elastograms.

2.
Biomed Opt Express ; 12(3): 1666-1682, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796380

RESUMO

Intraoperative margin assessment is needed to reduce the re-excision rate of breast-conserving surgery. One possibility is optical palpation, a tactile imaging technique that maps stress (force applied across the tissue surface) as an indicator of tissue stiffness. Images (optical palpograms) are generated by compressing a transparent silicone layer on the tissue and measuring the layer deformation using optical coherence tomography (OCT). This paper reports, for the first time, the diagnostic accuracy of optical palpation in identifying tumor within 1 mm of the excised specimen boundary using an automated classifier. Optical palpograms from 154 regions of interest (ROIs) from 71 excised tumor specimens were obtained. An automated classifier was constructed to predict the ROI margin status by first choosing a circle diameter, then searching for a location within the ROI where the circle was ≥ 75% filled with high stress (indicating a positive margin). A range of circle diameters and stress thresholds, as well as the impact of filtering out non-dense tissue regions, were tested. Sensitivity and specificity were calculated by comparing the automated classifier results with the true margin status, determined from co-registered histology. 83.3% sensitivity and 86.2% specificity were achieved, compared to 69.0% sensitivity and 79.0% specificity obtained with OCT alone on the same dataset using human readers. Representative optical palpograms show that positive margins containing a range of cancer types tend to exhibit higher stress compared to negative margins. These results demonstrate the potential of optical palpation for margin assessment.

3.
Cancer Res ; 80(8): 1773-1783, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32295783

RESUMO

Inadequate margins in breast-conserving surgery (BCS) are associated with an increased likelihood of local recurrence of breast cancer. Currently, approximately 20% of BCS patients require repeat surgery due to inadequate margins at the initial operation. Implementation of an accurate, intraoperative margin assessment tool may reduce this re-excision rate. This study determined, for the first time, the diagnostic accuracy of quantitative micro-elastography (QME), an optical coherence tomography (OCT)-based elastography technique that produces images of tissue microscale elasticity, for detecting tumor within 1 mm of the margins of BCS specimens. Simultaneous OCT and QME were performed on the margins of intact, freshly excised specimens from 83 patients undergoing BCS and on dissected specimens from 7 patients undergoing mastectomy. The resulting three-dimensional images (45 × 45 × 1 mm) were coregistered with postoperative histology to determine tissue types present in each scan. Data from 12 BCS patients and the 7 mastectomy patients served to build a set of images for reader training. One hundred and fifty-four subimages (10 × 10 × 1 mm) from the remaining 71 BCS patients were included in a blinded reader study, which resulted in 69.0% sensitivity and 79.0% specificity using OCT images, versus 92.9% sensitivity and 96.4% specificity using elasticity images. The quantitative nature of QME also facilitated development of an automated reader, which resulted in 100.0% sensitivity and 97.7% specificity. These results demonstrate high accuracy of QME for detecting tumor within 1 mm of the margin and the potential for this technique to improve outcomes in BCS. SIGNIFICANCE: An optical imaging technology probes breast tissue elasticity to provide accurate assessment of tumor margin involvement in breast-conserving surgery.


Assuntos
Adenocarcinoma Mucinoso/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Margens de Excisão , Mastectomia Segmentar/métodos , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/cirurgia , Adulto , Idoso , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Mastectomia Segmentar/normas , Pessoa de Meia-Idade , Reoperação , Tomografia de Coerência Óptica
4.
J Biophotonics ; 10(5): 690-700, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27618159

RESUMO

Surgical treatment of breast cancer aims to identify and remove all malignant tissue. Intraoperative assessment of tumor margins is, however, not exact; thus, re-excision is frequently needed, or excess normal tissue is removed. Imaging methods applicable intraoperatively could help to reduce re-excision rates whilst minimizing removal of excess healthy tissue. Optical coherence elastography (OCE) has been proposed for use in breast-conserving surgery; however, intraoperative interpretation of complex OCE images may prove challenging. Observations of breast cancer on multiple length scales, by OCE, ultrasound elastography, and atomic force microscopy, have shown an increase in the mechanical heterogeneity of malignant breast tumors compared to normal breast tissue. In this study, a micro-scale mechanical heterogeneity index is introduced and used to form heterogeneity maps from OCE scans of 10 ex vivo human breast tissue samples. Through comparison of OCE, optical coherence tomography images, and corresponding histology, malignant tissue is shown to possess a higher heterogeneity index than benign tissue. The heterogeneity map simplifies the contrast between tumor and normal stroma in breast tissue, facilitating the rapid identification of possible areas of malignancy, which is an important step towards intraoperative margin assessment using OCE.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade , Tomografia de Coerência Óptica , Mama/diagnóstico por imagem , Feminino , Humanos
5.
Biomed Opt Express ; 7(10): 4139-4153, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27867721

RESUMO

Incomplete excision of malignant tissue is a major issue in breast-conserving surgery, with typically 20 - 30% of cases requiring a second surgical procedure arising from postoperative detection of an involved margin. We report advances in the development of a new intraoperative tool, optical coherence micro-elastography, for the assessment of tumor margins on the micro-scale. We demonstrate an important step by conducting whole specimen imaging in intraoperative time frames with a wide-field scanning system acquiring mosaicked elastograms with overall dimensions of ~50 × 50 mm, large enough to image an entire face of most lumpectomy specimens. This capability is enabled by a wide-aperture annular actuator with an internal diameter of 65 mm. We demonstrate feasibility by presenting elastograms recorded from freshly excised human breast tissue, including from a mastectomy, lumpectomies and a cavity shaving.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA