RESUMO
INTRODUCTION: Medtronic's Lead Integrity Alert (LIA) software algorithm is useful for detecting abnormal parameters across various ICD-lead families. However, its utility in the assessment of the Biotronik Linox™ family of high-voltage (HV) leads is unknown. METHODS: We conducted a retrospective cohort study to assess the performance of the LIA algorithm to detect abnormalities and lead failure in Linox ICD-leads. All LIA-enabled Medtronic devices connected to an active Linox lead were included. The alerts were adjudicated by 2 blinded electrophysiologists and correlated with clinical data. RESULTS: Between 2008 and 2012, data from 208 patients with 564 patient-years of follow-up were available for analysis. The median follow-up duration was 32 (IQR 21-41 months). Twenty-one LIA triggers were noted in 20 different patients. The median delay until a positive LIA was 32 months (IQR 21-41 months) postimplant with a 5-year lead survival free from LIA of 76%. Ninety-five percent (19/20) LIA alerts were true lead failures. The most common LIA triggers were short V-V intervals (85%) and nonsustained ventricular tachycardia (85%). Abrupt changes of the ICD-lead impedance occurred in 5/20 triggers. Inappropriate ICD-shocks were strongly associated with a positive LIA (30% vs. 7.4%; P = 0.006). Of the explanted Linox leads 53% had visible abnormalities. The sensitivity, specificity, and positive predictive value for lead failure in the presence of a LIA trigger were 87%, 99.5%, and 95.2%, respectively. CONCLUSIONS: A positive LIA trigger in Biotronik Linox ICD-leads is highly predictive of lead failure. LIA is useful in ongoing surveillance of lead performance.
Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Intervalo Livre de Doença , Eletrocardiografia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Falha de TratamentoRESUMO
BACKGROUND: Social health is a dimension of quality of life, and refers to people's involvement in, and satisfaction with social roles, responsibilities, and activities. The implantable cardioverter-defibrillator is associated with changes in overall quality of life, but little is known about sex differences in individual trajectories of change in social health. METHODS AND RESULTS: We prospectively measured changes in 3 subscales of the SF-36v2 generic health questionnaire (role physical, role emotional, and social functioning), 2 Patient-Reported Outcomes Measurement Information System short forms (satisfaction with participation in social roles and satisfaction with participation in discretionary social activities), and the Florida Patient Acceptance Survey before and at 1, 2, and 6 months after implantation. Individual growth models of temporal change were estimated. The scores of the 6 indicators improved with time. The unconditional model demonstrated significant (fixed effects: P<0.05; covariance parameters: P<0.10) residual variability in the individual trajectories. In the conditional model, men and women differed significantly in their rates of change in the scores of 3 of the 6 measures. Although men's mean scores exceeded women's mean scores on all indicators at baseline (range of relative mean difference: 11.0% to 17.8%), the rate of women's change resulted in a reversal in relative standing at 6 months after implantation, with the mean scores of women exceeding the men's by 4.5% to 5.6%. CONCLUSIONS: Men and women differed in their trajectories of change in social health, both in terms of their starting points (ie, baseline scores) and their rates of change.
Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Qualidade de Vida , Comportamento Social , Adulto , Idoso , Cardioversão Elétrica/efeitos adversos , Emoções , Feminino , Disparidades nos Níveis de Saúde , Humanos , Relações Interpessoais , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Fatores Sexuais , Responsabilidade Social , Inquéritos e Questionários , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. METHODS: A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. OBJECTIVES: To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. RESULTS: DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). CONCLUSIONS: DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.
Assuntos
Desfibriladores Implantáveis/economia , Análise de Falha de Equipamento/economia , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/prevenção & controle , Cuidados Intraoperatórios/estatística & dados numéricos , Padrões de Prática Médica/economia , Sistema de Registros/estatística & dados numéricos , Idoso , Canadá/epidemiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Análise de Falha de Equipamento/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Humanos , Pessoa de Meia-Idade , Padrões de Prática Médica/estatística & dados numéricos , Prevalência , Medição de Risco , Fatores de RiscoRESUMO
INTRODUCTION: Radiofrequency ablation (RFA) has become an accepted therapy for atrial fibrillation (AF). The objective of this study was to perform an economic evaluation of RFA versus antiarrhythmic drug therapy (AAD) as first-line treatment of symptomatic paroxysmal AF. METHODS: To estimate and compare the costs of RFA versus AAD, a decision analytic model was developed using data on AF recurrence, hospitalization rates, AAD use, and treatment crossover rates derived directly from the Randomized Trial of RFA versus AAD as First-Line Treatment of Symptomatic Atrial Fibrillation (RAAFT). Resource utilization was modeled to reflect Canadian clinical practice in AF management. Unit costs of healthcare interactions were based on available Canadian government resources and published literature. Costs were assessed based on intention-to-treat. Total expected costs were computed to include initial treatment, hospital stay, physician fees, diagnostic tests, and outpatient visits. Sensitivity analyses were performed to account for the uncertainties. The study was conducted from the third party payer's perspective and costs are reported in 2005 Canadian dollars with 3% discount rate used in the analysis. RESULTS: During the 2-month blanking period following therapy selection, total average costs for RFA and AAD were $10,465 and $2,556, respectively; at 1-year follow-up, these were $12,823 and $6,053; and total 2-year cumulative total average costs were $15,303 and $14,392. Sensitivity analyses did not alter the results, suggesting the model is robust. CONCLUSIONS: RFA as first-line treatment strategy in patients with symptomatic paroxysmal AF was cost neutral 2 years after the initial procedure compared to AAD.
Assuntos
Antiarrítmicos/economia , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Ablação por Cateter/economia , Ablação por Cateter/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Modelos Econômicos , Fibrilação Atrial/epidemiologia , Canadá/epidemiologia , Simulação por Computador , Análise Custo-Benefício , Feminino , Humanos , Masculino , Resultado do TratamentoRESUMO
INTRODUCTION: There is emerging evidence for clinical superiority of catheter ablation over rate and rhythm control strategies in paroxysmal atrial fibrillation (PAF). The objective of this study was to compare costs related to medical therapy versus catheter ablation for PAF in Ontario (Canada). METHODS: Costs related to medical therapy in the analysis included the cost of anticoagulation, rate and rhythm control medications, noninvasive testing, physician follow-up visits, and hospital admissions, as well as the cost of complications related to this management strategy. Costs related to catheter ablation were assumed to include the cost of the ablation tools (electroanatomic mapping or intracardiac echocardiography-guided pulmonary vein ablation), hospital and physician billings, and costs related to periprocedural medical care and complications. Costs related to these various elements were obtained from the Canadian Registry of Atrial Fibrillation (CARAF), government fee schedules, and published data. Sensitivity analyses looking at a range of initial success rates (50-75%) and late attrition rates (1-5%), prevalence of congestive heart failure (CHF) (20-60%), as well as discounting varying from 3% to 5% per year were performed. RESULTS: The cost of catheter ablation ranged from $16,278 to $21,294, with an annual cost of $1,597 to $2,132. The annual cost of medical therapy ranged from $4,176 to $5,060. Costs of ongoing medical therapy and catheter ablation for PAF equalized at 3.2-8.4 years of follow-up. CONCLUSION: Catheter ablation is a fiscally sensible alternative to medical therapy in PAF with cost equivalence after 4 years.