Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Jpn J Radiol ; 41(8): 843-853, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36811719

RESUMO

PURPOSE: To evaluate left atrial (LA) function in patients with hypertrophic cardiomyopathy (HCM) by LA strain assessment using cardiac computed tomography (CT-derived LA strain). MATERIALS AND METHODS: This was a retrospective study of 34 patients with HCM and 31 non-HCM patients who underwent cardiac computed tomography (CT) using retrospective electrocardiogram-gated mode. CT images were reconstructed every 5% (0-95%) of the RR intervals. CT-derived LA strain (reservoir [LASr], conduit [LASc], and booster pump strain [LASp]) were semi-automatically analyzed using a dedicated workstation. We also measured the left atrial volume index (LAVI) and left ventricular longitudinal strain (LVLS) for the left atrial and ventricular functional parameters to assess the relationship with CT-derived LA strain. RESULTS: CT-derived LA strain significantly correlated with LAVI: r = - 0.69, p < 0.001 for LASr; r = - 0.70, p < 0.001 for LASp; and r = - 0.35, p = 0.004 for LASc. CT-derived LA strain also significantly correlated with LVLS: r = - 0.62, p < 0.001 for LASr; r = - 0.67, p < 0.001 for LASc; and r = - 0.42, p = 0.013 for LASp. CT-derived LA strain in patients with HCM was significantly lower than that in non-HCM patients: LASr (20.8 ± 7.6 vs. 31.7 ± 6.1%, p < 0.001); LASc (7.9 ± 3.4 vs. 14.2 ± 5.3%, p < 0.001); and LASp (12.8 ± 5.7 vs. 17.6 ± 4.3%, p < 0.001). Additionally, CT-derived LA strain showed high reproducibility; inter-observer correlation coefficients were 0.94, 0.90, and 0.89 for LASr, LASc, and LASp, respectively. CONCLUSION: CT-derived LA strain is feasible for quantitative assessment of left atrial function in patients with HCM.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Átrios do Coração/diagnóstico por imagem , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Tomografia
2.
Jpn J Radiol ; 41(2): 142-152, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36227459

RESUMO

PURPOSE: We applied a combination of compressed-sensing (CS) and retrospective motion correction to free-breathing cine magnetic resonance (MR) (FBCS cine MoCo). We validated FBCS cine MoCo by comparing it with breath-hold (BH) conventional cine MR. MATERIALS AND METHODS: Thirty-five volunteers underwent both FBCS cine MoCo and BH conventional cine MR imaging. Twelve consecutive short-axis cine images were obtained. We compared the examination time, image quality and biventricular volumetric assessments between the two cine MR. RESULTS: FBCS cine MoCo required a significantly shorter examination time than BH conventional cine (135 s [110-143 s] vs. 198 s [186-349 s], p < 0.001). The image quality scores were not significantly different between the two techniques (End-diastole: FBCS cine MoCo; 4.7 ± 0.5 vs. BH conventional cine; 4.6 ± 0.6; p = 0.77, End-systole: FBCS cine MoCo; 4.5 ± 0.5 vs. BH conventional cine; 4.5 ± 0.6; p = 0.52). No significant differences were observed in all biventricular volumetric assessments between the two techniques. The mean differences with 95% confidence interval (CI), based on Bland-Altman analysis, were - 0.3 mL (- 8.2 - 7.5 mL) for LVEDV, 0.2 mL (- 5.6 - 5.9 mL) for LVESV, - 0.5 mL (- 6.3 - 5.2 mL) for LVSV, - 0.3% (- 3.5 - 3.0%) for LVEF, - 0.1 g (- 8.5 - 8.3 g) for LVED mass, 1.4 mL (- 15.5 - 18.3 mL) for RVEDV, 2.1 mL (- 11.2 - 15.3 mL) for RVESV, - 0.6 mL (- 9.7 - 8.4 mL) for RVSV, - 1.0% (- 6.5 - 4.6%) for RVEF. CONCLUSION: FBCS cine MoCo can potentially replace multiple BH conventional cine MR and improve the clinical utility of cine MR.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Respiração , Imageamento por Ressonância Magnética/métodos , Suspensão da Respiração , Reprodutibilidade dos Testes
3.
Circ J ; 86(5): 857-865, 2022 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-35197394

RESUMO

BACKGROUND: This study aimed to quantitatively evaluate myocardial perfusion single-photon emission computed tomography (SPECT) using an original analysis tool in the compartment model for detecting regional significant coronary artery disease (CAD).Methods and Results: This study analyzed 41 patients (median age, 76 years) with suspected or known CAD who underwent both dynamic SPECT using 99 mTc-tetrofosmin and invasive coronary angiography. The quantitative analysis was performed using a single-tissue compartment model to evaluate the diagnostic performance of the myocardial flow reserve (MFR) for regional significant CAD, excluding infarcted territories. In the regional analysis, 114 vessels were assessed, of which 31 were diagnosed as significant coronary lesions (≥70% stenosis and/or fraction flow reserve ≤0.8). The MFR of regional significant CAD was significantly lower than that of non-significant CAD (1.11 [0.97-1.31] vs. 1.74 [1.30-2.27]; P<0.001). In the receiver operating characteristic curve analysis, the MFR displayed an area under the curve (AUC) of 0.81. While analyzing each coronary artery territory, the diagnostic performance of the MFR value in the left anterior descending (LAD) artery territory was found to be significantly higher than that found in qualitative assessment (AUC: 0.84 vs. 0.61). CONCLUSIONS: A quantitative analysis of dynamic SPECT data facilitated detecting regional CAD. For the LAD artery, the MFR displayed a higher diagnostic performance than the qualitative assessment of conventional myocardial perfusion SPECT.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Curva ROC , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
J Cardiovasc Magn Reson ; 23(1): 10, 2021 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-33618722

RESUMO

BACKGROUND: Feature tracking (FT) has become an established tool for cardiovascular magnetic resonance (CMR)-based strain analysis. Recently, the compressed sensing (CS) technique has been applied to cine CMR, which has drastically reduced its acquisition time. However, the effects of CS imaging on FT strain analysis need to be carefully studied. This study aimed to investigate the use of CS cine CMR for FT strain analysis compared to conventional cine CMR. METHODS: Sixty-five patients with different left ventricular (LV) pathologies underwent both retrospective conventional cine CMR and prospective CS cine CMR using a prototype sequence with the comparable temporal and spatial resolution at 3 T. Eight short-axis cine images covering the entire LV were obtained and used for LV volume assessment and FT strain analysis. Prospective CS cine CMR data over 1.5 heartbeats were acquired to capture the complete end-diastolic data between the first and second heartbeats. LV volume assessment and FT strain analysis were performed using a dedicated software (ci42; Circle Cardiovasacular Imaging, Calgary, Canada), and the global circumferential strain (GCS) and GCS rate were calculated from both cine CMR sequences. RESULTS: There were no significant differences in the GCS (- 17.1% [- 11.7, - 19.5] vs. - 16.1% [- 11.9, - 19.3; p = 0.508) and GCS rate (- 0.8 [- 0.6, - 1.0] vs. - 0.8 [- 0.7, - 1.0]; p = 0.587) obtained using conventional and CS cine CMR. The GCS obtained using both methods showed excellent agreement (y = 0.99x - 0.24; r = 0.95; p < 0.001). The Bland-Altman analysis revealed that the mean difference in the GCS between the conventional and CS cine CMR was 0.1% with limits of agreement between -2.8% and 3.0%. No significant differences were found in all LV volume assessment between both types of cine CMR. CONCLUSION: CS cine CMR could be used for GCS assessment by CMR-FT as well as conventional cine CMR. This finding further enhances the clinical utility of high-speed CS cine CMR imaging.


Assuntos
Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos
5.
J Cardiol ; 76(3): 259-265, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32359811

RESUMO

BACKGROUND: This study aimed to evaluate the combined diagnostic performance of coronary artery stenosis-subtended myocardial volume (Vsub) and myocardial blood flow (MBFsub) on computed tomography (CT) for detecting obstructive coronary artery disease (CAD) assessed by invasive coronary angiography (ICA) and fractional flow reserve (FFR). METHODS: Thirty-nine patients who underwent coronary CT angiography (CTA) and stress dynamic myocardial CT perfusion (CTP) prior to ICA were enrolled. Obstructive CAD was defined as severe (≥70%) or moderate (30-69%) stenosis with FFR ≤0.8 on ICA. The Vsub was semi-automatically calculated from coronary CTA data using Voronoi diagram-based myocardial segmentation. The standard CT-MBF based on the 17-segment model was calculated using dynamic stress CTP data and deconvolution analysis. The CT-MBFsub was automatically analyzed by integrating the CT-MBF and Voronoi diagram-based myocardial segmentation analyses. The diagnostic performance of combined CT-MBFsub and Vsub assessment was determined using receiver operating characteristic analysis and compared with standard CT-MBF and CT-MBFsub. RESULTS: Of 117 vessels in 39 patients, 72 vessels were suspected of significant stenosis on CTA and 33 vessels had obstructive CAD on ICA and FFR. The sensitivity and specificity for identifying obstructive CAD were 67% and 82% for standard CT-MBF, 70% and 77% for CT-MBFsub, and 85% and 82% for combined CT-MBFsub and Vsub assessment. The area under the receiver operating characteristic curve of the combined CT-MBFsub and Vsub assessment was significantly higher than those of standard CT-MBF and CT-MBFsub (0.89 vs. 0.75, 0.77; p<0.05). CONCLUSIONS: The Vsub may aid in increasing the diagnostic performance of CT-MBFsub for detecting obstructive CAD.


Assuntos
Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Idoso , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade
6.
Clin Imaging ; 56: 93-101, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31026684

RESUMO

BACKGROUND: The relationship between shot-to-shot sampling rates for dynamic myocardial computed tomography perfusion (CTP) and robustness of CTP-derived myocardial blood flow (CT-MBF) is debatable. We retrospectively investigated the influence of a reduced sampling rate for dynamic CTP on CT-MBF computation and diagnostic performance for detecting myocardial perfusion abnormalities. METHODS: Pharmacological stress dynamic whole-heart CTP was performed in 120 patients suspected with coronary artery disease. Dynamic CTP data were obtained for 30 continuous heartbeats during the R-peak to R-peak (1RR) interval on electrocardiography. Three additional datasets were created with sub-sampling acquisitions every 2, 3, and 4 heartbeats from the original dataset as interval times of 2RR, 3RR, and 4RR, respectively. CT-MBF was calculated using deconvolution analysis and determined as the mean value of the whole heart (global CT-MBF) and using the 16-segment model (segmental CT-MBF). The diagnostic performance of segmental CT-MBF for detecting perfusion abnormalities was compared to that of cardiac magnetic resonance imaging as the gold standard in 32 of 120 patients. These results were compared among the four CTP datasets. RESULTS: Global CT-MBFs for 1RR, 2RR, 3RR, and 4RR sampling were 1.57 ±â€¯0.34, 1.54 ±â€¯0.36, 1.51 ±â€¯0.37, and 1.41 ±â€¯0.33 mL/g/min, respectively. Areas under the receiver operating characteristic curves of segmental CT-MBF for 1RR, 2RR, 3RR, and 4RR sampling were 0.84, 0.83, 0.79, and 0.76, respectively (1RR versus [vs.] 2RR, non-significant; 1RR vs. 3RR or 4RR, p < 0.05). CONCLUSION: CT-MBF with 2RR sampling has similar performance with regard to quantification and detecting myocardial perfusion abnormalities as that with 1RR sampling.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Masculino , Imagem de Perfusão do Miocárdio/métodos , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Jpn J Radiol ; 36(7): 444-449, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29767297

RESUMO

PURPOSE: We evaluated the associations between gestational age (GA) and lung-to-liver signal intensity ratio (LLSIR) and fetal lung volume (FLV) using magnetic resonance imaging (MRI). Moreover, we evaluated the reproducibility of these measurements. MATERIALS AND METHODS: LLSIR and FLV were measured using single-shot fast spin-echo MRI in 88 consecutive fetuses. The Spearman test was used to assess the relationships between (1) LLSIR and GA, and (2) FLV and GA in 81 fetuses without lung abnormalities. Intra- and inter-observer reliabilities were assessed using intra-class correlation coefficients (ICCs). RESULTS: Overall, GA and LLSIR were significantly correlated (r = 0.62, p < 0.001). However, GA and LLSIR were only significantly correlated during the third trimester (before third trimester: r = 0.39, p = 0.08; during third trimester: r = 0.46, p < 0.001). Overall, GA and FLV were significantly correlated (r = 0.72, p < 0.001). FLV was significantly correlated with GA before (r = 0.86, p < 0.001) and during the third trimester (r = 0.47, p < 0.001). All ICCs were above 0.90. CONCLUSIONS: LLSIR and FLV are useful for the assessment of fetal lung maturity and are highly reproducible. Before the third trimester, FLV is more suitable than LLSIR for the evaluation of fetal lung maturity.


Assuntos
Pulmão/anatomia & histologia , Pulmão/embriologia , Imageamento por Ressonância Magnética/métodos , Feminino , Idade Gestacional , Humanos , Fígado/anatomia & histologia , Fígado/diagnóstico por imagem , Fígado/embriologia , Pulmão/diagnóstico por imagem , Tamanho do Órgão , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Circ J ; 81(10): 1463-1468, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28515392

RESUMO

BACKGROUND: Compressed sensing (CS) cine magnetic resonance imaging (MRI) has the advantage of being inherently insensitive to respiratory motion. This study compared the accuracy of free-breathing (FB) CS and breath-hold (BH) standard cine MRI for left ventricular (LV) volume assessment.Methods and Results:Sixty-three patients underwent cine MRI with both techniques. Both types of images were acquired in stacks of 8 short-axis slices (temporal/spatial resolution, 41 ms/1.7×1.7×6 mm3) and compared for ejection fraction, end-diastolic and systolic volumes, stroke volume, and LV mass. Both BH standard and FB CS cine MRI provided acceptable image quality for LV volumetric analysis (score ≥3) in all patients (4.7±0.5 and 3.7±0.5, respectively; P<0.0001) and had good agreement on LV functional assessment. LV mass, however, was slightly underestimated on FB CS cine MRI (median, IQR: BH standard, 83.8 mL, 64.7-102.7 mL; FB CS, 79.0 mL, 66.0-101.0 mL; P=0.0006). The total acquisition times for BH standard and FB CS cine MRI were 113±7 s and 24±4 s, respectively (P<0.0001). CONCLUSIONS: Despite underestimation of LV mass, FB CS cine MRI is a clinically useful alternative to BH standard cine MRI in patients with impaired BH capacity.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
J Cardiovasc Magn Reson ; 18(1): 50, 2016 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-27553656

RESUMO

BACKGROUND: Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. METHODS: Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 × 1.7 mm(2)) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., "nondiagnostic"] to 5 [i.e., "excellent"]) and quantitative analysis of the LV volume measurements. RESULTS: The total examination time was 113 ± 7 s for standard cine CMR and 24 ± 4 s for CS cine CMR (p < 0.0001). The CS cine image quality was slightly lower than standard cine (4.8 ± 0.5 for standard vs. 4.4 ± 0.5 for CS; p < 0.0001). However, all image quality scores for CS cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland-Altman analysis, were 1.3 mL (95 % CI, -14.6 - 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, -9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI, -10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, -11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, -4.8 - 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from -4.8 - 1.6 % and from -7.3 - 9.3 %, respectively, with slopes of the regressions ranging 0.88-1.0 and 0.86-1.03, respectively. CONCLUSIONS: Single-breath-hold full cardiac cycle CS real-time cine CMR could evaluate LV volume with excellent accuracy. It may replace multi-breath-hold standard cine CMR.


Assuntos
Suspensão da Respiração , Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Cardiopatias/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA