Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
PLoS Negl Trop Dis ; 15(6): e0009467, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34077423

RESUMO

BACKGROUND: In South Korea, the number of Q fever cases has rapidly increased since 2015. Therefore, this study aimed to characterize the epidemiological and clinical features of Q fever in South Korea between 2011 and 2017. METHODS/PRINCIPAL FINDINGS: We analyzed the epidemiological investigations and reviewed the medical records from all hospitals that had reported at least one case of Q fever from 2011 to 2017. We also conducted an online survey to investigate physicians' awareness regarding how to appropriately diagnose and manage Q fever. The nationwide incidence rate of Q fever was annually 0.07 cases per 100,000 persons. However, there has been a sharp increase in its incidence, reaching up to 0.19 cases per 100,000 persons in 2017. Q fever sporadically occurred across the country, with the highest incidences in Chungbuk (0.53 cases per 100,000 persons per year) and Chungnam (0.27 cases per 100,000 persons per year) areas. Patients with acute Q fever primarily presented with mild illnesses such as hepatitis (64.5%) and isolated febrile illness (24.0%), whereas those with chronic Q fever were likely to undergo surgery (41.2%) and had a high mortality rate (23.5%). Follow-up for 6 months after acute Q fever was performed by 24.0% of the physician respondents, and only 22.3% of them reported that clinical and serological evaluations were required after acute Q fever diagnosis. CONCLUSIONS: Q fever is becoming an endemic disease in the midwestern area of South Korea. Given the clinical severity and mortality of chronic Q fever, physicians should be made aware of appropriate diagnosis and management strategies for Q fever.


Assuntos
Médicos/psicologia , Febre Q/diagnóstico , Adolescente , Adulto , Conscientização , Criança , Pré-Escolar , Doenças Endêmicas , Feminino , Humanos , Incidência , Lactente , Masculino , Pessoa de Meia-Idade , Febre Q/epidemiologia , Febre Q/psicologia , República da Coreia/epidemiologia , Estações do Ano , Adulto Jovem
2.
Biosens Bioelectron ; 91: 128-135, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28006679

RESUMO

A disposable microfluidic amperometric dual-sensor was developed for the detection of glycated hemoglobin (HbA1C) and total hemoglobin (Hb), separately, in a finger prick blood sample. The accurate level of total Hb was determined through the measurements of the cathodic currents of total Hb catalyzed by a toluidine blue O (TBO)-modified working electrode. Subsequently, after washing unbound Hb in the fluidic channel of dual sensor with PBS, the cathodic current by only HbA1C captured on aptamer was monitored using another aptamer/TBO-modified working electrode in the channel. To modify the sensor probe, poly(2,2´:5´,5″-terthiophene-3´-p-benzoic acid) and a multi-wall carbon nanotube (MWCNT) composite layer (pTBA@MWCNT) was electropolymerized on a screen printed carbon electrode (SPCE), followed by immobilization of TBO for the total Hb probe and aptamer/TBO for the HbA1C probe, respectively. The characterization of each sensor surface was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), field-emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The experimental conditions affecting the analytical signal were optimized in terms of the amount of TBO, pH, temperature, binding time, applied potential, and the content ratio of monomer and MWCNT. The dynamic ranges of Hb and HbA1C were from 0.1 to 10µM and from 0.006 to 0.74µM, with detection limits of 82(±4.2)nM and 3.7(±0.8)nM, respectively. The reliability of the proposed microfluidic dual-sensor for a finger prick blood sample (1µL) was evaluated in parallel with a conventional method (HPLC) for point-of-care analysis.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Hemoglobinas Glicadas/análise , Hemoglobinas/análise , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Biossensoriais/economia , Corantes/química , Técnicas Eletroquímicas/economia , Eletrodos , Humanos , Técnicas Analíticas Microfluídicas/economia , Modelos Moleculares , Sistemas Automatizados de Assistência Junto ao Leito/economia , Reprodutibilidade dos Testes , Cloreto de Tolônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA