Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 48(1): 201-210, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36261505

RESUMO

PURPOSE: To investigate the effects of deep learning-based imaging reconstruction (DLR) on the image quality of MRI of rectal cancer after chemoradiotherapy (CRT), and its accuracy in diagnosing pathological complete responses (pCR). METHODS: We included 39 patients (men: women, 21:18; mean age ± standard deviation, 59.1 ± 9.7 years) with mid-to-lower rectal cancer who underwent a long-course of CRT and high-resolution rectal MRIs between January 2020 and April 2021. Axial T2WI was reconstructed using the conventional method (MRIconv) and DLR with two different noise reduction factors (MRIDLR30 and MRIDLR50). The signal-to-noise ratio (SNR) of the tumor was measured. Two experienced radiologists independently made a blind assessment of the complete response on MRI. The sensitivity and specificity for pCR were analyzed using a multivariable logistic regression analysis with generalized estimating equations. RESULTS: Thirty-four patients did not have a pCR whereas five (12.8%) had pCR. Compared with the SNR of MRIconv (mean ± SD, 7.94 ± 1.92), MRIDLR30 and MRIDLR50 showed higher SNR (9.44 ± 2.31 and 11.83 ± 3.07, respectively) (p < 0.001). Compared to MRIconv, MRIDLR30 and MRIDLR50 showed significantly higher specificity values (p < 0.036) while the sensitivity values were not significantly different (p > 0.301). The sensitivity and specificity for pCR were 48.9% and 80.8% for MRIconv; 48.9% and 88.2% for MRIDLR30; and 38.8% and 86.7% for MRIDLR50, respectively. CONCLUSION: DLR produced MR images with higher resolution and SNR. The specificity of MRI for identification of pCR was significantly higher with DLR than with conventional MRI.


Assuntos
Aprendizado Profundo , Imageamento por Ressonância Magnética , Neoplasias Retais , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Terapia Neoadjuvante , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Sensibilidade e Especificidade
2.
Front Oncol ; 13: 1337626, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38173837

RESUMO

Introduction: We analyzed daily pre-treatment- (PRE) and real-time motion monitoring- (MM) MRI scans of patients receiving definitive prostate radiotherapy (RT) with 1.5 T MRI guidance to assess interfractional and intrafractional variability of the prostate and suggest optimal planning target volume (PTV) margin. Materials and methods: Rigid registration between PRE-MRI and planning CT images based on the pelvic bone and prostate anatomy were performed. Interfractional setup margin (SM) and interobserver variability (IO) were assessed by comparing the centroid values of prostate contours delineated on PRE-MRIs. MM-MRIs were used for internal margin (IM) assessment, and PTV margin was calculated using the van Herk formula. Results: We delineated 400 prostate contours on PRE-MRI images. SM was 0.57 ± 0.42, 2.45 ± 1.98, and 2.28 ± 2.08 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively, after bone localization and 0.76 ± 0.57, 1.89 ± 1.60, and 2.02 ± 1.79 mm in the LR, AP, and SI directions, respectively, after prostate localization. IO was 1.06 ± 0.58, 2.32 ± 1.08, and 3.30 ± 1.85 mm in the LR, AP, and SI directions, respectively, after bone localization and 1.11 ± 0.55, 2.13 ± 1.07, and 3.53 ± 1.65 mm in the LR, AP, and SI directions, respectively, after prostate localization. Average IM was 2.12 ± 0.86, 2.24 ± 1.07, and 2.84 ± 0.88 mm in the LR, AP, and SI directions, respectively. Calculated PTV margin was 2.21, 5.16, and 5.40 mm in the LR, AP, and SI directions, respectively. Conclusions: Movements in the SI direction were the largest source of variability in definitive prostate RT, and interobserver variability was a non-negligible source of margin. The optimal PTV margin should also consider the internal margin.

3.
J Nucl Med ; 63(10): 1586-1591, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35086893

RESUMO

We aimed to explore whether the imaging of antiporter system xC - of immune cells with (4S)-4-(3-18F-fluoropropyl)-l-glutamate (18F-FSPG) PET can assess inflammatory bowel disease (IBD) activity in murine models and patients (NCT03546868). Methods: 18F-FSPG PET imaging was performed to assess IBD activity in mice with dextran sulfate sodium-induced and adoptive T-cell transfer-induced IBD and a cohort of 20 patients at a tertiary care center in South Korea. Immunohistochemical analysis of system xC - and cell surface markers was also studied. Results: Mice with experimental IBD showed increased intestinal 18F-FSPG uptake and xCT expression in cells positive (+) for CD11c, F4/80, and CD3 in the lamina propria, increases positively associated with clinical and pathologic disease activity. 18F-FSPG PET studies in patients, most of whom were clinically in remission or had mildly active IBD, showed that PET imaging was sufficiently accurate in diagnosing endoscopically active IBD and remission in patients and bowel segments. 18F-FSPG PET correctly identified all 9 patients with superficial or deep ulcers. Quantitative intestinal 18F-FSPG uptake was strongly associated with endoscopic indices of IBD activity. The number of CD68+xCT+ and CD3+xCT+ cells in 22 bowel segments from patients with ulcerative colitis and the number of CD68+xCT+ cells in 7 bowel segments from patients with Crohn disease showed a significant positive association with endoscopic indices of IBD activity. Conclusion: The assessment of system xC - in immune cells may provide diagnostic information on the immune responses responsible for chronic active inflammation in IBD. 18F-FSPG PET imaging of system xC - activity may noninvasively assess the IBD activity.


Assuntos
Ácido Glutâmico , Doenças Inflamatórias Intestinais , Animais , Antiporters , Sulfato de Dextrana , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Camundongos , Tomografia por Emissão de Pósitrons/métodos
4.
J Appl Clin Med Phys ; 23(2): e13480, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34837723

RESUMO

PURPOSE: The purpose of this study was to investigate the matching error that occurs when the Mobius3D fingerprinting system is applied in conjunction with an Elekta linear accelerator (LINAC) and to offer an acceptable and alternative method for circumventing this problem. MATERIAL AND METHODS: To avoid the multileaf collimator (MLC) conflicting error in the Mobius3D fingerprinting system, we developed an in-house program to move the MLC in the Digital Imaging and Communications in Medicine (DICOM) radiotherapy (RT)-Plan to pertinent positions, considering the relationship between log data and planned data. The re-delivered log files were calculated in the Mobius3D system, and the results were compared with those of corrected data (i.e., we analyzed a pair of re-collected log data and the previous DICOM RT-Plan data). The results were then evaluated by comparing several items, such as point dose errors, gamma index (GI) passing rates, and MLC root-mean-square (RMS) values. RESULTS: For the point dose error, the maximum difference found was below 2.0%. In the case of GI analysis of all plans, the maximum difference in the passing rates was below 1.4%. The statistical results obtained using a paired Student's t-test showed that there were no significant differences within the uncertainty. In the case of the RMS test, the maximum difference found was approximately 0.08 mm. CONCLUSIONS: Our results showed that all the mismatched log files were sufficiently acceptable within the uncertainty. We conclude that the matching error obtained when applying Mobius3D to an Elekta LINAC may be addressed using a simple modification of the fingerprinting system, and we expect that our study findings will help vendors resolve this issue in the near future.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Raios gama , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica
5.
World J Clin Cases ; 9(24): 6999-7008, 2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34540955

RESUMO

BACKGROUND: The microsatellite instability (MSI) test and immunohistochemistry (IHC) are widely used to screen DNA mismatch repair (MMR) deficiency in sporadic colorectal cancer (CRC). For IHC, a two-antibody panel of MLH1 and MSH2 or four-antibody panel of MLH1, MSH2, PMS2, and MSH6 are used. In general, MSI is known as a more accurate screening test than IHC. AIM: To compare two- and four-antibody panels of IHC in terms of accuracy and cost benefit on the basis of MSI testing for detecting MMR deficiency. METHODS: We retrospectively analyzed patients with CRC who underwent curative surgery between 2015 and 2017 at a tertiary referral center. Both IHC with four antibodies and MSI tests were routinely performed. The sensitivity and specificity of a four- and two types of two-antibody panels (PMS2/MSH6 and MLH1/MSH2) were compared on the basis of MSI testing for detecting MMR deficiency. RESULTS: High-frequency MSI was found in 5.5% (n = 193) of the patients (n = 3486). The sensitivities of the four- and two types of two-antibody panels were 97.4%, 92.2%, and 87.6%, respectively. The specificities of the three types of panels did not differ significantly (99.6% for the four-antibody and PMS2/MSH6 panels, 99.7% for the MLH1/MSH2 panel). Based on Cohen's kappa statistic (κ), four- and two-antibody panels were in almost perfect agreement with the MSI test (κ > 0.9). The costs of the MSI test and the four- and two-antibody panels of IHC were approximately $200, $160, and $80, respectively. CONCLUSION: Considering the cost of the four-antibody panel IHC compared to that of the two-antibody panel IHC, a two-antibody panel of PMS2/MSH6 might be the best choice in terms of balancing cost-effectiveness and accuracy.

6.
J Neuroeng Rehabil ; 18(1): 129, 2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-34461938

RESUMO

BACKGROUND: Human beings can enhance their distance running performance with the help of assistive devices. Although several such devices are available, they are heavy and bulky, which limits their use in everyday activities. In this study, we developed a lightweight running assistive device with a low-profile design. The device applies a flexion moment to the hip according to the hip extension within a specific range of motion to assist running. METHODS: A passive exosuit was fabricated using textile materials and elastic bands. The deformation of the suit was measured and compensated for in the design. The fabricated suit was tested on eight participants (age: 24.4 ± 3.8 y; height: 1.72 ± 0.05 m; weight: 74.5 ± 6.1 kg) who were instructed to run on a treadmill at a speed of 2.5 m/s. Through indirect calorimetry, the metabolic rate was measured for the no-suit condition and three band conditions. Variations in the spatiotemporal parameters were measured using a motion capture system and force-sensing resistors (FSRs). RESULTS: When using the fabricated device, seven out of the eight participants exhibited a reduced metabolic rate in at least one of the three band conditions. An average reduction of - 4.7 ± 1.4% (mean ± standard error of the mean (s.e.m.), two-sided paired t-test, p = 0.017) was achieved when using the best-fitting bands compared to the average of the two no-suit conditions. No statistically significant changes were observed in the spatiotemporal parameters, except for the stance duration in the medium assistance force condition. CONCLUSIONS: The proposed passive exosuit, which has a low weight of 609 g and small extrusion of 2.5 cm from the body in standing posture, can reduce the metabolic rate during running. The proposed device can potentially be used every day owing to its low-profile design and low weight, thereby overcoming the limitations of existing portable devices targeting the hip joints.


Assuntos
Exoesqueleto Energizado , Robótica , Corrida , Adulto , Fenômenos Biomecânicos , Humanos , Caminhada , Adulto Jovem
7.
Korean J Radiol ; 22(9): 1451-1461, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34132075

RESUMO

OBJECTIVE: Adequate methods of combining T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) to assess complete response (CR) to chemoradiotherapy (CRT) for rectal cancer are obscure. We aimed to determine an algorithm for combining T2WI and DWI to optimally suggest CR on MRI using visual assessment. MATERIALS AND METHODS: We included 376 patients (male:female, 256:120; mean age ± standard deviation, 59.7 ± 11.1 years) who had undergone long-course CRT for rectal cancer and both pre- and post-CRT high-resolution rectal MRI during 2017-2018. Two experienced radiologists independently evaluated whether a tumor signal was absent, representing CR, on both post-CRT T2WI and DWI, and whether the pre-treatment DWI showed homogeneous hyperintensity throughout the lesion. Algorithms for combining T2WI and DWI were as follows: 'AND,' if both showed CR; 'OR,' if any one showed CR; and 'conditional OR,' if T2WI showed CR or DWI showed CR after the pre-treatment DWI showed homogeneous hyperintensity. Their efficacies for diagnosing pathologic CR (pCR) were determined in comparison with T2WI alone. RESULTS: Sixty-nine patients (18.4%) had pCR. AND had a lower sensitivity without statistical significance (vs. 62.3% [43/69]; 59.4% [41/69], p = 0.500) and a significantly higher specificity (vs. 87.0% [267/307]; 90.2% [277/307], p = 0.002) than those of T2WI. Both OR and conditional OR combinations resulted in a large increase in sensitivity (vs. 62.3% [43/69]; 81.2% [56/69], p < 0.001; and 73.9% [51/69], p = 0.008, respectively) and a large decrease in specificity (vs. 87.0% [267/307]; 57.0% [175/307], p < 0.001; and 69.1% [212/307], p < 0.001, respectively) as compared with T2WI, ultimately creating additional false interpretations of CR more frequently than additional identification of patients with pCR. CONCLUSION: AND combination of T2WI and DWI is an appropriate strategy for suggesting CR using visual assessment of MRI after CRT for rectal cancer.


Assuntos
Terapia Neoadjuvante , Neoplasias Retais , Idoso , Quimiorradioterapia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Sensibilidade e Especificidade
8.
Phys Eng Sci Med ; 43(3): 1069-1075, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32700205

RESUMO

This study assesses the dosimetric leaf gap (DLG) correction factor in Mobius3D commissioning affected by a couch top platform and calculates the optimal DLG value according to the point dose difference function. DLG optimizations were performed for 3 LINAC machines and a total of 30 patient volumetric modulated arc therapy plans (i.e., 10 plans per each LINAC). Point dose calculations were performed using an automatic dose calculation system in Mobius3D as well as Mobis3D calculation using a Mobius Verification Phantom (MVP)-based quality assurance plan with a carbon fiber couch top. Subsequently, the results were compared with measurement data. The averaged point dose measured for the MVP with a couch top decreased by approximately 2% relative to that without the couch top. The average of the optimal DLG factors increased by 1.153 mm due to the couch top effect for a dose decrease of 2% at the measured point. In the procedure of Mobius beam commissioning, users should adjust the DLG correction factor using a specific phantom (including MVP) with a couch top structure. If the DLG optimization were performed by using MVP automatic dose calculation system, the factor should be increased by approximately 1.2 mm per 2% dose difference considering user's couch top effect.


Assuntos
Algoritmos , Dosagem Radioterapêutica , Relação Dose-Resposta à Radiação , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
9.
J Laparoendosc Adv Surg Tech A ; 27(4): 375-382, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28186429

RESUMO

BACKGROUND: One of the perceived major drawbacks of minimally invasive techniques has always been its cost. This is especially true for the robotic approach and is one of the main reasons that has prevented its wider acceptance among hospitals and surgeons. The aim of our study was to evaluate the clinical outcomes and economic impact of robotic and open liver surgery in a single institution. METHODS: Sixty-eight robotic and 55 open hepatectomies were performed at our institution between January 1, 2009 and December 31, 2013. Demographics, perioperative data, and postoperative outcomes were collected and compared between the two groups. An independent company performed the financial analysis. The economic parameters comprised direct variable costs, direct fixed costs, and indirect costs. RESULTS: Mean estimated blood loss was significantly less in the robotic group (438 versus 727.8 mL; P = .038). Overall morbidity was significantly lower in the robotic group (22% versus 40%; P = .047). Clavien III/IV complications were also lower, with 4.4% in the robotic versus 16.3% in the open group (P = .043). The length of stay in the intensive care unit (ICU) was shorter for patients who underwent a robotic procedure (2.1 versus 3.3 days; P = .004). The average total cost, including readmissions, was $37,518 for robotic surgery and $41,948 for open technique. CONCLUSIONS: Robotic liver resections had less overall morbidity, ICU, and hospital stay. This translates into decreased average costs for robotic surgery. These procedures are financially comparable to open resections and do not represent a financial burden to the hospital.


Assuntos
Custos de Cuidados de Saúde , Hepatectomia/métodos , Tempo de Internação/estatística & dados numéricos , Fígado/cirurgia , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Robóticos/métodos , Adulto , Idoso , Feminino , Hepatectomia/economia , Humanos , Unidades de Terapia Intensiva/economia , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/economia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/economia , Resultado do Tratamento , Adulto Jovem
10.
Sci Total Environ ; 470-471: 1553-7, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23928371

RESUMO

The reductive debromination of polybrominated diphenyl ethers (PBDEs) by nanoscale zerovalent iron (nZVI) has proven to be a successful remediation approach. This study simulates the congener profiles and overall ecotoxicological impact of PBDE debromination by nZVI. The relationship between the calculated redox potential values and PBDE debromination rates was sufficiently strong to generate a satisfactory predictive capacity, which was further used to develop a quantitative structure-activity relationship (QSAR) model for the determination of the PBDE debromination patterns and dominant pathways. The predicted results of deca-BDE debromination showed that it would completely disappear within 30 days, but its lower brominated products, particularly tri- to penta-homologues, could exist in the environment even after 5 years. Formation and accumulation of more toxic, low brominated congeners through deca-BDE debromination suggest that deca-BDE may pose prolonged environmental risks. Changes in the toxic equivalent (TEQ) values during deca-BDE debromination parallel the occurrence and transformation of specific low brominated congeners with dioxin-like potency.


Assuntos
Poluentes Ambientais/química , Retardadores de Chama/análise , Éteres Difenil Halogenados/química , Ferro/química , Nanopartículas Metálicas/química , Modelos Químicos , Éteres Difenil Halogenados/análise , Relação Quantitativa Estrutura-Atividade , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA