Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Med ; 10(11)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200470

RESUMO

The aim of this prospective randomized, double-masked, placebo-controlled, multicenter study was to analyze the surgeon's individual assessment of tissue quality during pelvic floor surgery in postmenopausal women pre-treated with local estrogen therapy (LET) or placebo cream. Secondary outcomes included intraoperative and early postoperative course of the two study groups. Surgeons, blinded to patient's preoperative treatment, completed an 8-item questionnaire after each prolapse surgery to assess tissue quality as well as surgical conditions. Our hypothesis was that there is no significant difference in individual surgical assessment of tissue quality between local estrogen or placebo pre-treatment. Multivariate logistic regression analysis was performed to identify independent risk factors for intra- or early postoperative complications. Out of 120 randomized women, 103 (86%) remained for final analysis. Surgeons assessed the tissue quality similarity in cases with or without LET, representing no statistically significant differences concerning tissue perfusion, tissue atrophy, tissue consistency, difficulty of dissection and regular pelvic anatomy. Regarding pre-treatment, the rating of the surgeon correlated significantly with LET (r = 0.043), meaning a correct assumption of the surgeon. Operative time, intraoperative blood loss, occurrence of intraoperative complications, total length of stay, frequent use of analgesics and rate of readmission did not significantly differ between LET and placebo pre-treatment. The rate of defined postoperative complications and use of antibiotics was significantly more frequent in patients without LET (p = 0.045 and p = 0.003). Tissue quality was similarly assessed in cases with or without local estrogen pre-treatment, but it seems that LET prior to prolapse surgery may improve vaginal health as well as tissue-healing processes, protecting these patients from early postoperative complications.

2.
Pediatr Res ; 90(2): 452-458, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33339964

RESUMO

BACKGROUND: Thrombelastometry, allowing timely assessment of global hemostatic function, is increasingly used to guide hemostatic interventions in bleeding patients. Reference values are available for adults and children, including infants but not neonates immediately after birth. METHODS: Neonates were grouped as preterm (30 + 0 to 36 + 6 weeks/days) and term (37 + 0 to 39 + 6 weeks/days). Blood samples were drawn from the umbilical cord immediately after cesarean section and analyzed by thrombelastometry. Reference ranges were determined for the extrinsic and intrinsic coagulation pathways, fibrin polymerization, and hyperfibrinolysis detection. RESULTS: All extrinsically activated test parameters, but maximum lysis (P = 0.139) differed significantly between both groups (P ≤ 0.001). Maximum clot firmness in the fibrin polymerization test was comparable (P = 0.141). All intrinsically activated test parameters other than coagulation time (P = 0.537) and maximum lysis (P = 0.888) differed significantly (P < 0.001), and so did all aprotinin-related test parameters (P ≤ 0.001) but maximum lysis (P = 0.851). CONCLUSIONS: This is the first study to identify reference ranges for thrombelastometry in preterm and term neonates immediately after birth. We also report differences in clot initiation and clot strength in neonates born <37 versus ≤40 weeks of gestation, mirroring developmental hemostasis. IMPACT: Impact: This prospective observational study is the first to present reference ranges in preterm and term infants for all types of commercially available tests of thrombelastometry, notably also including the fibrin polymerization test. IMPORTANCE: Viscoelastic coagulation assays such as thrombelastometry have become integral to the management of perioperative bleeding by present-day standards. Reference values are available for adults, children, and infants but not for neonates. Key message: Clot initiation and formation was faster and clot strength higher in the term than in the preterm group. Parameters of thrombelastometry obtained from cord blood do not apply interchangeably to preterm and term neonates.


Assuntos
Coagulação Sanguínea , Sangue Fetal/metabolismo , Fibrina/metabolismo , Recém-Nascido Prematuro/sangue , Testes Imediatos/normas , Nascimento a Termo/sangue , Tromboelastografia/normas , Biomarcadores/sangue , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência
3.
PLoS One ; 9(10): e111139, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25360698

RESUMO

BACKGROUND: Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. METHODS: Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany) measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of 'normal' extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries). BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student's t-test and multiple linear regression. RESULTS: In 71 females aged 45 ± 15 years with body weight 67 ± 13 kg and Duration of anesthesia 154 ± 69 minutes [corrected] duration of anaesthesia 154 ± 68 min, pre- to postoperative fluid overload increased from -0.7 ± 1.1 L to 0.1 ± 1.0 L, corresponding to -5.1 ± 7.5% and 0.8 ± 6.7% of normal extracellular volume, respectively (both p<0.001), after patients had received 1.9 ± 0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.3 ± 0.2 L [corrected]. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15). Net perioperative fluid balance (administered fluid volume minus urinary excretion) was significantly associated with change in extracellular volume (r(2) = 0.65), but was not associated with change in intracellular volume (r(2) = 0.01). CONCLUSIONS: Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded plausible results and may become useful to guide intraoperative fluid therapy in future studies.


Assuntos
Anestesia Geral , Composição Corporal , Líquidos Corporais/química , Adulto , Idoso , Líquidos Corporais/metabolismo , Espectroscopia Dielétrica , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Pessoa de Meia-Idade , Sinais Vitais , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA