Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Nat Protoc ; 17(11): 2570-2619, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36002768

RESUMO

Single-molecule localization microscopy (SMLM) leverages the power of modern optics to unleash ultra-precise structural nanoscopy of complex biological machines in their native environments as well as ultra-sensitive and high-throughput medical diagnostics with the sensitivity of a single molecule. To achieve this remarkable speed and resolution, SMLM setups are either built by research laboratories with strong expertise in optical engineering or commercially sold at a hefty price tag. The inaccessibility of SMLM to life scientists for technical or financial reasons is detrimental to the progress of biological and biomedical discoveries reliant on super-resolution imaging. In this work, we present the NanoPro, an economic, high-throughput, high-quality and easy-to-assemble SMLM for super-resolution imaging. We show that our instrument performs similarly to the most expensive, best-in-class commercial microscopes and rivals existing open-source microscopes at a lower price and construction complexity. To facilitate its wide adoption, we compiled a step-by-step protocol, accompanied by extensive illustrations, to aid inexperienced researchers in constructing the NanoPro as well as assessing its performance by imaging ground-truth samples as small as 20 nm. The detailed visual instructions make it possible for students with little expertise in microscopy engineering to construct, validate and use the NanoPro in <1 week, provided that all components are available.


Assuntos
Microscopia , Imagem Individual de Molécula , Humanos , Imagem Individual de Molécula/métodos
3.
Biophys Rep (N Y) ; 2(1): None, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35299715

RESUMO

Super-resolution microscopy allows complex biological assemblies to be observed with remarkable resolution. However, the presence of uneven Gaussian-shaped illumination hinders its use in quantitative imaging or high-throughput assays. Methods developed to circumvent this problem are often expensive, hard to implement, or not applicable to total internal reflection fluorescence imaging. We herein demonstrate a cost-effective method to overcome these challenges using a small square-core multimodal optical fiber as the coupler. We characterize our method with synthetic, recombinant, and cellular systems imaged under total internal reflection fluorescence and highly inclined and laminated optical sheet illuminations to demonstrate its ability to produce highly uniform images under all conditions.

4.
Biophys J ; 118(6): 1261-1269, 2020 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-32075748

RESUMO

Cell-cell contacts often underpin signaling between cells. For immunology, the binding of a T cell receptor to an antigen-presenting pMHC initiates downstream signaling and an immune response. Although this contact is mediated by proteins on both cells creating interfaces with gap sizes typically around 14 nm, many, often contradictory observations have been made regarding the influence of the contact on parameters such as the binding kinetics, spatial distribution, and diffusion of signaling proteins within the contact. Understanding the basic physical constraints on probes inside this crowded environment will help inform studies on binding kinetics and dynamics of signaling of relevant proteins in the synapse. By tracking quantum dots of different dimensions for extended periods of time, we have shown that it is possible to obtain the probability of a molecule entering the contact, the change in its diffusion upon entry, and the impact of spatial heterogeneity of adhesion protein density in the contact. By analyzing the contacts formed by a T cell interacting with adhesion proteins anchored to a supported lipid bilayer, we find that probes are excluded from contact entry in a size-dependent manner for gap-to-probe differences of 4.1 nm. We also observed probes being trapped inside the contact and a decrease in diffusion of up to 85% in dense adhesion protein contacts. This approach provides new, to our knowledge, insights into the nature of cell-cell contacts, revealing that cell contacts are highly heterogeneous because of topography- and protein-density-related processes. These effects are likely to profoundly influence signaling between cells.


Assuntos
Receptores de Antígenos de Linfócitos T , Linfócitos T , Difusão , Cinética , Transdução de Sinais
5.
Anal Chem ; 86(17): 8603-12, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25105347

RESUMO

It is of significant biophysical interest to obtain accurate intramolecular distance information and population sizes from single-molecule Förster resonance energy transfer (smFRET) data obtained from biomolecules in solution. Experimental methods of increasing cost and complexity are being developed to improve the accuracy and precision of data collection. However, the analysis of smFRET data sets currently relies on simplistic, and often arbitrary methods, for the selection and denoising of fluorescent bursts. Although these methods are satisfactory for the analysis of simple, low-noise systems with intermediate FRET efficiencies, they display systematic inaccuracies when applied to more complex systems. We have developed an inference method for the analysis of smFRET data from solution studies based on rigorous model-based Bayesian techniques. We implement a Monte Carlo Markov chain (MCMC) based algorithm that simultaneously estimates population sizes and intramolecular distance information directly from a raw smFRET data set, with no intermediate event selection and denoising steps. Here, we present both our parametric model of the smFRET process and the algorithm developed for data analysis. We test the algorithm using a combination of simulated data sets and data from dual-labeled DNA molecules. We demonstrate that our model-based method systematically outperforms threshold-based techniques in accurately inferring both population sizes and intramolecular distances.


Assuntos
DNA/química , Transferência Ressonante de Energia de Fluorescência , Algoritmos , Teorema de Bayes , DNA/metabolismo , Difusão , Cadeias de Markov , Método de Monte Carlo
6.
PLoS One ; 8(5): e64287, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23737978

RESUMO

Single-particle tracking (SPT) is widely used to study processes from membrane receptor organization to the dynamics of RNAs in living cells. While single-dye labeling strategies have the benefit of being minimally invasive, this comes at the expense of data quality; typically a data set of short trajectories is obtained and analyzed by means of the mean square displacements (MSD) or the distribution of the particles' displacements in a set time interval (jump distance, JD). To evaluate the applicability of both approaches, a quantitative comparison of both methods under typically encountered experimental conditions is necessary. Here we use Monte Carlo simulations to systematically compare the accuracy of diffusion coefficients (D-values) obtained for three cases: one population of diffusing species, two populations with different D-values, and a population switching between two D-values. For the first case we find that the MSD gives more or equally accurate results than the JD analysis (relative errors of D-values <6%). If two diffusing species are present or a particle undergoes a motion change, the JD analysis successfully distinguishes both species (relative error <5%). Finally we apply the JD analysis to investigate the motion of endogenous LPS receptors in live macrophages before and after treatment with methyl-ß-cyclodextrin and latrunculin B.


Assuntos
Membrana Celular/metabolismo , Corantes/metabolismo , Método de Monte Carlo , Algoritmos , Animais , Receptores de Lipopolissacarídeos/metabolismo , Lipopolissacarídeos/metabolismo , Camundongos , Técnicas de Sonda Molecular , Receptor 4 Toll-Like/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA