Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Endourol ; 37(8): 863-867, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37294208

RESUMO

Introduction: Recent retrospective literature suggests that the quick sequential organ failure assessment (qSOFA) scoring tool is a potentially superior tool over use of the systemic inflammatory response syndrome (SIRS) criteria to predict septic shock after percutaneous nephrolithotomy (PCNL) surgery. Here we examine use of qSOFA and SIRS to predict septic shock within data series collected prospectively on PCNL patients as part of a greater study of infectious complications. Materials and Methods: We performed a secondary analysis of two prospective multicenter studies including PCNL patients across nine institutions. Clinical signs informing SIRS and qSOFA scores were collected no later than postoperative day 1. The primary outcome was sensitivity and specificity of SIRS and qSOFA (high-risk score of greater-or-equal to two points) in predicting admission to the intensive care unit (ICU) for vasopressor support. Results: A total of 218 cases at 9 institutions were analyzed. One patient required vasopressor support in the ICU. The sensitivity/specificity was 100%/72.4% (McNemar's test p < 0.001) for SIRS and was 100%/90.8% (McNemar's test p < 0.001) for qSOFA. Conclusion: Although positive predictive value for both qSOFA and SIRS in prediction of post-PCNL septic shock is low, prospectively collected data demonstrate use of qSOFA may offer greater specificity than SIRS criteria when predicting post-PCNL septic shock.


Assuntos
Nefrolitotomia Percutânea , Sepse , Choque Séptico , Humanos , Choque Séptico/diagnóstico , Choque Séptico/etiologia , Escores de Disfunção Orgânica , Estudos Retrospectivos , Estudos Prospectivos , Prognóstico , Mortalidade Hospitalar , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Curva ROC
2.
Urologia ; 90(4): 670-677, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37154464

RESUMO

BACKGROUND: Isiris-α® is a single-use digital flexible cystoscope with an integrated grasper designed for double J (DJ) stent removal. Aim of this study was to conduct a multicentric evaluation of the costs and criticalities of stent removals performed with Isiris®-α in different hospitals and health systems, as compared to other DJ removal procedures. METHODS: After gathering 10 institutions worldwide with experience on Isiris-α®, we performed an analysis of the reported costs of DJ removal with Isiris-α®, as compared to the traditional reusable equipment used in each institution. The cost evaluation included instrument purchase, Endoscopic Room (EnR)/ Operatory Room (OR) occupancy, medical staff, instrument disposal, maintenance, repairs, decontamination or sterilization of reusable devices. RESULTS: The main factor affecting the costs of the procedure was OR/EnR occupancy. Decontamination and sterilization accounted for a less important part of total costs. Isiris-α® was more profitable in institutions where DJ removal is usually performed in the EnR/OR, allowing to transfer the procedure to outpatient clinic, with a significant cost saving and EnR/OR time saving to be allocated to other activities. In the only institution where DJ removal was already performed in outpatient clinics, there is a slight cost difference in favor of reusable instruments in high-volume institutions, given a sufficient number to guarantee the turnover. CONCLUSION: Isiris-α® leads to significant cost benefit in the institutions where DJ removal is routinely performed in EnR/OR, and brings significant improvement in organization, cost impact and turnover.


Assuntos
Cistoscópios , Ureter , Humanos , Custos Hospitalares , Cistoscopia/métodos , Remoção de Dispositivo , Ureter/cirurgia
3.
J Endourol ; 37(4): 467-473, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36458470

RESUMO

There is a call to improve Medicaid patient access to health care, enhance quality and outcomes of care, and reduce overall financial burden. We sought to build a comprehensive kidney stone program to help patients navigate through the acute and preventive aspects of stone disease by increasing multidisciplinary referrals and compliance with recommendations and decreasing no-show rates at first follow-up and repeat stone encounters after initial evaluation. A collaborative multidisciplinary program was established at our single institution consisting of urology, nephrology, and dietary specialists to be piloted over a 3-year period. Medicaid-designated patients were evaluated during new patient encounters by urology specialists and then followed for outpatient follow-up, including specialty referrals to nephrology specialists and dietitians, for targeted preventive measures. Subjective compliance reports by patients following interventions and no-show rates at subsequent follow-ups were documented. We also followed patients 6 months beyond the initial encounter to assess repeat Emergency Department (ED) visits for acute stone episodes. One hundred eighty-three Medicaid-designated stone patients were evaluated from 2018 to 2021. Sixty-eight percent of patients identified as White, 18% identified as Black/African American, and 14% identified as "Other." Patients underwent specialty referrals to nephrology or a dietician in 47% and 42% of cases, respectively. Since the program's implementation, reported patient compliance and referrals to multidisciplinary specialists increased from 72.9% to 81.30% and 21.2% to 56.20%, respectively. Repeat ED visits for stone-related encounters within 6 months of initial presentation remained relatively stable (from 17.60% to 18.9%), while no-show rates at first follow-up decreased from 20.0% to 6.30% by study conclusion. There is continued supporting evidence for the importance of a comprehensive kidney stone program specifically for patients of lower socioeconomic status following a 3-year implementation at our institution. Encouraging results indicate increased access to multidisciplinary specialty referrals, with improvement in follow-up and reported compliance related to stone prevention strategies.


Assuntos
Cálculos Renais , Medicina , Estados Unidos , Humanos , Cálculos Renais/terapia , Medicaid , Cooperação do Paciente , Qualidade da Assistência à Saúde
4.
Expert Rev Med Devices ; 17(12): 1257-1264, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33307869

RESUMO

Introduction: Flexible ureteroscopy is a commonly performed urologic procedure for visualization and treatment of the upper urinary tracts. Traditionally, ureteroscopy has been performed with reusable scopes, which have large initial purchasing costs. LithoVue was the first widely adopted single-use flexible ureteroscope clinically available in 2016 and has caused reevaluation of this paradigm. Areas covered: This review is an objective assessment of the LithoVue single-use ureteroscope based on available studies at the time of publication. The authors searched major databases for papers that included the term 'LithoVue' and included relevant papers. The state of the market, technical specifications, results from clinical studies and cost analyses, and competitors are discussed. Expert opinion: The LithoVue single-use flexible ureteroscope has comparable clinical performance to existing reusable ureteroscopes based on available data. Direct clinical comparisons to competing single-use ureteroscopes, many of which are relatively new, are limited. In numerous pre-clinical studies LithoVue performed favorably compared to available competitors. Cost analyses suggest that benefit of single-use ureteroscopes is institution-specific, and will likely be favorable at a low volume of cases and with high local costs for repairs of reusable scopes.


Assuntos
Cálculos Renais/cirurgia , Ureteroscópios/efeitos adversos , Aprovação de Equipamentos , Desenho de Equipamento , Humanos , Vigilância de Produtos Comercializados/economia , Resultado do Tratamento , Ureteroscópios/economia
5.
J Endourol ; 34(8): 816-820, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32600072

RESUMO

Background: A single-use flexible cystoscope with integrated grasper (Isiris; Coloplast, Denmark) has recently become commercially available. The objective of our study is to compare the costs of stent removal in an outpatient clinical environment between the single-use Isiris system (Coloplast) to our existing approach using a reusable cystoscope and stent grasper. Materials and Methods: The number of stent removal procedures at our tertiary center was recorded as a proportion of all cystoscopic procedures performed between February 2016 and February 2017. Elements in the micro-cost assessment included original purchasing price of an Olympus digital reusable cystoscope, repair fee (based on a 1-year contract), sterilization equipment and accessory costs, reprocessing costs of the cystoscope, and labor costs. The costs were estimated on a per-use basis and compared to the purchasing price of Isiris. Results: A total of 1775 cystoscopic procedures were performed, and the reusable cystoscope was used for stent removal in 871 (49%) cases. The per-use cost for stent removal procedures using the reusable cystoscope was estimated to be $161.85. The single per-use purchasing price for the Isiris device is $200. Based on the current volume, the break-even point was calculated to be 704 stent pulls. After 704 stent pulls, the cost benefit favors the reusable cystoscope. Conclusion: Based on this micro-cost analysis, per-use costs appear to favor the reusable cystoscope for stent removal. It appears that centers with high volumes of stent pulls may find the reusable cystoscope and stent grasper more cost beneficial than the single-use system.


Assuntos
Cistoscópios , Cistoscopia , Análise Custo-Benefício , Remoção de Dispositivo , Reutilização de Equipamento , Humanos , Stents
6.
J Urol ; 202(2): 314-318, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30829131

RESUMO

PURPOSE: Recent studies have demonstrated that quick sequential organ failure assessment criteria may be more accurate than systemic inflammatory response syndrome criteria to predict postoperative sepsis. In this study we evaluated the ability of these 2 criteria to predict septic shock after percutaneous nephrolithotomy. MATERIALS AND METHODS: We performed a retrospective multicenter study in 320 patients who underwent percutaneous nephrolithotomy at a total of 8 institutions. The criteria for quick sequential organ failure assessment and systemic inflammatory response syndrome were collected 24 hours postoperatively. The study primary outcome was postoperative septic shock. Secondary outcomes included 30 and 90-day emergency department visits, and the hospital readmission rate. RESULTS: Three of the 320 patients (0.9%) met the criteria for postoperative septic shock. These 3 patients had positive criteria for quick sequential organ failure assessment and systemic inflammatory response syndrome. Of the entire cohort 23 patients (7%) met quick sequential organ failure assessment criteria and 103 (32%) met systemic inflammatory response syndrome criteria. Specificity for postoperative sepsis was significantly higher for quick sequential organ failure assessment than for systemic inflammatory response syndrome (93.3% vs 68.4%, McNemar test p <0.001). The positive predictive value was 13% for quick sequential organ failure assessment criteria and 2.9% for systemic inflammatory response syndrome criteria. On multivariate logistic regression systemic inflammatory response syndrome criteria significantly predicted an increased probability of the patient receiving a transfusion (ß = 1.234, p <0.001). Positive quick sequential organ failure assessment criteria significantly predicted an increased probability of an emergency department visit within 30 days (ß = 1.495, p <0.05), operative complications (ß = 1.811, p <0.001) and transfusions (p <0.001). The main limitation of the study is that it was retrospective. CONCLUSIONS: Quick sequential organ failure assessment criteria were superior to systemic inflammatory response syndrome criteria to predict infectious complications after percutaneous nephrolithotomy.


Assuntos
Nefrolitotomia Percutânea , Escores de Disfunção Orgânica , Complicações Pós-Operatórias , Choque Séptico , Idoso , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Nefrolitotomia Percutânea/efeitos adversos , Admissão do Paciente , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Retrospectivos , Choque Séptico/etiologia , Síndrome de Resposta Inflamatória Sistêmica/etiologia
7.
Urol Pract ; 6(5): 294-299, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37317352

RESUMO

INTRODUCTION: We performed a decision analysis model of the cost-effectiveness of observation vs intervention for asymptomatic residual fragments less than 4 mm in diameter following ureteroscopic holmium laser lithotripsy. METHODS: Outcomes data from a retrospective analysis evaluating the natural history, complications and reintervention rates of asymptomatic residual stone fragments performed by the EDGE (Endourology Disease Group for Excellence) Research Consortium were used. A decision analysis model was constructed to compare the cost-effectiveness of initial observation of residual fragments to immediate intervention. Cost of observation included emergency room visits, hospitalizations and reinterventions. The cost analysis model extended to 3 years to account for delayed reintervention rates for fragments less than 4 mm. Costs of emergency department visits, readmissions and reinterventions were calculated based on published figures from the literature. RESULTS: Decision analysis modeling demonstrated that when comparing initial observation to immediate reintervention, the cost was $2,183 vs $4,424. The difference in cost was largely driven by the fact that over 3 years, approximately 55% of all patients remained asymptomatic and did not incur additional costs. This represents an approximate annual per patient savings of $747, and $2,241 over 3 years when observation is selected over immediate reintervention. CONCLUSIONS: Our decision analysis model demonstrates superior cost-effectiveness for observation over immediate reintervention for asymptomatic residual stones less than 4 mm following ureteroscopic lithotripsy. Based on these findings careful stratification and selection of patients may enable surgeons to improve cost-effectiveness of managing small, asymptomatic residual fragments following ureteroscopic lithotripsy.

9.
J Urol ; 195(6): 1859-65, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26778711

RESUMO

PURPOSE: The BLUS (Basic Laparoscopic Urologic Skills) consortium sought to address the construct validity of BLUS tasks and the wider problem of accurate, scalable and affordable skill evaluation by investigating the concordance of 2 novel candidate methods with faculty panel scores, those of automated motion metrics and crowdsourcing. MATERIALS AND METHODS: A faculty panel of surgeons (5) and anonymous crowdworkers blindly reviewed a randomized sequence of a representative sample of 24 videos (12 pegboard and 12 suturing) extracted from the BLUS validation study (454) using the GOALS (Global Objective Assessment of Laparoscopic Skills) survey tool with appended pass-fail anchors via the same web based user interface. Pre-recorded motion metrics (tool path length, jerk cost etc) were available for each video. Cronbach's alpha, Pearson's R and ROC with AUC statistics were used to evaluate concordance between continuous scores, and as pass-fail criteria among the 3 groups of faculty, crowds and motion metrics. RESULTS: Crowdworkers provided 1,840 ratings in approximately 48 hours, 60 times faster than the faculty panel. The inter-rater reliability of mean expert and crowd ratings was good (α=0.826). Crowd score derived pass-fail resulted in 96.9% AUC (95% CI 90.3-100; positive predictive value 100%, negative predictive value 89%). Motion metrics and crowd scores provided similar or nearly identical concordance with faculty panel ratings and pass-fail decisions. CONCLUSIONS: The concordance of crowdsourcing with faculty panels and speed of reviews is sufficiently high to merit its further investigation alongside automated motion metrics. The overall agreement among faculty, motion metrics and crowdworkers provides evidence in support of the construct validity for 2 of the 4 BLUS tasks.


Assuntos
Competência Clínica/estatística & dados numéricos , Crowdsourcing/estatística & dados numéricos , Laparoscopia/educação , Procedimentos Cirúrgicos Urológicos/educação , Área Sob a Curva , Humanos , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Gravação em Vídeo
10.
J Urol ; 194(4): 1098-105, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26025502

RESUMO

PURPOSE: We evaluated the internal and construct validity of an assessment tool for cystoscopic and ureteroscopic cognitive and psychomotor skills at a multi-institutional level. MATERIALS AND METHODS: Subjects included a total of 30 urology residents at Ohio State University, Columbus, Ohio; Penn Presbyterian Medical Center, Philadelphia, Pennsylvania; and Mayo Clinic, Rochester, Minnesota. A single external blinded reviewer evaluated cognitive and psychomotor skills associated with cystoscopic and ureteroscopic surgery using high fidelity bench models. Exercises included navigation, basketing and relocation; holmium laser lithotripsy; and cystoscope assembly. Each resident received a total cognitive score, checklist score and global psychomotor skills score. Construct validity was assessed by calculating correlations between training year and performance scores (both cognitive and psychomotor). Internal validity was confirmed by calculating correlations between test components. RESULTS: The median total cognitive score was 91 (IQR 86.25, 97). For psychomotor performance residents had a median total checklist score of 7 (IQR 5, 8) and a median global psychomotor skills score of 21 (IQR 18, 24.5). Construct validity was supported by the positive and statistically significant correlations between training year and total cognitive score (r = 0.66, 95% CI 0.39-0.82, p = 0.01), checklist scores (r = 0.66, 95% CI 0.35-0.84, p = 0.32) and global psychomotor skills score (r = 0.76, 95% CI 0.55-0.88, p = 0.002). The internal validity of OSATS was supported since total cognitive and checklist scores correlated with the global psychomotor skills score. CONCLUSIONS: In this multi-institutional study we successfully demonstrated the construct and internal validity of an objective assessment of cystoscopic and ureteroscopic cognitive and technical skills, including laser lithotripsy.


Assuntos
Lista de Checagem , Competência Clínica , Cistoscopia , Histeroscopia , Internato e Residência , Adulto , Feminino , Humanos , Masculino , Desempenho Psicomotor
11.
J Endourol ; 28(5): 582-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24341294

RESUMO

INTRODUCTION: Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. MATERIALS AND METHODS: Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-µm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. RESULTS: Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-value<0.01. The estimation of small stones (<4 mm) had a greater accuracy than large stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. CONCLUSIONS: This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.


Assuntos
Ureteroscópios , Urolitíase/patologia , Urologia , Adulto , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Valores de Referência , Ureteroscopia
12.
J Urol ; 185(1): 160-3, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21074810

RESUMO

PURPOSE: Single use and reusable variants of holmium:YAG laser fibers are available to treat calculi during ureteroscopic procedures. In this prospective, multicenter study we evaluated a series of reusable holmium:YAG laser optical fibers. We hypothesized that reusable fibers provide a cost advantage over single use variants. MATERIALS AND METHODS: We prospectively recorded fiber data, including type, size, number of uses, laser pulse energy and frequency, and total energy delivered. All fibers were new and purchased off the shelf by staff at each institution. We performed a cost analysis comparing reusable fibers to single use variants. RESULTS: During 541 procedures a total of 37 holmium:YAG optical laser fibers were used, including 21 Laser Peripherals 270 (Laser Peripherals, Golden Valley, Minnesota), 7 Laser Peripherals 365, 4 Lumenis SlimLine™ 200 and 3 Lumenis SlimLine 365 fibers. After stratifying by core size 365 µm core fibers had significantly more uses than 270 µm core fibers (average 23.5 vs 11.3, p < 0.02). By fiber type the mean ± SE number of uses was 12.8 ± 2.44, 3 ± 0.4, 21.3 ± 7.12 and 28.7 ± 6.69 for the Laser Peripheral 270, Lumenis SlimLine 200, Laser Peripherals 365 and Lumenis SlimLine 365, respectively. The total cost savings for reusable fibers vs single use variants was $64,125. CONCLUSIONS: Reusable holmium:YAG optical laser fibers are a more cost-effective option than single use variants. Fibers with a 365 µm core provide more uses than smaller 270 µm variants.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser/instrumentação , Fibras Ópticas , Análise Custo-Benefício , Reutilização de Equipamento/economia , Humanos , Litotripsia a Laser/economia , Fibras Ópticas/economia , Estudos Prospectivos , Cálculos Urinários/economia , Cálculos Urinários/terapia
13.
Urology ; 75(5): 1209-12, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20356618

RESUMO

OBJECTIVES: To evaluate the modalities of electrocautery, holmium:yttrium-aluminum-garnet (YAG) laser, hydrodissection, and combined holmium:YAG laser with hydrodissection applied to laparoscopic partial nephrectomy (LPN) in a porcine model. METHODS: A total of 16 Yorkshire pigs were divided into 4 equal groups (electrocautery, hydrodissection, holmium:YAG laser, and combined hydrodissection/holmium:YAG laser) and underwent unilateral LPN. The total operative time, partial nephrectomy time, hemostasis modality, and intraoperative complications were recorded. The pre- and postoperative hemoglobin was measured. Abdominal computed tomography was performed 2 weeks postoperatively. Representative specimens from each arm were examined for histologic findings. RESULTS: The mean total operative time and the time to perform partial nephrectomy was lower for the combined hydrodissection/holmium:YAG laser arm (66 minutes and 13 minutes, respectively) compared with the electrocautery arm (93 and 30 minutes, respectively), holmium:YAG laser-only arm (77 and 19 minutes, respectively), and hydrodissection-only arm (129 and 35 minutes, respectively). The mean decrease in hemoglobin was the least for the combined hydrodissection/holmium:YAG laser arm (5.3 g/L) followed by the holmium:YAG-only (15.3 g/L), hydrodissection-only (16.8 g/L), and electrocautery (35.5 g/L) arms, respectively. The histologic examination demonstrated an increased depth of tissue injury in the electrocautery arm. CONCLUSIONS: In a porcine model, the combined use of the hydrodissection/holmium:YAG laser to perform LPN had the shortest operative time and the lowest decrease in hemoglobin and appears to warrant additional clinical evaluation in human trials for LPN.


Assuntos
Laparoscopia , Terapia a Laser , Lasers de Estado Sólido/uso terapêutico , Nefrectomia/métodos , Animais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA