Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Surg ; 23(1): 179, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37370103

RESUMO

BACKGROUND: Liver-to-spleen signal intensity ratio (LSR) is evaluated by magnetic resonance imaging (MRI) in the hepatobiliary phase and has been reported as a useful radiological assessment of regional liver function. However, LSR is a passive (non-time-associated) assessment of liver function, not a dynamic (time-associated) assessment. Moreover, LSR shows limitations such as a dose bias of contrast medium and a timing bias of imaging. Previous studies have reported the advantages of time-associated liver functional assessment as a precise assessment of liver function. For instance, the indocyanine green (ICG) disappearance rate, which is calculated from serum ICG concentrations at multiple time points, reflects a precise preoperative liver function for predicting post-hepatectomy liver failure without the dose bias of ICG or the timing bias of blood sampling. The aim of this study was to develop a novel time-associated radiological liver functional assessment and verify its correlation with traditional liver functional parameters. METHODS: A total of 279 pancreatic cancer patients were evaluated to clarify fundamental time-associated changes to LSR in normal liver. We defined the time-associated radiological assessment of liver function, calculated using information on LSR from four time points, as the "LSR increasing rate" (LSRi). We then investigated correlations between LSRi and previous liver functional parameters. Furthermore, we evaluated how timing bias and protocol bias affect LSRi. RESULTS: Significant correlations were observed between LSRi and previous liver functional parameters such as total bilirubin, Child-Pugh grade, and albumin-bilirubin grade (P < 0.001 each). Moreover, considerably high correlations were observed between LSRi calculated using four time points and that calculated using three time points (r > 0.973 each), indicating that the timing bias of imaging was minimal. CONCLUSIONS: This study propose a novel time-associated radiological assessment, and revealed that the LSRi correlated significantly with traditional liver functional parameters. Changes in LSR over time may provide a superior preoperative assessment of regional liver function that is better for predicting post-hepatectomy liver failure than LSR using the hepatobiliary phase alone.


Assuntos
Falência Hepática , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Baço/diagnóstico por imagem , Baço/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Falência Hepática/patologia , Falência Hepática/cirurgia , Meios de Contraste , Hepatectomia , Neoplasias Hepáticas/cirurgia , Testes de Função Hepática , Verde de Indocianina , Bilirrubina , Espectroscopia de Ressonância Magnética , Gadolínio DTPA
2.
Am Surg ; 88(9): 2353-2360, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33856936

RESUMO

BACKGROUND: The liver-to-spleen signal intensity ratio (LSR) on magnetic resonance imaging with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid has been used as a parameter to assess liver function. LSR of the future remnant liver region (FR-LSR) is included in preoperative assessment of regional liver function. The aim of this study was to investigate the predictability of post-hepatectomy liver failure (PHLF) by FR-LSR. METHODS: Between May 2013 and May 2019, 127 patients underwent standardized EOB-MRI for diagnosis of liver tumor before major hepatectomy. The FR-LSR on EOB-MRI was calculated by a semiautomated three-dimensional volumetric analysis system. The cutoff value of FR-LSR in association with clinically relevant PHLF was determined according to the areas under the receiver operating characteristic curves. Then, FR-LSR and clinical variables were analyzed to assess the risk of clinically relevant PHLF. RESULTS: In patients with preoperative biliary drainage, metastatic liver tumor, estimated future remnant liver volume <50%, biliary reconstruction, operation time ≥ 480 min, estimated blood loss ≥ 1000 g, blood transfusion and a FR-LSR < 2.00 were associated with clinically relevant PHLF (P < .05 for all) in univariable analysis. The liver-to-spleen signal intensity ratio of the future remnant liver region < 2.00 was the only independent risk factor for clinically relevant PHLF in multivariable risk analysis (OR, 27.90; 95% CI: 7.99-136.40; P < .05). DISCUSSION: The present study revealed that FR-LSR calculated using a 3-dimensional volumetric analysis system was an independent risk factor for clinically relevant PHLF. The liver-to-spleen signal intensity ratio of the future remnant liver region might be a reliable preoperative parameter in liver functional assessment, enabling safe performance of major hepatectomy.


Assuntos
Insuficiência Hepática , Falência Hepática , Neoplasias Hepáticas , Gadolínio , Hepatectomia/efeitos adversos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Falência Hepática/etiologia , Falência Hepática/cirurgia , Testes de Função Hepática , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos
3.
J Comput Assist Tomogr ; 45(1): 84-92, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33475316

RESUMO

OBJECTIVE: This study aimed to assess the potential of an Ag additional filter attached to the bow tie filter of a computed tomography (CT) scanner to reduce the radiation dose in CT localizer radiography. METHODS: Radiation doses in CT localizer radiography with Cu and Ag additional filters were evaluated based on dose measurements and Monte Carlo simulations. Image quality evaluations of an adult torso phantom were performed, and the automatic exposure control performance was evaluated in terms of the water-equivalent thickness estimated from CT localizer radiographs. RESULTS: With the Ag additional filter, effective doses were approximately 72% to 75% lower than those with the Cu additional filter. The image quality and water-equivalent thickness with the Ag additional filter were similar to those with the Cu additional filter. CONCLUSIONS: The Ag additional filter helped significantly reduce radiation doses in CT localizer radiography while maintaining image quality and performance.


Assuntos
Prata/efeitos adversos , Tomografia Computadorizada por Raios X/instrumentação , Tronco/diagnóstico por imagem , Adulto , Cobre/efeitos adversos , Desenho de Equipamento , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
4.
Int J Endocrinol ; 2020: 5484671, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32256574

RESUMO

RESULTS: The 34 nodules comprised 14 benign nodules and 20 malignant nodules. Iodine content and Hounsfield unit curve slopes did not differ significantly between benign and malignant thyroid nodules (P = 0.480-0.670). However, significant differences in the texture features of monochromatic images were observed between benign and malignant nodules: histogram mean and median, co-occurrence matrix contrast, gray-level gradient matrix (GLGM) skewness, and mean gradients and variance of gradients for GLGM at 80 keV (P = 0.014-0.044). The highest AUC was 0.77, for the histogram mean and median of images acquired at 80 keV. CONCLUSIONS: Texture features extracted from monochromatic images using DECT, specifically acquired at high keV, may be a promising diagnostic approach for thyroid nodules. A further large study for incidental thyroid nodules using DECT texture analysis is required to validate our results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA