Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 119(3): 946-956, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300188

RESUMO

PURPOSE: A first of its kind experimental verification of dose-averaged linear energy transfer (LETd) optimized treatment plans for proton therapy has been carried out using a silicon-on-insulator microdosimeter at the Massachusetts General Hospital (MGH), Boston, USA. METHODS AND MATERIALS: Three clinical treatment plans of a typical ependymoma structure set were designed using the standard clinical approach, the proposed protocol approach, and a one-field approach. The plans were then reoptimized to reduce the LETd-weighted dose in the brain stem. All six plans were delivered in a solid water phantom and the experimental yD‾ measured. RESULTS: After LETd optimization, a reduction in yD‾ was found within the brain stem by an average of 12%, 19%, and 4% for the clinical, protocol, and one-field plans, respectively, while maintaining adequate coverage of the tumor structure. The experimental LETd-weighted doses were in agreement with the treatment planning system calculations and Monte Carlo simulations and reinforced the improvement of the optimization. CONCLUSIONS: This work demonstrates the first experimental verification of the clinical implementation of LETd optimization for patient treatment with proton therapy.


Assuntos
Neoplasias Encefálicas , Ependimoma , Transferência Linear de Energia , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Terapia com Prótons/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Ependimoma/radioterapia , Ependimoma/diagnóstico por imagem , Radiometria/métodos , Radiometria/instrumentação , Tronco Encefálico/diagnóstico por imagem , Silício , Órgãos em Risco/efeitos da radiação
2.
Med Phys ; 31(7): 2107-18, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15305464

RESUMO

Monte Carlo dosimetry calculations are essential methods in radiation therapy. To take full advantage of this tool, the beam delivery system has to be simulated in detail and the initial beam parameters have to be known accurately. The modeling of the beam delivery system itself opens various areas where Monte Carlo calculations prove extremely helpful, such as for design and commissioning of a therapy facility as well as for quality assurance verification. The gantry treatment nozzles at the Northeast Proton Therapy Center (NPTC) at Massachusetts General Hospital (MGH) were modeled in detail using the GEANT4.5.2 Monte Carlo code. For this purpose, various novel solutions for simulating irregular shaped objects in the beam path, like contoured scatterers, patient apertures or patient compensators, were found. The four-dimensional, in time and space, simulation of moving parts, such as the modulator wheel, was implemented. Further, the appropriate physics models and cross sections for proton therapy applications were defined. We present comparisons between measured data and simulations. These show that by modeling the treatment nozzle with millimeter accuracy, it is possible to reproduce measured dose distributions with an accuracy in range and modulation width, in the case of a spread-out Bragg peak (SOBP), of better than 1 mm. The excellent agreement demonstrates that the simulations can even be used to generate beam data for commissioning treatment planning systems. The Monte Carlo nozzle model was used to study mechanical optimization in terms of scattered radiation and secondary radiation in the design of the nozzles. We present simulations on the neutron background. Further, the Monte Carlo calculations supported commissioning efforts in understanding the sensitivity of beam characteristics and how these influence the dose delivered. We present the sensitivity of dose distributions in water with respect to various beam parameters and geometrical misalignments. This allows the definition of tolerances for quality assurance and the design of quality assurance procedures.


Assuntos
Algoritmos , Ciclotrons/instrumentação , Análise de Falha de Equipamento/métodos , Método de Monte Carlo , Terapia com Prótons , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Desenho de Equipamento , Modelos Estatísticos , Modelos Teóricos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Int J Radiat Oncol Biol Phys ; 37(1): 213-21, 1997 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-9054898

RESUMO

PURPOSE: In radiotherapy planning, the clinical target volume (CTV) is typically enlarged to create a planning target volume (PTV) that accounts for uncertainties due to internal organ and patient motion as well as setup error. Margin size clearly determines the volume of normal tissue irradiated, yet in practice it is often given a set value in accordance with a clinical precedent from which variations are rare. The (CTV/PTV) formalism does not account for critical structure dose. We present a numerical simulation to assess (CTV) coverage and critical organ dose as a function of treatment margins in the presence of organ motion and physical setup errors. An application of the model to the treatment of prostate cancer is presented, but the method is applicable to any site where normal tissue tolerance is a dose-limiting factor. METHODS AND MATERIALS: A Monte Carlo approach was used to simulate the cumulative effect of variation in overall tumor position, for individual treatment fractions, relative to a fixed distribution of dose. Distributions of potential dose-volume histograms (DVHs), for both tumor and normal tissues, are determined that fully quantify the stochastic nature of radiotherapy delivery. We introduce the concept of Probability of Prescription Dose (PoPD) isosurfaces as a tool for treatment plan optimization. Outcomes resulting from current treatment planning methods are compared with proposed techniques for treatment optimization. The standard planning technique of relatively large uniform margins applied to the CTV, in the beam's eye view (BEV), was compared with three other treatment strategies: (a) reduced uniform margins, (b) nonuniform margins adjusted to maximize normal tissue sparing, and (c) a reduced margin plan in which nonuniform fluence profiles were introduced to compensate for potential areas of reduced dose. RESULTS: Results based on 100 simulated full course treatments indicate that a 10 mm CTV to PTV margin, combined with an additional 5 mm dosimetric margin, provides adequate CTV coverage in the presence of known treatment uncertainties. Nonuniform margins can be employed to reduce dose delivered to normal tissues while preserving CTV coverage. Nonuniform fluence profiles can also be used to further reduce dose delivered to normal tissues, though this strategy does result in higher dose levels delivered to a small volume of the CTV and normal tissues. CONCLUSIONS: Monte Carlo-based treatment simulation is an effective means of assessing the impact of organ motion and daily setup error on dose delivery via external beam radiation therapy. Probability of Prescription Dose (PoPD) isosurfaces are a useful tool for the determination of nonuniform beam margins that reduce dose delivered to critical organs while preserving CTV dose coverage. Nonuniform fluence profiles can further alter critical organ dose with potential therapeutic benefits. Clinical consequences of this latter approach can only be assessed via clinical trials.


Assuntos
Algoritmos , Movimento , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador , Humanos , Masculino , Método de Monte Carlo , Neoplasias/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Reto , Tomografia Computadorizada por Raios X , Bexiga Urinária
4.
Med Phys ; 20(3): 755-60, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8350832

RESUMO

A sampling formalism is presented to accurately compute the absolute volumes and integral dose-volume histograms of small volumes treated in stereotactic radiosurgery. The presence of small volumes and sharp dose gradients places special constraints on the computational formalism and the accuracy required to compute the dose-volume relationships. We use a spatially nonuniform random sampling method to allow an efficient and accurate computation of the dose-volume histograms for an arbitrary number of volumes. The computation of absolute volume vs dose allows intercomparison of dose delivered to target and dose-critical volumes and allows a quantitative trade-off analysis often critical to an optimal treatment of the lesion.


Assuntos
Radiocirurgia/métodos , Algoritmos , Humanos , Modelos Estruturais , Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA