Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int J Cardiovasc Imaging ; 35(1): 23-32, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30062535

RESUMO

Echocardiographic assessment of left ventricular (LV) filling pressures is performed using a multi-parametric algorithm. Left atrial (LA) strain was recently found to accurately classify the degree of diastolic dysfunction. We hypothesized that LA strain could be used as a stand-alone marker and sought to identify and test a cutoff, which would accurately detect elevated LV pressures. We studied 76 patients with a spectrum of LV function who underwent same-day echocardiogram and invasive left-heart catheterization. Speckle tracking was used to measure peak LA strain. The protocol involved a retrospective derivation group (N = 26) and an independent prospective validation cohort (N = 50) to derive and then test a peak LA strain cutoff which would identify pre-A-wave LV diastolic pressure > 15 mmHg. The guidelines-based assessment of filling pressures and peak LA strain were compared side-by-side against invasive hemodynamic data. In the derivation cohort, receiver-operating characteristic analysis showed area under curve of 0.76 and a peak LA strain cutoff < 20% was identified as optimal to detect elevated filling pressure. In the validation cohort, peak LA strain demonstrated better agreement with the invasive reference (81%) than the guidelines algorithm (72%). The improvement in classification using LA strain compared to the guidelines was more pronounced in subjects with normal LV function (91% versus 81%). In summary, the use of a peak LA strain to estimate elevated LV filling pressures is more accurate than the current guidelines. Incorporation of LA strain into the non-invasive assessment of LV diastolic function may improve the detection of elevated filling pressures.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Doppler de Pulso , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Pressão Ventricular , Idoso , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia
2.
Echocardiography ; 35(10): 1606-1615, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30044511

RESUMO

Preservation of native left ventricular (LV) function in patients supported with LV assist device (LVAD) may be beneficial to attain optimal hemodynamics and enhance potential recovery. Currently, LVAD speed optimization is based on hemodynamic parameters, without considering residual native LV function. We hypothesized that alternatively, LV rotational mechanics can be quantified by 3D echocardiography (3DE), and may help preserve native LV function while optimizing LVAD speed. The goal of this study was to test the feasibility of quantifying the effects of LVAD implantation on LV rotational mechanics and to determine whether conventional speed optimization maximally preserves native LV function. We studied 55 patients with LVADs, who underwent 3DE imaging and quantitative analysis of LV twist. Thirty patients were studied before and after LVAD implantation. The remaining 25 patients were studied during hemodynamic ramp studies. The pump speed at which LV twist was maximal was compared with the hemodynamics-based optimal speed. LV twist decreased following LVAD implantation from 4.2 ± 2.7 to 2.3 ± 1.9° (P < 0.01), reflecting the constricting effects on native function. With lower pump speeds, no significant changes were noted in LV twist, which peaked at a higher speed. In 11/25 (44%) patients, the conventional hemodynamic/2DE methodology and 3DE assessment of maximal residual function did not indicate the same optimal conditions, suggesting that a higher pump speed would have better preserved native function. In conclusion, quantitative 3DE analysis of LV rotational mechanics provides information, which together with hemodynamics may help select optimal pump speed, while maximally preserving native LV function.


Assuntos
Ecocardiografia Tridimensional/métodos , Coração Auxiliar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Função Ventricular Esquerda
3.
J Am Soc Echocardiogr ; 31(1): 79-88, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29111121

RESUMO

BACKGROUND: Recent American Society of Echocardiography (ASE)/European Association of Cardiovascular Imaging (EACVI) guidelines for echocardiographic evaluation of left ventricular (LV) diastolic function provide a practical, simplified diagnostic algorithm for estimating LV filling pressure. The aim of this study was to test the accuracy of this algorithm against invasively measured pressures and compare it with the accuracy of the previous 2009 guidelines in the same patient cohort. METHODS: Ninety patients underwent transthoracic echocardiography immediately before left heart catheterization. Mitral inflow E/A ratio, E/e', tricuspid regurgitation velocity, and left atrial volume index were used to estimate LV filling pressure as normal or elevated using the ASE/EACVI algorithm. Invasive LV pre-A pressure was used as a reference, with >12 mm Hg defined as elevated. RESULTS: Invasive LV pre-A pressure was elevated in 40 (44%) and normal in 50 (56%) patients. The 2016 algorithm resulted in classification of 9 of 90 patients (10%) as indeterminate but estimated LV filling pressures in agreement with the invasive reference in 61 of 81 patients (75%), with sensitivity of 0.69 and specificity of 0.81. The 2009 algorithm could not definitively classify 4 of 90 patients (4.4%), but estimated LV filling pressures in agreement with the invasive reference in 64 of 86 patients (74%), with sensitivity of 0.79 and specificity of 0.70. CONCLUSIONS: The 2016 ASE/EACVI guidelines for estimation of filling pressures are more user friendly and efficient than the 2009 guidelines and provide accurate estimates of LV filling pressure in the majority of patients when compared with invasive measurements. The simplicity of the new algorithm did not compromise its accuracy and is likely to encourage its incorporation into clinical decision making.


Assuntos
Algoritmos , Ecocardiografia Doppler/métodos , Cardiopatias/diagnóstico , Guias de Prática Clínica como Assunto , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Diástole , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA