Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Neuroradiology ; 58(3): 237-44, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26631076

RESUMO

INTRODUCTION: Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. METHODS: We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. RESULTS: 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. CONCLUSION: 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.


Assuntos
Circulação Cerebrovascular , Transtornos Cerebrovasculares/fisiopatologia , Transtornos Cerebrovasculares/cirurgia , Angiografia por Ressonância Magnética/métodos , Artérias Temporais/transplante , Enxerto Vascular/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Sobrevivência de Enxerto , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Artéria Radial/transplante , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Grau de Desobstrução Vascular
2.
Radiology ; 250(3): 714-20, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19164114

RESUMO

PURPOSE: To assess the degree of renal necrosis and the leakage of absolute ethanol by using two methods: transcatheter renal artery embolization (TAE) and TAE performed with a closed renal circuit (CRC) (TAE/CRC), both performed by using ethanol and iodized oil, in a pig model. MATERIALS AND METHODS: All animal experiments were conducted in accordance with our university guidelines for animal care and experimentation. Fourteen pigs were classified in two groups: standard TAE and TAE/CRC groups. In the TAE/CRC group, the renal artery and vein were occluded with balloon catheters; in the TAE group, only the renal artery was occluded. An emulsion of absolute ethanol (0.5 mL per kilogram of body weight) and iodized oil (emulsion ratio, 4:1) was injected in the renal artery in both groups. In the TAE/CRC group, we aspirated the blood containing the emulsion via the renal vein during arterial infusion. We measured the ethanol concentrations of the systemic circulation. Four days after embolization, the kidneys in both groups were removed and histopathologic examination was performed and results were compared. RESULTS: The mean systemic ethanol concentration was less than 0.1 mg/mL in the TAE/CRC group and 0.28 mg/mL +/- 0.15 (standard deviation) in the TAE group (P < .002). In both groups, about 90% of the kidney was shown histopathologically to have undergone coagulation necrosis (no significant difference). The frequency of venous thrombus formation was significantly lower (P = .009) in the TAE/CRC group. CONCLUSION: TAE/CRC dramatically reduces ethanol leakage to the systemic circulation without a decrease in embolization effect in the normal swine kidney, and it also reduces the likelihood of venous thrombus formation.


Assuntos
Cateterismo/métodos , Embolização Terapêutica/métodos , Etanol/administração & dosagem , Etanol/farmacocinética , Rim/metabolismo , Rim/patologia , Artéria Renal/efeitos dos fármacos , Animais , Etanol/sangue , Suínos , Resultado do Tratamento
3.
Ann Nucl Med ; 19(5): 379-86, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16164194

RESUMO

UNLABELLED: The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. CONCLUSIONS: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.


Assuntos
Vasos Coronários/diagnóstico por imagem , Dobutamina , Ácidos Graxos/sangue , Imagem do Acúmulo Cardíaco de Comporta/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/metabolismo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/metabolismo , Eletrocardiografia , Teste de Esforço/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/complicações , Estatística como Assunto , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/etiologia
4.
Ann Nucl Med ; 17(6): 517-20, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14575391

RESUMO

PURPOSE: The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS: ERNV was performed from the best septal position (left anterior oblique view) in 20 patients with cardiac disease using a single detector anger-type gamma camera equipped with a low-energy, high-resolution collimator. Immediately thereafter, we performed a second ERNV using the solid-state gamma camera equipped with a highly sensitive collimator. Acquisition periods were 10 and 3 min, respectively. RESULTS: Significantly more counts were collected from over the left ventricle with the solid-state gamma camera over 3 min than those with the anger-type gamma camera over 10 min (817.1 +/- 387.8 k counts vs. 668.2 +/- 327.4 k counts, p < 0.01). The left ventricular ejection fraction obtained from ERNV data using the solid-state gamma camera correlated closely with those acquired by the anger-type gamma camera (r = 0.94, p < 0.0001, SEE = 5.93%). CONCLUSION: The results showed that the solid-state gamma camera could assess left ventricular function with excellent data collection efficiency and high reliability.


Assuntos
Análise de Falha de Equipamento , Câmaras gama , Cintilografia/instrumentação , Cintilografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Volume Sistólico , Transdutores , Disfunção Ventricular Esquerda/diagnóstico
5.
Ann Nucl Med ; 17(4): 289-95, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12932111

RESUMO

Through visual assessment by three-dimensional (3D) brain image analysis methods using stereotactic brain coordinates system, such as three-dimensional stereotactic surface projections and statistical parametric mapping, it is difficult to quantitatively assess anatomical information and the range of extent of an abnormal region. In this study, we devised a method to quantitatively assess local abnormal findings by segmenting a brain map according to anatomical structure. Through quantitative local abnormality assessment using this method, we studied the characteristics of distribution of reduced blood flow in cases with dementia of the Alzheimer type (DAT). Using twenty-five cases with DAT (mean age, 68.9 years old), all of whom were diagnosed as probable Alzheimer's disease based on NINCDS-ADRDA, we collected I-123 iodoamphetamine SPECT data. A 3D brain map using the 3D-SSP program was compared with the data of 20 cases in the control group, who age-matched the subject cases. To study local abnormalities on the 3D images, we divided the whole brain into 24 segments based on anatomical classification. We assessed the extent of an abnormal region in each segment (rate of the coordinates with a Z-value that exceeds the threshold value, in all coordinates within a segment), and severity (average Z-value of the coordinates with a Z-value that exceeds the threshold value). This method clarified orientation and expansion of reduced accumulation, through classifying stereotactic brain coordinates according to the anatomical structure. This method was considered useful for quantitatively grasping distribution abnormalities in the brain and changes in abnormality distribution.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Anatomia Transversal/métodos , Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Iofetamina , Fotogrametria/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Mapeamento Encefálico/métodos , Feminino , Humanos , Masculino , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Ann Nucl Med ; 16(5): 329-35, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12230092

RESUMO

UNLABELLED: The present study evaluates left ventricular performance during exercise by ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS: The study population consisted of 10 healthy volunteers (Group N) and 9 patients with ischemic heart disease (Group I). Seven patients in Group I had a history of prior myocardial infarction. Rest ECG-gated SPECT was performed 40 min after an injection of Tc-99m-tetrofosmin (555-740 MBq). After resting data acquisition, Group N underwent up to two 5-min stages of exercise (75 and 125 watts) on a detachable bicycle ergometer. The Group I patients all underwent symptom-limited, maximal testing on the ergometer. ECG-gated SPECT data were acquired from both groups for 3 min at rest and during the last 3 min of each exercise stage. RESULTS: Significant increases occurred in LVEF from rest to peak stress in both groups (from 55.4 +/- 5.8 to 66.6 +/- 4.1% in group N, p < 0.0001; from 49.0 +/- 12.8 to 56.7 +/- 13.8% in Group I, p < 0.001). The LVESV values significantly decreased to peak stress in Group N (from 49.9 +/- 13.1 to 37.8 +/- 10.0 ml, p < 0.0001), whereas LVEDV did not change (from 110.6 +/- 18.9 to 112.0 +/- 19.0 ml). In contrast, the LVESV values at rest and under peak stress were similar in Group I (from 52.6 +/- 23.9 to 51.7 +/- 31.4 ml) and LVEDV in Group I at peak exercise tended to increase (from 102.8 +/- 36.7 to 111.3 +/- 39.0 ml). The changes in LVESV from rest to peak stress were significantly different between Groups N and I (-12.1 +/- 6.3 vs. -0.9 +/- 11.6 ml, p < 0.02). CONCLUSION: ECG-gated SPECT with short-time data collection can assess left ventricular function during exercise and may offer useful information for evaluating patients with ischemic heart disease.


Assuntos
Teste de Esforço/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Isquemia Miocárdica/complicações , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Descanso , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
7.
Ann Nucl Med ; 16(4): 237-42, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12126092

RESUMO

BACKGROUND: In contrast to 201TlCl, 99mTc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of 99mTc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. METHODS AND RESULTS: After administration of 99mTc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec(-1)), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6+/-5.2%) were significantly higher than those in the NC group (31.2+/-5.5%, p < 0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r = -0.61, p < 0.001), PFR (r = -0.47, p < 0.01), LVEDV (r = 0.45, p < 0.01) and LVESV (r = 0.48, p < 0.01). CONCLUSION: The myocardial washout rate of 99Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/metabolismo , Miocárdio/metabolismo , Volume Sistólico , Tecnécio Tc 99m Sestamibi/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/metabolismo , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único , Ventriculografia de Primeira Passagem
8.
Kaku Igaku ; 39(4): 469-76, 2002 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-12607234

RESUMO

UNLABELLED: Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS: Thirty-five patients with cardiac disease were enrolled. Following intravenous bolus injection of 740 MBq of 99mTc human serum albumin-DTPA, first-pass radionuclide angiography (FP) and 25-gated interval planar multi-gated blood pool scintigraphy (PMUGA) were performed for the measurement of right ventricular ejection fraction (RVEF; %) and left ventricular ejection fraction (LVEF; %), respectively. Subsequently TMUGA data set was acquired with a dual-head gamma camera (16 gated intervals). Then, alternative LVEF and RVEF were measured using TMUGA with QBS. Regional left ventricular wall motion for both PMUGA and TMUGA were assessed with a 4-point scoring system respectively. RESULTS: Automatic biventricular border detection using QBS was feasible in 27 of 35 patients (70.7%). Measurements of TMUGA LVEF and RVEF were well reproducible, with interobserver correlation coefficient of 0.98 and 0.97, respectively. TMUGA LVEF showed excellent correlation with PMUGA LVEF (r = 0.98, SEE = 3.92%). The agreement of LV wall motion score between TMUGA and PMUGA was 88.1% (214 of 243 segments), with a kappa value of 0.82. On the other hand, RVEF determined by QBS had a 12.4% average overestimate compared to the same value obtained by FP. Moreover 95% confidential interval of TMUGA RVEF (-28.8 to +4.0%) was wider than that of TMUGA LVEF (-10.7 to +10.7%). CONCLUSION: TMUGA with QBS analysis provided accurate and reproducible data for global and regional left ventricular function. However, the results of RVEF with TMUGA were not satisfying as a replacement for those with FP and modifying the algorithm were needed to improve accuracy of quantification.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Feminino , Coração/fisiopatologia , Cardiopatias/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Agregado de Albumina Marcado com Tecnécio Tc 99m , Pentetato de Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA