Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Open Heart ; 11(1)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238026

RESUMO

INTRODUCTION: Three recent randomised controlled trials have demonstrated that pulmonary vein isolation as an initial rhythm control strategy with cryoablation reduces atrial arrhythmia recurrence in patients with symptomatic paroxysmal atrial fibrillation (PAF) compared with antiarrhythmic drug (AAD) therapy. The aim of this study was to evaluate the cost-effectiveness of first-line cryoablation compared with first-line AADs for treating symptomatic PAF in an English National Health Service (NHS) setting. METHODS: Individual patient-level data from 703 participants with PAF enrolled into Cryo-FIRST (Catheter Cryoablation Versus Antiarrhythmic Drug as First-Line Therapy of Paroxysmal Atrial Fibrillation), STOP AF First (Cryoballoon Catheter Ablation in an Antiarrhythmic Drug Naive Paroxysmal Atrial Fibrillation) and EARLY-AF (Early Aggressive Invasive Intervention for Atrial Fibrillation) were used to derive the parameters applied in the cost-effectiveness model (CEM). The CEM comprised a hybrid decision tree and Markov structure. The decision tree had a 1-year time horizon and was used to inform the initial health state allocation in the first cycle of the Markov model (40-year time horizon; 3-month cycle length). Health benefits were expressed in quality-adjusted life years (QALYs). Costs and benefits were discounted at 3.5% per year. Model outcomes were generated using probabilistic sensitivity analysis. RESULTS: The results estimated that cryoablation would yield more QALYs (+0.17) and higher costs (+£641) per patient over a lifetime than AADs. This produced an incremental cost-effectiveness ratio of £3783 per QALY gained. Independent of initial treatment, individuals were expected to receive ~1.2 ablations over a lifetime. There was a 45% relative reduction in time spent in AF health states for those initially treated with cryoablation. DISCUSSION: AF rhythm control with first-line cryoablation is cost effective compared with first-line AADs in an English NHS setting.


Assuntos
Fibrilação Atrial , Criocirurgia , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Medicina Estatal , Antiarrítmicos/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos
2.
Can J Cardiol ; 40(4): 576-584, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38007219

RESUMO

BACKGROUND: The EARLY-AF (NCT02825979), STOP AF First (NCT03118518), and Cryo-FIRST (NCT01803438) randomised controlled trials (RCTs) demonstrated that cryoballoon pulmonary vein isolation reduces atrial fibrillation (AF) recurrence compared with antiarrhythmic drugs (AADs) in patients with symptomatic paroxysmal atrial fibrillation (PAF). The present study developed a cost-effectiveness model (CEM) of first-line cryoablation compared with first-line AADs for PAF, from the Canadian health care payer's perspective. METHODS: Data from the 3 RCTs were analysed to estimate key CEM parameters. The model structure used a decision tree for the first 12 months and a Markov model with a 3-month cycle length for the remaining lifetime time horizon. Costs were set at 2023 Canadian dollars, health benefits were expressed as quality-adjusted life years (QALYs), and both were discounted 3% annually. Probabilistic sensitivity analysis (PSA) considered parameter uncertainty. RESULTS: The statistical analysis estimated that first-line cryoablation generates a 47% reduction (P < 0.001) in the rate of AF recurrence, a 73% reduction in the rate of subsequent ablation (P < 0.001), and a 4.3% (P = 0.025) increase in health-related quality of life, compared with first-line AADs. The PSA indicates that an individual treated with first-line cryoablation accrues less costs (-$3,862) and more QALYs (0.19) compared with first-line AADs. Cryoablation is cost-saving in 98.4% of PSA iterations and has a 99.9% probability of being cost-effective at a cost-effectiveness threshold of $50,000 per QALY gained. Cost-effectiveness results were robust to changes in key model parameters. CONCLUSIONS: First-line cryoballoon ablation is cost-effective when compared with AADs for patients with symptomatic PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Canadá/epidemiologia , Resultado do Tratamento , Recidiva
3.
Heart Rhythm O2 ; 4(9): 528-537, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37744940

RESUMO

Background: Three recent randomized controlled trials have demonstrated that, as an initial rhythm control strategy, first-line cryoballoon ablation (cryoablation) reduces atrial arrhythmia recurrence compared with antiarrhythmic drugs (AADs) in patients with symptomatic paroxysmal atrial fibrillation (PAF). Objective: The study sought to evaluate the cost-effectiveness of first-line cryoablation compared with first-line AADs for treating symptomatic PAF from a U.S. Medicare payer perspective. Methods: Individual patient-level data from 703 participants with PAF enrolled into the Cryo-FIRST (NCT01803438), STOP AF First (NCT03118518), and EARLY-AF (NCT02825979) trials were used to derive parameters for the cost-effectiveness model. The cost-effectiveness model used a hybrid decision tree and Markov structure. The decision tree had a 1-year time horizon and was used to inform the initial health state allocation in the first cycle of the Markov model. The Markov model used a 40-year time horizon (3-month cycle length). Health benefits were expressed in quality-adjusted life years (QALYs). Costs and benefits were discounted at 3% per year. Results: Cryoablation was estimated to yield higher QALYs (+0.17) and higher costs (+$4274) per patient over a 40-year time horizon than AADs. Ultimately, this produced an average incremental cost-effectiveness ratio of $24,637 per QALY gained. Independent of initial treatment, individuals were expected to receive ∼1.2 ablations over a lifetime. There was a 45% relative reduction in time spent in atrial fibrillation health states for those initially treated with cryoablation compared with AADs. Conclusion: Initial rhythm control with first-line cryoballoon ablation is highly cost-effective compared with first-line AADs from a U.S. Medicare payer perspective.

4.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37062040

RESUMO

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Incidência , Fatores de Risco , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Fístula Esofágica/diagnóstico , Prognóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA