Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Diabetologia ; 32(11): 774-8, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2591646

RESUMO

Nine selected sera were studied using radioimmunoassay and enzyme linked immunosorbent assay; eight contained insulin antibodies and were from Type 1 (insulin-dependent) diabetic patients, one of whom had antibody-mediated insulin resistance, and one contained insulin-autoantibodies and was from an asymptomatic blood donor. Sera were assayed in serial dilution to assess their suitability for use as reference standards. Dilution curves were non-parallel in radioimmunoassay but were parallel in immunosorbent assay. In all sera, insulin antibodies were readily detected in both assays whereas the low avidity insulin autoantibodies were only detected by immunosorbent assay and not at all by radioimmunoassay, suggesting that the assays respond differently to antibodies of different avidity. Avidity was estimated in liquid phase from the dissociation rate of preformed complexes of antibody and 125-iodinated insulin. When high avidity antibodies are used as a reference in radioimmunoassay, lower avidity antibodies are underestimated and vice versa. In contrast, in immunosorbent assay, any serum could be used as a reference regardless of avidity; furthermore competition experiments comparing the highest avidity insulin antibodies, from the insulin-resistant patient, with the insulin autoantibodies from the asymptomatic blood donor yielded near-superimposable curves. We conclude that radioimmunoassay is selective for high avidity antibodies whereas enzyme linked immunosorbent assay is not; computer modelling of the two assays supports this conclusion. In practice immunosorbent assay can be standardized using a reference serum, whereas experimental findings and mathematical considerations preclude the use of a standard serum in radioimmunoassay.


Assuntos
Autoanticorpos/análise , Diabetes Mellitus Tipo 1/imunologia , Anticorpos Anti-Insulina/análise , Animais , Complexo Antígeno-Anticorpo/análise , Reações Antígeno-Anticorpo , Ligação Competitiva , Bovinos , Ensaio de Imunoadsorção Enzimática , Humanos , Resistência à Insulina , Cinética , Radioimunoensaio/métodos , Valores de Referência
2.
Radiology ; 155(2): 333-4, 1985 May.
Artigo em Inglês | MEDLINE | ID: mdl-3983382

RESUMO

Although percutaneous aspiration and drainage of abdominal abscesses will frequently avert an open surgical procedure, patients remain hospitalized during drainage. The authors treated 9 patients for abscesses using percutaneous drainage catheters and sent them home with the catheter in place. All had an uneventful recovery. An average of $12,050 was saved in each case. The authors suggest that outpatient drainage of abdominal abscesses is significantly less expensive than inpatient treatment, yet does not jeopardize patient care.


Assuntos
Abdome , Abscesso/terapia , Assistência Ambulatorial , Drenagem , Adulto , Idoso , Assistência Ambulatorial/economia , Custos e Análise de Custo , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA