Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
NMR Biomed ; 37(6): e5116, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38359842

RESUMO

Accurately measuring renal function is crucial for pediatric patients with kidney conditions. Traditional methods have limitations, but dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) provides a safe and efficient approach for detailed anatomical evaluation and renal function assessment. However, motion artifacts during DCE-MRI can degrade image quality and introduce misalignments, leading to unreliable results. This study introduces a motion-compensated reconstruction technique for DCE-MRI data acquired using golden-angle radial sampling. Our proposed method achieves three key objectives: (1) identifying and removing corrupted data (outliers) using a Gaussian process model fitting with a k -space center navigator, (2) efficiently clustering the data into motion phases and performing interphase registration, and (3) utilizing a novel formulation of motion-compensated radial reconstruction. We applied the proposed motion correction (MoCo) method to DCE-MRI data affected by varying degrees of motion, including both respiratory and bulk motion. We compared the outcomes with those obtained from the conventional radial reconstruction. Our evaluation encompassed assessing the quality of images, concentration curves, and tracer kinetic model fitting, and estimating renal function. The proposed MoCo reconstruction improved the temporal signal-to-noise ratio for all subjects, with a 21.8% increase on average, while total variation values of the aorta, right, and left kidney concentration were improved for each subject, with 32.5%, 41.3%, and 42.9% increases on average, respectively. Furthermore, evaluation of tracer kinetic model fitting indicated that the median standard deviation of the estimated filtration rate ( σ F T ), mean normalized root-mean-squared error (nRMSE), and chi-square goodness-of-fit of tracer kinetic model fit were decreased from 0.10 to 0.04, 0.27 to 0.24, and, 0.43 to 0.27, respectively. The proposed MoCo technique enabled more reliable renal function assessment and improved image quality for detailed anatomical evaluation in the case of bulk and respiratory motion during the acquisition of DCE-MRI.


Assuntos
Meios de Contraste , Rim , Imageamento por Ressonância Magnética , Movimento (Física) , Humanos , Imageamento por Ressonância Magnética/métodos , Meios de Contraste/química , Rim/diagnóstico por imagem , Rim/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Testes de Função Renal/métodos , Masculino , Feminino , Artefatos , Razão Sinal-Ruído
2.
ArXiv ; 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38313196

RESUMO

Quantitative analysis of pseudo-diffusion in diffusion-weighted magnetic resonance imaging (DWI) data shows potential for assessing fetal lung maturation and generating valuable imaging biomarkers. Yet, the clinical utility of DWI data is hindered by unavoidable fetal motion during acquisition. We present IVIM-morph, a self-supervised deep neural network model for motion-corrected quantitative analysis of DWI data using the Intra-voxel Incoherent Motion (IVIM) model. IVIM-morph combines two sub-networks, a registration sub-network, and an IVIM model fitting sub-network, enabling simultaneous estimation of IVIM model parameters and motion. To promote physically plausible image registration, we introduce a biophysically informed loss function that effectively balances registration and model-fitting quality. We validated the efficacy of IVIM-morph by establishing a correlation between the predicted IVIM model parameters of the lung and gestational age (GA) using fetal DWI data of 39 subjects. Our approach was compared against six baseline methods: 1) no motion compensation, 2) affine registration of all DWI images to the initial image, 3) deformable registration of all DWI images to the initial image, 4) deformable registration of each DWI image to its preceding image in the sequence, 5) iterative deformable motion compensation combined with IVIM model parameter estimation, and 6) self-supervised deep-learning-based deformable registration. IVIM-morph exhibited a notably improved correlation with gestational age (GA) when performing in-vivo quantitative analysis of fetal lung DWI data during the canalicular phase. Specifically, over 2 test groups of cases, it achieved an Rf2 of 0.44 and 0.52, outperforming the values of 0.27 and 0.25, 0.25 and 0.00, 0.00 and 0.00, 0.38 and 0.00, and 0.07 and 0.14 obtained by other methods. IVIM-morph shows potential in developing valuable biomarkers for non-invasive assessment of fetal lung maturity with DWI data. Moreover, its adaptability opens the door to potential applications in other clinical contexts where motion compensation is essential for quantitative DWI analysis. The IVIM-morph code is readily available at:https://github.com/TechnionComputationalMRILab/qDWI-Morph.

3.
Med Image Anal ; 67: 101880, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147561

RESUMO

Early identification of kidney function deterioration is essential to determine which newborn patients with congenital kidney disease should be considered for surgical intervention as opposed to observation. Kidney function can be measured by fitting a tracer kinetic (TK) model onto a series of Dynamic Contrast Enhanced (DCE) MR images and estimating the filtration rate parameter from the model. Unfortunately, breathing and large bulk motion events due to patient movement in the scanner create outliers and misalignments that introduce large errors in the TK model parameter estimates even when using a motion-robust dynamic radial VIBE sequence for DCE-MR imaging. The misalignments between the series of volumes are difficult to correct using standard registration due to 1) the large differences in geometry and contrast between volumes of the dynamic sequence and 2) the requirement of fast dynamic imaging to achieve high temporal resolution and motion deteriorates image quality. These difficulties reduce the accuracy and stability of registration over the dynamic sequence. An alternative registration approach is to generate noise and motion free templates of the original data from the TK model and use them to register each volume to its contrast-matched template. However, the TK models used to characterize DCE-MRI are tissue specific, non-linear and sensitive to the same motion and sampling artifacts that hinder registration in the first place. Hence, these can only be applied to register accurately pre-segmented regions of interest, such as kidneys, and might converge to local minima under the presence of large artifacts. Here we introduce a novel linear time invariant (LTI) model to characterize DCE-MR data for different tissue types within a volume. We approximate the LTI model as a sparse sum of first order LTI functions to introduce robustness to motion and sampling artifacts. Hence, this model is well suited for registration of the entire field of view of DCE-MR data with artifacts and outliers. We incorporate this LTI model into a registration framework and evaluate it on both synthetic data and data from 20 children. For each subject, we reconstructed the sequence of DCE-MR images, detected corrupted volumes acquired during motion, aligned the sequence of volumes and recovered the corrupted volumes using the LTI model. The results show that our approach correctly aligned the volumes, provided the most stable registration in time and improved the tracer kinetic model fit.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Artefatos , Criança , Humanos , Recém-Nascido , Rim/diagnóstico por imagem , Movimento (Física)
4.
J Magn Reson Imaging ; 49(6): 1565-1576, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30353957

RESUMO

BACKGROUND: Contrast-enhanced MRI of the small bowel is an effective imaging sequence for the detection and characterization of disease burden in pediatric Crohn's disease (CD). However, visualization and quantification of disease burden requires scrolling back and forth through 3D images to follow the anatomy of the bowel, and it can be difficult to fully appreciate the extent of disease. PURPOSE: To develop and evaluate a method that offers better visualization and quantitative assessment of CD from MRI. STUDY TYPE: Retrospective. POPULATION: Twenty-three pediatric patients with CD. FIELD STRENGTH/SEQUENCE: 1.5T MRI system and T1 -weighted postcontrast VIBE sequence. ASSESSMENT: The convolutional neural network (CNN) segmentation of the bowel's lumen, wall, and background was compared with manual boundary delineation. We assessed the reproducibility and the capability of the extracted markers to differentiate between different levels of disease defined after a consensus review by two experienced radiologists. STATISTICAL TESTS: The segmentation algorithm was assessed using the Dice similarity coefficient (DSC) and boundary distances between the CNN and manual boundary delineations. The capability of the extracted markers to differentiate between different disease levels was determined using a t-test. The reproducibility of the extracted markers was assessed using the mean relative difference (MRD), Pearson correlation, and Bland-Altman analysis. RESULTS: Our CNN exhibited DSCs of 75 ± 18%, 81 ± 8%, and 97 ± 2% for the lumen, wall, and background, respectively. The extracted markers of wall thickness at the location of min radius (P = 0.0013) and the median value of relative contrast enhancement (P = 0.0033) could differentiate active and nonactive disease segments. Other extracted markers could differentiate between segments with strictures and segments without strictures (P < 0.05). The observers' agreement in measuring stricture length was >3 times superior when computed on curved planar reformatting images compared with the conventional scheme. DATA CONCLUSION: The results of this study show that the newly developed method is efficient for visualization and assessment of CD. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1565-1576.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Algoritmos , Criança , Bases de Dados Factuais , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Redes Neurais de Computação , Variações Dependentes do Observador , Probabilidade , Radiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
5.
Med Image Anal ; 32: 173-83, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27111049

RESUMO

Quantitative diffusion-weighted MR imaging (DW-MRI) of the body enables characterization of the tissue microenvironment by measuring variations in the mobility of water molecules. The diffusion signal decay model parameters are increasingly used to evaluate various diseases of abdominal organs such as the liver and spleen. However, previous signal decay models (i.e., mono-exponential, bi-exponential intra-voxel incoherent motion (IVIM) and stretched exponential models) only provide insight into the average of the distribution of the signal decay rather than explicitly describe the entire range of diffusion scales. In this work, we propose a probability distribution model of incoherent motion that uses a mixture of Gamma distributions to fully characterize the multi-scale nature of diffusion within a voxel. Further, we improve the robustness of the distribution parameter estimates by integrating spatial homogeneity prior into the probability distribution model of incoherent motion (SPIM) and by using the fusion bootstrap solver (FBM) to estimate the model parameters. We evaluated the improvement in quantitative DW-MRI analysis achieved with the SPIM model in terms of accuracy, precision and reproducibility of parameter estimation in both simulated data and in 68 abdominal in-vivo DW-MRIs. Our results show that the SPIM model not only substantially reduced parameter estimation errors by up to 26%; it also significantly improved the robustness of the parameter estimates (paired Student's t-test, p < 0.0001) by reducing the coefficient of variation (CV) of estimated parameters compared to those produced by previous models. In addition, the SPIM model improves the parameter estimates reproducibility for both intra- (up to 47%) and inter-session (up to 30%) estimates compared to those generated by previous models. Thus, the SPIM model has the potential to improve accuracy, precision and robustness of quantitative abdominal DW-MRI analysis for clinical applications.


Assuntos
Abdome/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Movimento , Adolescente , Algoritmos , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Masculino , Cadeias de Markov , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Baço/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA