Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Cardiovasc Imaging ; 37(1): 37-45, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32779079

RESUMO

Although optical coherence tomography (OCT) proved to be able to identify macrophage clusters, there are no available data on the possibility to obtain reproducible measurements of their circumferential extension and location. The purpose of the present post-hoc analysis of the CLIMA study was to revise the clinical and demographic variables of patients having coronary plaques with macrophages and to investigate the reproducibility of their quantitative assessment. A total of 577 patients out of 1003 undergoing OCT showed macrophage accumulation. Three groups were identified; group 1 (426 patients) without macrophages, group 2 (296) patients with low macrophage content (less than median value [67°] of circumferential arc) and group 3 (281) with high macrophage content arc [> 67°]. Patients with macrophages (groups 2 and 3) showed a higher prevalence of family history for coronary artery disease and hypercholesterolemia and had a significantly larger body mass index. Furthermore, group 3 had more commonly triple vessel disease and higher value of LDL cholesterol levels compared to the two other groups. The inter-observer agreement for macrophage interpretation was good: R values were 0.97 for the circumferential arc extension, 0.95 for the minimum distance and 0.98 for the mean distance. A non-significant correlation between circumferential extension of macrophages and hsCRP values was found (R = 0.013). Quantitative assessment of macrophage accumulations can be obtained with high reproducibility by OCT. The presence and amount of macrophages are poorly correlated with hsCRP and identify patients with more advanced atherosclerosis and higher LDL cholesterol levels.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Macrófagos/patologia , Placa Aterosclerótica , Tomografia de Coerência Óptica , Idoso , Biomarcadores/sangue , Proteína C-Reativa/análise , LDL-Colesterol/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros
2.
G Ital Cardiol (Rome) ; 20(9 Suppl 1): 44S-49S, 2019 09.
Artigo em Italiano | MEDLINE | ID: mdl-31593190

RESUMO

Despite improvements in the treatment and prevention of risk factors (i.e. dyslipidemia), cardiovascular disease (CVD) remains one of the leading causes of morbidity and mortality in countries with a high degree of socio-economic development. As a matter of fact, in the last decades, several trials and meta-analysis highlighted the impact of treatments targeted to lowering cholesterol levels (particularly LDL-cholesterol) on outcomes of patients affected by CVD, both in terms of primary and secondary prevention. The main international CVD guidelines recommend lifestyle modifications and optimal lipid-lowering therapy in individuals with established CVD. The aim of the present document is to describe the dimension of the problem and the available therapies, offering a practical pharmacological flow-chart useful for accurate monitoring and intensive treatment of dyslipidemias in this patient population.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Dislipidemias/terapia , Prevenção Secundária , Doenças Cardiovasculares/etiologia , Árvores de Decisões , Dislipidemias/complicações , Humanos , Guias de Prática Clínica como Assunto
3.
EuroIntervention ; 15(9): e804-e811, 2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31217142

RESUMO

AIMS: The aim of this study was to describe the epidemiology, mechanisms, management, and outcomes of coronary artery perforation during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS AND RESULTS: We included 1,811 consecutive patients undergoing CTO PCI at five centres between 2011 and 2018. Coronary perforation was observed in n=99 (5.5%). Patients with perforation were older, had a higher J-CTO score, more often required antegrade dissection/re-entry and the retrograde approach, and had lower success rates. The frequency of Ellis type I, II, III and III "cavity spilling" perforations was 11%, 46%, 28%, and 14%, respectively. In 48% of cases, perforation involved the CTO vessel, while the retrograde approach was responsible for 46% of cases. In 53% of cases perforations required intervention. The most frequently applied management strategies included clinical observation (47%), covered stent implantation (25%), balloon occlusion (9%), and coil/fat embolisation (9%). Tamponade was observed in 20/99 (20%) perforation cases. Ellis type III perforations were most frequently observed at the CTO site. These were accountable for 16/20 tamponades and 3/5 deaths. In-hospital mortality was 5.1% vs 0.3% in patients with versus those without perforation (p<0.001). Older age, occlusion length >20 mm, rotational atherectomy, antegrade dissection/re-entry, and the retrograde approach were independently associated with coronary perforation. Patients with perforation suffered an increased incidence of target vessel failure on short-term follow-up. CONCLUSIONS: Coronary perforation is observed in a non-negligible proportion of CTO PCIs, often requires intervention, and is associated with tamponade and mortality in a minority of patients. CTO vessel-related perforations are associated with the highest burden of morbidity and mortality.


Assuntos
Oclusão Coronária/cirurgia , Vasos Coronários/lesões , Intervenção Coronária Percutânea/efeitos adversos , Lesões do Sistema Vascular/epidemiologia , Idoso , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Complicações Intraoperatórias/epidemiologia , Masculino , Intervenção Coronária Percutânea/métodos , Derrame Pericárdico , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico
5.
G Ital Cardiol (Rome) ; 18(2 Suppl 1): 3S-8S, 2017 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-28398395

RESUMO

Mitral regurgitation is the most common valvular heart disease in western world, with moderate to severe mitral regurgitation having a deep impact on prognosis, mortality and rehospitalizations. Advanced congestive heart failure is frequently complicated by mitral regurgitation, a pathologic condition that is often under-diagnosed. A significant proportion of patients with severe mitral regurgitation is not eligible for surgery (mitral valve repair or replacement) because of contraindications or excessive surgical risk. Therefore, the need for a less invasive treatment has led to the development of endovascular techniques; among them the MitraClip system, which mimics Alfieri's edge-to-edge surgical technique introduced in 2003, has gained widespread acceptance. More than 35 000 patients have been treated using this technique. Evidence from clinical studies suggests that the MitraClip system is effective in improving survival and quality of life in patients with severe mitral regurgitation, also reducing rehospitalization rates with substantial social and economic advantages. At present, in Italy, undertreatment of patients with severe mitral regurgitation not amenable to surgical correction is still significantly high, and remarkable inhomogeneity among regions is observed in the availability of the MitraClip procedure.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Acessibilidade aos Serviços de Saúde , Implante de Prótese de Valva Cardíaca/economia , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia
6.
J Cardiovasc Magn Reson ; 13: 82, 2011 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-22202669

RESUMO

BACKGROUND: Before trans-catheter aortic valve implantation (TAVI), assessment of cardiac function and accurate measurement of the aortic root are key to determine the correct size and type of the prosthesis. The aim of this study was to compare cardiovascular magnetic resonance (CMR) and trans-thoracic echocardiography (TTE) for the assessment of aortic valve measurements and left ventricular function in high-risk elderly patients submitted to TAVI. METHODS: Consecutive patients with severe aortic stenosis and contraindications for surgical aortic valve replacement were screened from April 2009 to January 2011 and imaged with TTE and CMR. RESULTS: Patients who underwent both TTE and CMR (n = 49) had a mean age of 80.8 ± 4.8 years and a mean logistic EuroSCORE of 14.9 ± 9.3%. There was a good correlation between TTE and CMR in terms of annulus size (R2 = 0.48, p < 0.001), left ventricular outflow tract (LVOT) diameter (R2 = 0.62, p < 0.001) and left ventricular ejection fraction (LVEF) (R2 = 0.47, p < 0.001) and a moderate correlation in terms of aortic valve area (AVA) (R2 = 0.24, p < 0.001). CMR generally tended to report larger values than TTE for all measurements. The Bland-Altman test indicated that the 95% limits of agreement between TTE and CMR ranged from -5.6 mm to + 1.0 mm for annulus size, from -0.45 mm to + 0.25 mm for LVOT, from -0.45 mm2 to + 0.25 mm2 for AVA and from -29.2% to 13.2% for LVEF. CONCLUSIONS: In elderly patients candidates to TAVI, CMR represents a viable complement to transthoracic echocardiography.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Itália , Modelos Lineares , Masculino , Seleção de Pacientes , Projetos Piloto , Valor Preditivo dos Testes , Desenho de Prótese , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Ultrassonografia , Função Ventricular Esquerda
7.
JACC Cardiovasc Interv ; 4(3): 287-97, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21435606

RESUMO

OBJECTIVES: The aim of this study was to investigate the ability to predict cardiac mortality of the Global Risk Classification (GRC) and the Clinical SYNTAX (Synergy between Percutaneous Coronary Intervention with TAXUS and Cardiac Surgery) score (CSS) in left main (LM) patients undergoing percutaneous coronary intervention (PCI) or coronary artery bypass graft (CABG). BACKGROUND: There is a renewed interest in combining clinical and angiographic information to define the risk of patients undergoing LM revascularization. METHODS: The GRC and CSS were assessed in patients undergoing LM PCI (n = 400) or CABG (n = 549). Stand-alone clinical (ACEF [age, creatinine, ejection fraction]), EuroSCORE (European System for Cardiac Operative Risk Evaluation) and angiographic (SYNTAX score) risk scores were also investigated. RESULTS: The GRC (Hosmer-Lemeshow statistic 0.357, p = 0.550; area under the curve 0.743) and the ACEF (Hosmer-Lemeshow 0.426, p = 0.514; area under the curve 0.741) showed the most balanced predictive characteristics in the PCI and CABG cohorts, respectively. In PCI patients, the CSS used fewer data to achieve similar discrimination but poorer calibration than the GRC. Propensity-adjusted outcomes were comparable between PCI and CABG patients with low, intermediate, or high EuroSCORE, ACEF, GRC, and CSS and those with low or intermediate SYNTAX score. Conversely, in the group with the highest SYNTAX score, the risk of cardiac mortality was significantly higher in PCI patients (hazard ratio: 2.323, 95% confidence interval: 1.091 to 4.945, p = 0.029). CONCLUSIONS: In LM patients undergoing PCI, combined scores improve the discrimination accuracy of clinical or angiographic stand-alone tools. In LM patients undergoing CABG, the ACEF score has the best prognostic accuracy compared with other stand-alone or combined scores. The good predictive ability for PCI along with the poor predictive ability for CABG make the SYNTAX score the preferable decision-making tool in LM disease.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Indicadores Básicos de Saúde , Seleção de Pacientes , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 2(3): 197-204, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19463426

RESUMO

OBJECTIVES: This study sought to assess safety and efficacy of implantation of the Catania Coronary Stent System with Nanothin Polyzene-F (CeloNova BioSciences, Newnan, Georgia) in human coronary arteries with clinical data and comprehensive intracoronary imaging. BACKGROUND: Novel approaches to modify stents (e.g., bioactive agents, coatings) have been developed to address the limitations of bare-metal and drug-eluting stents (e.g., restenosis, target lesion revascularization [TLR], late thrombosis). METHODS: This first-in-man study using the Catania stent is a prospective, single center, nonrandomized, single-arm study of 55 patients with symptomatic ischemic heart disease with de novo, obstructive lesions of native coronary arteries. RESULTS: Acute angiographic success was 100%. A core laboratory analyzed quantitative coronary angiography and intravascular ultrasound data immediately after stenting and at 6-month follow-up. Late lumen loss was 0.60 +/- 0.48 mm and the percent neointimal hyperplasia volume was 27.9 +/- 16.1%. In 15 of 55 randomly selected patients, 1,904 cross-sections (19,028 struts) were analyzed at 6 months by optical coherence tomography. Overall, 99.5% of struts were covered. Only 29 of 19,028 struts (0.15%) were malapposed. Binary angiographic restenosis was 6.8%. No death, myocardial infarction, or Academic Research Consortium-defined stent thrombosis was observed at 12 months. The incidence of TLR at 12 months was clinically driven TLR 3.6% (2 of 55) and nonclinically driven TLR 7.3% (4 of 55). CONCLUSIONS: This first-in-man showed an excellent early and mid-term safety profile and high-level efficacy of the new Catania stent in the treatment of de novo coronary lesions in a fairly complex population. Polyzene-F coated stents may be an alternative to both bare-metal and drug-eluting stents with reduced late loss, restenosis, and the TLR without long-term dual antiplatelet therapy.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Stents Farmacológicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção , Função Ventricular Esquerda
9.
Am J Cardiol ; 103(11): 1551-5, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19463514

RESUMO

Drug-eluting stents were devised as an answer to restenosis, but research has shown that the eluting drug can interfere with the blood vessel's healing process, thus increasing the risk of stent thrombosis. A stent coated with the new proprietary polymer Polyzene-F, is a novel technical solution that promises to decrease in-stent restenosis and tackle the risk of thrombosis. Fifty-five patients were enrolled in the first clinical human study (ATLANTA registry), addressing the short-term follow-up results of the CATANIA stent with Polyzene-F. As a part of the study protocol, 15 patients were randomly assigned to optical coherence tomographic (OCT) examination at 6-month follow-up. Optical coherence tomograms were obtained using a Lightlab M2 system with a motorized pull-back at 2.0 mm/s. OCT images were acquired at 15.6 frames/s. A total of 1,904 cross-sectional images with 19,028 struts were analyzed. The rate of covered struts was 99.5%, whereas malapposed struts accounted for 0.15%. Area measurements were performed in 476 cross sections. Neointimal hyperplasia (NIH) area and percent NIH area were 3.2 +/- 1.4 mm2 and 38 +/- 17%, respectively. Percent NIH area was comparable between diabetics and nondiabetics. Qualitative assessment of OCT images demonstrated neither occurrence of stent fractures nor thrombus. In conclusion, OCT assessment of the Polyzene-F-covered stent at follow-up showed a small percentage of neointima. Also, almost complete stent strut coverage was revealed by optical coherence tomography. These figures indicate that the CATANIA stent with Polyzene-F is a promising solution for decreasing late stent restenosis and preventing thrombosis.


Assuntos
Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Isquemia Miocárdica/terapia , Tomografia de Coerência Óptica , Adulto , Idoso , Reestenose Coronária/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Túnica Íntima/patologia
10.
EuroIntervention ; 5(5): 538-43, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20142173

RESUMO

AIMS: At present there exists no direct comparative data for the detection of in-stent tissue coverage as assessed by intravascular ultrasound (IVUS) and optical coherence tomography (OCT) in clinical settings. To explore this subject, we investigated the correlation between the IVUS and OCT measurements derived from a contemporary population. METHODS AND RESULTS: The present study includes 20 patients who had stents imaged at a six months follow-up with both IVUS and OCT, acquired with an automated pull-back. Off-line analyses were done by an independent validated Core-Lab (RHR, Rome, Italy). Measurements of stent length obtained by IVUS and OCT were 16.3+/-3.0 mm and 16.2+/-3.8 mm respectively (p=0.82) and were similar to nominal length (16.3+/-3.3 mm). Luminal area in the OCT image set was lower than that obtained in the corresponding IVUS image set (3.83+/-1.60 mm2 vs 4.05+/-1.44 mm2, p<0.001), while stent area was significantly higher when measured by OCT (6.61+/-1.39 mm2 vs 6.17+/-1.07 mm2, p<0.001). The percentage of tissue coverage measured by IVUS was lower than that measured in the corresponding OCT image sets (35.5+/-16.4% vs 43.4+/-16.1%, p<0.001). Correlation coefficients were high for repeated OCT measurements by two different observers (r=0.99). CONCLUSIONS: OCT can quantify in-stent coverage and detect strut healing with high reproducibility. IVUS tends to underestimate the percentage of in-stent tissue coverage as compared to OCT.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Stents , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Feminino , Humanos , Hiperplasia , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA