Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Contemp Brachytherapy ; 10(1): 73-84, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29619059

RESUMO

PURPOSE: To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. MATERIAL AND METHODS: Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtained for the two source designs using MCNP6, and validated through comparison to a single source dosimetry results in the literature. Dose to water, taking into account the patient specific anatomy and materials (Dw,m), was calculated for all plans using MCNP6, with input files prepared using the BrachyGuide software tool to analyze information from DICOM RT plan exports. RESULTS: A general TG-43 dose overestimation was observed, except for the lungs, with a greater magnitude for 192Ir. The distribution of percentage differences between TG-43 and Monte Carlo (MC) in dose volume histogram (DVH) indices for the planning target volume (PTV) presented small median values (about 2%) for both 60Co and 192Ir, with a greater dispersion for 192Ir. Regarding the organs at risk (OARs), median percentage differences for breast V50% were 3% (5%) for 60Co (192Ir). Differences in median skin D2cc were found comparable, with a larger dispersion for 192Ir, and the same applied to the lung D10cc and the aorta D2cc. TG-43 overestimates D2cc for the rectum and the sigmoid, with median differences from MC within 2% and a greater dispersion for 192Ir. For the bladder, the median of the difference is greater for 60Co (~2%) than for 192Ir (~0.75%), demonstrating however a greater dispersion again for 192Ir. CONCLUSIONS: The magnitude of differences observed between TG-43 based and MC dosimetry and their smaller dispersion relative to 192Ir, suggest that 60Co HDR sources are more amenable to the TG-43 assumptions in clinical treatment planning dosimetry.

2.
Surg Endosc ; 31(12): 5012-5023, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28466361

RESUMO

BACKGROUND: The majority of the current surgical simulators employ specialized sensory equipment for instrument tracking. The Leap Motion controller is a new device able to track linear objects with sub-millimeter accuracy. The aim of this study was to investigate the potential of a virtual reality (VR) simulator for assessment of basic laparoscopic skills, based on the low-cost Leap Motion controller. METHODS: A simple interface was constructed to simulate the insertion point of the instruments into the abdominal cavity. The controller provided information about the position and orientation of the instruments. Custom tools were constructed to simulate the laparoscopic setup. Three basic VR tasks were developed: camera navigation (CN), instrument navigation (IN), and bimanual operation (BO). The experiments were carried out in two simulation centers: MPLSC (Athens, Greece) and CRESENT (Riyadh, Kingdom of Saudi Arabia). Two groups of surgeons (28 experts and 21 novices) participated in the study by performing the VR tasks. Skills assessment metrics included time, pathlength, and two task-specific errors. The face validity of the training scenarios was also investigated via a questionnaire completed by the participants. RESULTS: Expert surgeons significantly outperformed novices in all assessment metrics for IN and BO (p < 0.05). For CN, a significant difference was found in one error metric (p < 0.05). The greatest difference between the performances of the two groups occurred for BO. Qualitative analysis of the instrument trajectory revealed that experts performed more delicate movements compared to novices. Subjects' ratings on the feedback questionnaire highlighted the training value of the system. CONCLUSIONS: This study provides evidence regarding the potential use of the Leap Motion controller for assessment of basic laparoscopic skills. The proposed system allowed the evaluation of dexterity of the hand movements. Future work will involve comparison studies with validated simulators and development of advanced training scenarios on current Leap Motion controller.


Assuntos
Competência Clínica/estatística & dados numéricos , Laparoscopia/educação , Treinamento por Simulação/métodos , Realidade Virtual , Cavidade Abdominal/cirurgia , Humanos , Orientação Espacial , Reprodutibilidade dos Testes , Cirurgiões , Inquéritos e Questionários , Interface Usuário-Computador
3.
Brachytherapy ; 15(2): 252-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26727331

RESUMO

PURPOSE: To develop a user-oriented procedure for testing treatment planning system (TPS) dosimetry in high-dose-rate brachytherapy, with particular focus to TPSs using model-based dose calculation algorithms (MBDCAs). METHODS AND MATERIALS: Identical plans were prepared for three computational models using two commercially available systems and the same (192)Ir source. Reference dose distributions were obtained for each plan using the MCNP v.6.1 Monte Carlo (MC) simulation code with input files prepared via automatic parsing of plan information using a custom software tool. The same tool was used for the comparison of reference dose distributions with corresponding MBDCA exports. RESULTS: The single source test case yielded differences due to the MBDCA spatial discretization settings. These affect points at relatively increased distance from the source, and they are abated in test cases with multiple source dwells. Differences beyond MC Type A uncertainty were also observed very close to the source(s), close to the test geometry boundaries, and within heterogeneities. Both MBDCAs studied were found equivalent to MC within 5 cm from the target volume for a clinical breast brachytherapy test case. These are in agreement with previous findings of MBDCA benchmarking in the literature. CONCLUSIONS: The data and the tools presented in this work, that are freely available via the web, can serve as a benchmark for advanced clinical users developing their own tests, a complete commissioning procedure for new adopters of currently available TPSs using MBDCAs, a quality assurance testing tool for future updates of already installed TPSs, or as an admission prerequisite in multicentric clinical trials.


Assuntos
Algoritmos , Braquiterapia/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Mama , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica , Incerteza
4.
J Appl Clin Med Phys ; 16(1): 5136, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25679171

RESUMO

This work presents BrachyGuide, a brachytherapy-dedicated software tool for the automatic preparation of input files for Monte Carlo simulation from treatment plans exported in DICOM RT format, and results of calculations performed for its benchmarking. Three plans were prepared using two computational models, the image series of a water sphere and a multicatheter breast brachytherapy patient, for each of two commercially available treatment planning systems: BrachyVision and Oncentra Brachy. One plan involved a single source dwell position of an 192Ir HDR source (VS2000 or mHDR-v2) at the center of the water sphere using the TG43 algorithm, and the other two corresponded to the TG43 and advanced dose calculation algorithm for the multicatheter breast brachytherapy patient. Monte Carlo input files were prepared using BrachyGuide and simulations were performed with MCNP v.6.1. For the TG43 patient plans, the Monte Carlo computational model was manually edited in the prepared input files to resemble TG43 dosimetry assumptions. Hence all DICOM RT dose exports were equivalent to corresponding simulation results and their comparison was used for benchmarking the use of BrachyGuide. Monte Carlo simulation results and corresponding DICOM RT dose exports agree within type A uncertainties in the majority of points in the computational models. Treatment planning system, algorithm, and source specific differences greater than type A uncertainties were also observed, but these were explained by treatment planning system-related issues and other sources of type B uncertainty. These differences have to be taken into account in commissioning procedures of brachytherapy dosimetry algorithms. BrachyGuide is accurate and effective for use in the preparation of commissioning tests for new brachytherapy dosimetry algorithms as a user-oriented commissioning tool and the expedition of retrospective patient cohort studies of dosimetry planning.


Assuntos
Algoritmos , Braquiterapia/instrumentação , Simulação por Computador , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica
5.
Surg Endosc ; 29(8): 2224-34, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25303925

RESUMO

INTRODUCTION: Over the past decade, simulation-based training has come to the foreground as an efficient method for training and assessment of surgical skills in minimal invasive surgery. Box-trainers and virtual reality (VR) simulators have been introduced in the teaching curricula and have substituted to some extent the traditional model of training based on animals or cadavers. Augmented reality (AR) is a new technology that allows blending of VR elements and real objects within a real-world scene. In this paper, we present a novel AR simulator for assessment of basic laparoscopic skills. METHODS: The components of the proposed system include: a box-trainer, a camera and a set of laparoscopic tools equipped with custom-made sensors that allow interaction with VR training elements. Three AR tasks were developed, focusing on basic skills such as perception of depth of field, hand-eye coordination and bimanual operation. The construct validity of the system was evaluated via a comparison between two experience groups: novices with no experience in laparoscopic surgery and experienced surgeons. The observed metrics included task execution time, tool pathlength and two task-specific errors. The study also included a feedback questionnaire requiring participants to evaluate the face-validity of the system. RESULTS: Between-group comparison demonstrated highly significant differences (<0.01) in all performance metrics and tasks denoting the simulator's construct validity. Qualitative analysis on the instruments' trajectories highlighted differences between novices and experts regarding smoothness and economy of motion. Subjects' ratings on the feedback questionnaire highlighted the face-validity of the training system. CONCLUSIONS: The results highlight the potential of the proposed simulator to discriminate groups with different expertise providing a proof of concept for the potential use of AR as a core technology for laparoscopic simulation training.


Assuntos
Laparoscopia/educação , Interface Usuário-Computador , Simulação por Computador , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA