RESUMO
The diagnosis of abdominal tuberculosis (aTB) is challenging and there is an urgent need for an accurate diagnostic test. We have developed a high affinity DNA aptamer against GlcB antigen of Mycobacterium tuberculosis (Mtb). We further compared the diagnostic utility of in-house-generated high affinity DNA aptamers and polyclonal antibodies against two Mtb antigens, namely GlcB and HspX, in ascitic fluid samples. These diagnostic reagents were assessed in patients (n = 94) who were categorized as 'Definite TB', 'Probable TB', 'Possible TB' (taken together as aTB) and 'Non-TB' disease. Receiver operating characteristic curves were used to derive cut-off values to provide ≥93% specificity. Aptamer Linked Immobilized Sorbent Assay (ALISA) for HspX and GlcB exhibited a sensitivity of â¼84% and 50%, respectively (p-value <0.01). In contrast, antibody-based ELISA exhibited a lower sensitivity of â¼18% and â¼28% for HspX and GlcB, respectively (p-value <0.0001 and p = 0.05 for HspX and GlcB ELISA vs. ALISA, respectively). HspX ALISA detected 32/38 aTB cases, while Xpert detected only 9 samples. In conclusion, HspX aptamer-based test was found to be superior to the other tests for diagnosing aTB and it nearly fulfils the sensitivity criteria of WHO's 'Target Product Profile' for extrapulmonary tuberculosis (sensitivity ≥80%, specificity 98%).
Assuntos
Aptâmeros de Nucleotídeos , Mycobacterium tuberculosis , Tuberculose , Antígenos de Bactérias/genética , Aptâmeros de Nucleotídeos/genética , Proteínas de Bactérias/genética , Humanos , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Tuberculose/diagnósticoRESUMO
Pulmonary tuberculosis is the most common manifestation of tuberculosis, and to this day, sputum smear microscopy remains the most widely used diagnostic test in resource-limited settings despite its suboptimal sensitivity. Here we report the development of two DNA aptamer-based diagnostic tests, namely aptamer linked immobilized sorbent assay (Aptamer ALISA) and electrochemical sensor (ECS), for the direct detection of a TB biomarker HspX in sputum. First we compared the performance of Aptamer ALISA with anti-HspX polyclonal antibody-based enzyme linked immunosorbent assay (Antibody ELISA) in a blinded study of 314 sputum specimens. Aptamer ALISA displayed a high sensitivity of 94.1% (95% CI 86.8-98%) as compared to 68.2% sensitivity (95% CI 57.2-77.9%) of Antibody ELISA ( p-value < 0.05) using culture as the reference standard without compromising test specificity of 100%. Out of nine smear-negative culture-positive samples, six were positive by Aptamer ALISA and only two were detected by Antibody ELISA. ALISA detected as positive 80 of 85 culture-positive TB as compared to 57 of 81 diagnosed as TB by X-ray ( p-value < 0.0001). These findings demonstrate the superiority of the aptamer-based test over smear microscopy, antibody-based ELISA, and chest X-ray for TB detection ( p-value < 0.0001 for all). Further, we have developed a â¼30 min point-of-care ECS test that discriminates between tuberculous and nontuberculous sputum with a sensitivity of â¼92.3% and specificity of 91.2%. The tests developed in the current study cost â¼$1-3/test and have potential utility in active case finding in high-risk groups and screening for pulmonary TB among presumptive TB subjects.