Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 3: CD010890, 2022 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-35320584

RESUMO

BACKGROUND: Systematic screening in high-burden settings is recommended as a strategy for early detection of pulmonary tuberculosis disease, reducing mortality, morbidity and transmission, and improving equity in access to care. Questioning for symptoms and chest radiography (CXR) have historically been the most widely available tools to screen for tuberculosis disease. Their accuracy is important for the design of tuberculosis screening programmes and determines, in combination with the accuracy of confirmatory diagnostic tests, the yield of a screening programme and the burden on individuals and the health service. OBJECTIVES: To assess the sensitivity and specificity of questioning for the presence of one or more tuberculosis symptoms or symptom combinations, CXR, and combinations of these as screening tools for detecting bacteriologically confirmed pulmonary tuberculosis disease in HIV-negative adults and adults with unknown HIV status who are considered eligible for systematic screening for tuberculosis disease. Second, to investigate sources of heterogeneity, especially in relation to regional, epidemiological, and demographic characteristics of the study populations. SEARCH METHODS: We searched the MEDLINE, Embase, LILACS, and HTA (Health Technology Assessment) databases using pre-specified search terms and consulted experts for unpublished reports, for the period 1992 to 2018. The search date was 10 December 2018. This search was repeated on 2 July 2021. SELECTION CRITERIA: Studies were eligible if participants were screened for tuberculosis disease using symptom questions, or abnormalities on CXR, or both, and were offered confirmatory testing with a reference standard. We included studies if diagnostic two-by-two tables could be generated for one or more index tests, even if not all participants were subjected to a microbacteriological reference standard. We excluded studies evaluating self-reporting of symptoms. DATA COLLECTION AND ANALYSIS: We categorized symptom and CXR index tests according to commonly used definitions. We assessed the methodological quality of included studies using the QUADAS-2 instrument. We examined the forest plots and receiver operating characteristic plots visually for heterogeneity. We estimated summary sensitivities and specificities (and 95% confidence intervals (CI)) for each index test using bivariate random-effects methods. We analyzed potential sources of heterogeneity in a hierarchical mixed-model. MAIN RESULTS: The electronic database search identified 9473 titles and abstracts. Through expert consultation, we identified 31 reports on national tuberculosis prevalence surveys as eligible (of which eight were already captured in the search of the electronic databases), and we identified 957 potentially relevant articles through reference checking. After removal of duplicates, we assessed 10,415 titles and abstracts, of which we identified 430 (4%) for full text review, whereafter we excluded 364 articles. In total, 66 articles provided data on 59 studies. We assessed the 2 July 2021 search results; seven studies were potentially eligible but would make no material difference to the review findings or grading of the evidence, and were not added in this edition of the review. We judged most studies at high risk of bias in one or more domains, most commonly because of incorporation bias and verification bias. We judged applicability concerns low in more than 80% of studies in all three domains. The three most common symptom index tests, cough for two or more weeks (41 studies), any cough (21 studies), and any tuberculosis symptom (29 studies), showed a summary sensitivity of 42.1% (95% CI 36.6% to 47.7%), 51.3% (95% CI 42.8% to 59.7%), and 70.6% (95% CI 61.7% to 78.2%, all very low-certainty evidence), and a specificity of 94.4% (95% CI 92.6% to 95.8%, high-certainty evidence), 87.6% (95% CI 81.6% to 91.8%, low-certainty evidence), and 65.1% (95% CI 53.3% to 75.4%, low-certainty evidence), respectively. The data on symptom index tests were more heterogenous than those for CXR. The studies on any tuberculosis symptom were the most heterogeneous, but had the lowest number of variables explaining this variation. Symptom index tests also showed regional variation. The summary sensitivity of any CXR abnormality (23 studies) was 94.7% (95% CI 92.2% to 96.4%, very low-certainty evidence) and 84.8% (95% CI 76.7% to 90.4%, low-certainty evidence) for CXR abnormalities suggestive of tuberculosis (19 studies), and specificity was 89.1% (95% CI 85.6% to 91.8%, low-certainty evidence) and 95.6% (95% CI 92.6% to 97.4%, high-certainty evidence), respectively. Sensitivity was more heterogenous than specificity, and could be explained by regional variation. The addition of cough for two or more weeks, whether to any (pulmonary) CXR abnormality or to CXR abnormalities suggestive of tuberculosis, resulted in a summary sensitivity and specificity of 99.2% (95% CI 96.8% to 99.8%) and 84.9% (95% CI 81.2% to 88.1%) (15 studies; certainty of evidence not assessed). AUTHORS' CONCLUSIONS: The summary estimates of the symptom and CXR index tests may inform the choice of screening and diagnostic algorithms in any given setting or country where screening for tuberculosis is being implemented. The high sensitivity of CXR index tests, with or without symptom questions in parallel, suggests a high yield of persons with tuberculosis disease. However, additional considerations will determine the design of screening and diagnostic algorithms, such as the availability and accessibility of CXR facilities or the resources to fund them, and the need for more or fewer diagnostic tests to confirm the diagnosis (depending on screening test specificity), which also has resource implications. These review findings should be interpreted with caution due to methodological limitations in the included studies and regional variation in sensitivity and specificity. The sensitivity and specificity of an index test in a specific setting cannot be predicted with great precision due to heterogeneity. This should be borne in mind when planning for and implementing tuberculosis screening programmes.


Assuntos
Infecções por HIV , Tuberculose Pulmonar , Adulto , Tosse , Infecções por HIV/complicações , Humanos , Programas de Rastreamento , Radiografia , Sensibilidade e Especificidade , Tuberculose Pulmonar/diagnóstico por imagem , Tuberculose Pulmonar/epidemiologia
4.
J Clin Epidemiol ; 127: 167-174, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32798714

RESUMO

OBJECTIVES: Comparative diagnostic test accuracy systematic reviews (DTA reviews) assess the accuracy of two or more tests and compare their diagnostic performance. We investigated how comparative DTA reviews assessed the risk of bias (RoB) in primary studies that compared multiple index tests. STUDY DESIGN AND SETTING: This is an overview of comparative DTA reviews indexed in MEDLINE from January 1st to December 31st, 2017. Two assessors independently identified DTA reviews including at least two index tests and containing at least one statement in which the accuracy of the index tests was compared. Two assessors independently extracted data on the methods used to assess RoB in studies that directly compared the accuracy of multiple index tests. RESULTS: We included 238 comparative DTA reviews. Only two reviews (0.8%, 95% confidence interval 0.1 to 3.0%) conducted RoB assessment of test comparisons undertaken in primary studies; neither used an RoB tool specifically designed to assess bias in test comparisons. CONCLUSION: Assessment of RoB in test comparisons undertaken in primary studies was uncommon in comparative DTA reviews, possibly due to lack of existing guidance on and awareness of potential sources of bias. Based on our findings, guidance on how to assess and incorporate RoB in comparative DTA reviews is needed.


Assuntos
Viés , Testes Diagnósticos de Rotina/normas , Revisões Sistemáticas como Assunto , Intervalos de Confiança , Confiabilidade dos Dados , Humanos
5.
J Clin Epidemiol ; 122: 129-141, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32060007

RESUMO

OBJECTIVES: This article provides updated GRADE guidance about how authors of systematic reviews and health technology assessments and guideline developers can assess the results and the certainty of evidence (also known as quality of the evidence or confidence in the estimates) of a body of evidence addressing test accuracy (TA). STUDY DESIGN AND SETTING: We present an overview of the GRADE approach and guidance for rating certainty in TA in clinical and public health and review the presentation of results of a body of evidence regarding tests. Part 1 of the two parts in this 21st guidance article about how to apply GRADE focuses on understanding study design issues in test accuracy, provide an overview of the domains, and describe risk of bias and indirectness specifically. RESULTS: Supplemented by practical examples, we describe how raters of the evidence using GRADE can evaluate study designs focusing on tests and how they apply the GRADE domains risk of bias and indirectness to a body of evidence of TA studies. CONCLUSION: Rating the certainty of a body of evidence using GRADE in Cochrane and other reviews and World Health Organization and other guidelines dealing with in TA studies helped refining our approach. The resulting guidance will help applying GRADE successfully for questions and recommendations focusing on tests.


Assuntos
Pesquisa Biomédica/normas , Confiabilidade dos Dados , Abordagem GRADE/normas , Guias como Assunto , Viés de Publicação/estatística & dados numéricos , Projetos de Pesquisa/normas , Humanos
6.
J Clin Epidemiol ; 122: 142-152, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32058069

RESUMO

OBJECTIVES: This article provides updated GRADE guidance about how authors of systematic reviews and health technology assessments and guideline developers can rate the certainty of evidence (also known as quality of the evidence or confidence in the estimates) of a body of evidence addressing test accuracy (TA) on the domains imprecision, inconsistency, publication bias, and other domains. It also provides guidance for how to present synthesized information in evidence profiles and summary of findings tables. STUDY DESIGN AND SETTING: We present guidance for rating certainty in TA in clinical and public health and review the presentation of results of a body of evidence regarding tests. RESULTS: Supplemented by practical examples, we describe how raters of the evidence can apply the GRADE domains inconsistency, imprecision, and publication bias to a body of evidence of TA studies. CONCLUSION: Using GRADE in Cochrane and other reviews as well as World Health Organization and other guidelines helped refining the GRADE approach for rating the certainty of a body of evidence from TA studies. Although several of the GRADE domains (e.g., imprecision and magnitude of the association) require further methodological research to help operationalize them, judgments need to be made on the basis of what is known so far.


Assuntos
Pesquisa Biomédica/normas , Confiabilidade dos Dados , Abordagem GRADE/normas , Guias como Assunto , Viés de Publicação/estatística & dados numéricos , Projetos de Pesquisa/normas , Humanos
7.
J Clin Epidemiol ; 117: 138-148, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31112801

RESUMO

OBJECTIVE: The objective of the study was to clarify how the Grading of Recommendations Assessment, Development and Evaluation (GRADE) concept of certainty of evidence applies to certainty ratings of test accuracy. STUDY DESIGN AND SETTING: After initial brainstorming with GRADE Working Group members, we iteratively refined and clarified the approaches for defining ranges when assessing the certainty of evidence for test accuracy within a systematic review, health technology assessment, or guideline. RESULTS: Ranges can be defined both for single test accuracy and for comparative accuracy of multiple tests. For systematic reviews and health technology assessments, approaches for defining ranges include some that do not require value judgments regarding downstream health outcomes. Key challenges arise in the context of a guideline that requires ranges for sensitivity and specificity that are set considering possible effects on all critical outcomes. We illustrate possible approaches and provide an example from a systematic review of a direct comparison between two test strategies. CONCLUSIONS: This GRADE concept paper provides a framework for assessing, presenting, and making decisions based on the certainty of evidence for test accuracy. More empirical research is needed to support future GRADE guidance on how to best operationalize the candidate approaches.


Assuntos
Técnicas e Procedimentos Diagnósticos/normas , Avaliação da Tecnologia Biomédica/métodos , Tomada de Decisões , Humanos , Sensibilidade e Especificidade , Revisões Sistemáticas como Assunto
8.
Cochrane Database Syst Rev ; (3): CD009579, 2015 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-25758180

RESUMO

BACKGROUND: Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. OBJECTIVES: To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. SEARCH METHODS: We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. SELECTION CRITERIA: We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). MAIN RESULTS: We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). AUTHORS' CONCLUSIONS: Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.


Assuntos
Fitas Reagentes , Schistosoma haematobium , Schistosoma mansoni , Esquistossomose Urinária/diagnóstico , Esquistossomose mansoni/diagnóstico , Adulto , Animais , Antígenos de Helmintos/sangue , Criança , Estudos Transversais , Feminino , Hematúria/diagnóstico , Humanos , Masculino , Microscopia , Prevalência , Proteinúria/diagnóstico , Padrões de Referência , Schistosoma haematobium/imunologia , Schistosoma mansoni/imunologia , Esquistossomose Urinária/sangue , Esquistossomose Urinária/imunologia , Esquistossomose Urinária/urina , Esquistossomose mansoni/sangue , Esquistossomose mansoni/imunologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
9.
J Clin Epidemiol ; 67(7): 760-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24725643

RESUMO

OBJECTIVES: The Grading of Recommendations Assessment, Development and Evaluation (GRADE) Working Group developed an approach to assess the quality of evidence of diagnostic tests. Its use in Cochrane diagnostic test accuracy reviews is new. We applied this approach to three Cochrane reviews with the aim of better understanding the application of the GRADE criteria to such reviews. STUDY DESIGN AND SETTING: We selected reviews to achieve clinical and methodological diversities. At least three assessors independently assessed each review according to the GRADE criteria of risk of bias, indirectness, imprecision, inconsistency, and publication bias. Two teleconferences were held to share experiences. RESULTS: For the interpretation of the GRADE criteria, it made a difference whether assessors looked at the evidence from a patient-important outcome perspective or from a test accuracy standpoint. GRADE criteria such as inconsistency, imprecision, and publication bias were challenging to apply as was the assessment of comparative test accuracy reviews. CONCLUSION: The perspective from which evidence is graded can influence judgments about quality. Guidance on application of GRADE to comparative test reviews and on the GRADE criteria of inconsistency, imprecision, and publication bias will facilitate the operationalization of GRADE for diagnostics.


Assuntos
Testes Diagnósticos de Rotina/normas , Medicina Baseada em Evidências/normas , Humanos , Viés de Publicação , Literatura de Revisão como Assunto
10.
Ann Intern Med ; 155(8): 529-36, 2011 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-22007046

RESUMO

In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.


Assuntos
Diagnóstico , Literatura de Revisão como Assunto , Inquéritos e Questionários , Viés , Medicina Baseada em Evidências , Humanos , Seleção de Pacientes , Controle de Qualidade , Padrões de Referência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA