Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
NMR Biomed ; : e5174, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712650

RESUMO

The aim of the current study is to investigate the diagnostic value of R2* mapping versus reduced field-of-view diffusion-weighted imaging (rDWI) of the primary lesion of rectal cancer for preoperative prediction of nonenlarged lymph node metastasis (NLNM). Eighty-one patients with pathologically confirmed rectal cancer underwent preoperative R2* mapping and rDWI sequences before total mesorectal excisions and accompanying regional lymph node dissections. Two radiologists independently performed whole-tumor measurements of R2* and apparent diffusion coefficient (ADC) parameters on primary lesions of rectal cancer. Patients were divided into positive (NLNM+) and negative (NLNM-) groups based on their pathological analysis. The tumor location, maximum diameter of the tumor, and maximum short diameter of the lymph node were assessed. R2* and ADC, pT stage, tumor grade, status of mesorectal fascia, and extramural vascular invasion were also studied for their potential relationships with NLNM using multivariate logistic regression analysis. The NLNM+ group had significantly higher R2* (43.56 ± 8.43 vs. 33.87 ± 9.57, p < 0.001) and lower ADC (1.00 ± 0.13 vs. 1.06 ± 0.22, p = 0.036) than the NLNM- group. R2* and ADC were correlated to lymph node metastasis (r = 0.510, p < 0.001 for R2*; r = -0.235, p = 0.035 for ADC). R2* and ADC showed good and moderate diagnostic abilities in the assessment of NLNM status with corresponding area-under-the-curve values of 0.795 and 0.636. R2* provided a significantly better diagnostic performance compared with ADC for the prediction of NLNM status (z = 1.962, p = 0.0498). The multivariate logistic regression analysis demonstrated that R2* was a compelling factor of lymph node metastasis (odds ratio = 56.485, 95% confidence interval: 5.759-554.013; p = 0.001). R2* mapping had significantly higher diagnostic performance than rDWI from the primary tumor of rectal cancer in the prediction of NLNM status.

2.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38271728

RESUMO

Objective. This study aims to develop and assess a tumor contraction model, enhancing the precision of ablative margin (AM) evaluation after microwave ablation (MWA) treatment for hepatocellular carcinomas (HCCs).Approach. We utilize a probabilistic method called the coherent point drift algorithm to align pre-and post-ablation MRI images. Subsequently, a nonlinear regression method quantifies local tumor contraction induced by MWA, utilizing data from 47 HCC with viable ablated tumors in post-ablation MRI. After automatic non-rigid registration, correction for tumor contraction involves contracting the 3D contour of the warped tumor towards its center in all orientations.Main results. We evaluate the performance of our proposed method on 30 HCC patients who underwent MWA. The Dice similarity coefficient between the post-ablation liver and the warped pre-ablation livers is found to be 0.95 ± 0.01, with a mean corresponding distance between the corresponding landmarks measured at 3.25 ± 0.62 mm. Additionally, we conduct a comparative analysis of clinical outcomes assessed through MRI over a 3 month follow-up period, noting that the AM, as evaluated by our proposed method, accurately detects residual tumor after MWA.Significance. Our proposed method showcases a high level of accuracy in MRI liver registration and AM assessment following ablation treatment. It introduces a potentially approach for predicting incomplete ablations and gauging treatment success.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
3.
J Magn Reson Imaging ; 58(3): 879-891, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36527202

RESUMO

BACKGROUND: Immunoglobulin A nephropathy (IgAN) is the most common primary glomerulonephritis worldwide. Oxford classification including mesangial hypercellularity (M), endothelial hypercellularity (E), segmental sclerosis (S), interstitial fibrosis/tubular atrophy (T), and crescent (C) were recommended to predict the prognosis of IgAN. PURPOSE: To explore whether multiparametric magnetic resonance imaging (MRI) can be applied to assess the renal function, Oxford classification, and risk of progression to end-stage kidney disease within 5 years of IgAN. STUDY TYPE: Prospective. POPULATION: A total of 46 patients with pathologically confirmed IgAN and 20 healthy volunteers. FIELD STRENGTH/SEQUENCE: A 3-T, blood oxygenation level-dependent (BOLD)-MRI, intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI). ASSESSMENT: Two radiologists measured the cortex and medulla T2*, apparent diffusion coefficient (ADC), true diffusion (Dt), pseudo-diffusion (Dp), perfusion fraction (fp). All participants were divided into three groups: group 1, healthy volunteers; group 2, patients with estimated glomerular filtration rate (eGFR) ≥60 mL/min/1.73 m2 ; group 3, patients with eGFR <60 mL/min/1.73 m2 . Or two groups: group A, 5-year risk scores ≤10% and group B, 5-year risk scores >10%. STATISTICAL TESTS: Intraclass correlation coefficient, one-way analysis of variance, least-significant difference, Student's t-test, Pearson product-moment correlation, Spearman's rank correlation, and receiver operating characteristics (ROC) with the area under the curve (AUC). A P value <0.05 was considered statistically significant. RESULTS: Except for cortical Dp, all other MRI parameters showed significant differences between group 1 and group 2. None of the MRI parameters showed a significant correlation with M, E, or C scores. Cortical T2*, Dt, fp, and medullary Dt and fp showed low-to-moderate significant correlations with S scores. Except for cortical and medullary Dp, all other MRI parameters were significantly correlated with T scores. Cortical Dt showed the largest AUC for differentiating group A from group B (AUC = 0.927) and T0 from T1/T2 (AUC = 0.963). DATA CONCLUSION: Imaging by IVIM-DWI and BOLD-MRI could facilitate noninvasive assessment of the renal function, Oxford classification, and prognostic risk of IgAN patients. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 3.


Assuntos
Glomerulonefrite por IGA , Imageamento por Ressonância Magnética Multiparamétrica , Humanos , Glomerulonefrite por IGA/diagnóstico por imagem , Prognóstico , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Rim/diagnóstico por imagem , Rim/fisiologia , Medição de Risco
4.
Jpn J Radiol ; 41(2): 180-193, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36255600

RESUMO

PURPOSE: To investigate the potential of histogram analysis based on diffusion kurtosis imaging (DKI) in evaluating renal function and fibrosis associated with chronic kidney disease (CKD). MATERIALS AND METHODS: Thirty-six CKD patients were enrolled, and DKI was performed in all patients before the renal biopsy. The histogram parameters of diffusivity (D) and kurtosis (K) were obtained using FireVoxel. The histogram parameters between the stable [estimated glomerular filtration rate (eGFR) ≥ 60 ml/min/1.73 m2] and impaired (eGFR < 60 ml/min/1.73 m2) eGFR group were compared. Besides, patients were classified into mild, moderate, and severe fibrosis group using a semi-quantitative standard. The correlations of histogram parameters with eGFR and fibrosis scores were investigated and the diagnostic performances of histogram parameters in assessing renal dysfunction and fibrosis were analyzed. The added value of combination of most significant parameter with 24 h urinary protein (24 h-UPRO) in evaluating fibrosis was also explored. RESULTS: Seven D histogram parameters in cortex (mean, median, 10th, 25th, 75th, 90th percentiles and entropy), two D histogram parameters in medulla (75th, 90th percentiles), seven K histogram parameters in cortex (mean, min, median, 10th, 25th, 75th, 90th percentiles) and three K histogram parameters in medulla (mean, median, 25th percentile) were significantly different between the two groups. The Dmean of cortex was the most relevant parameter to eGFR (r = 0.648, P < 0.001) and had the largest area under the curve (AUC) for differentiating the stable from impaired eGFR group [AUC = 0.889; 95% confidence interval (CI) 0.728-0.970]. The K90th of cortex presented the strongest correlation with fibrosis scores (r = 0.575, P < 0.001) and achieved the largest AUC for distinguishing the mild from moderate to severe fibrosis group (AUC = 0.849, 95% CI 0.706-0.993). Combining the K90th in cortex with 24 h-UPRO gained statistically higher AUC value (AUC = 0.880, 95% CI 0.763-0.996). CONCLUSION: Histogram analysis based on DKI is practicable for the noninvasive assessment of renal function and fibrosis in CKD patients.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Curva ROC , Imagem de Difusão por Ressonância Magnética/métodos , Estudos Retrospectivos , Fibrose , Rim/diagnóstico por imagem , Rim/fisiologia
5.
Insights Imaging ; 13(1): 18, 2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35092495

RESUMO

OBJECTIVES: To explore the diagnostic performance of diffusion kurtosis imaging (DKI) in evaluating the clinical and pathological characteristics of patients with immunoglobulin A nephropathy (IgAN) compared with conventional DWI. MATERIALS AND METHODS: A total of 28 IgAN patients and 14 healthy volunteers prospectively underwent MRI examinations including coronal T2WI, axial T1WI, T2WI, and DWI sequences from September 2020 to August 2021. We measured mean kurtosis (MK), mean diffusivity (MD), and apparent diffusion coefficient (ADC) by using MR Body Diffusion Toolbox v1.4.0 (Siemens Healthcare). Patients were divided into three groups according to their estimated glomerular filtration rate (eGFR) (Group1, healthy volunteers without kidney disease or other diseases that affect renal function; Group2, IgAN patients with eGFR > 60 mL/min/1.73 m2; Group3, IgAN patients with eGFR < 60 mL/min/1.73 m2). One-way analysis of variance, Pearson or Spearman correlation, and receiver operating characteristic curves were applied in our statistical analysis. RESULTS: MKCortex and ADCCortex showed significant differences between the Group1 and Group2. MKCortex, MDCortex, ADCCortex, MKMedulla, and ADCMedulla showed significant differences between Group2 and Group3. MKCortex had the highest correlation with CKD stages (r = 0.749, p < 0.001), and tubulointerstitial lesion score (r = 0.656, p < 0.001). MDCortex had the highest correlation with glomerular lesion score (r = - 0.475, p = 0.011). MKCortex had the highest AUC (AUC = 0.923) for differentiating Group1 from Group2, and MDCortex had the highest AUC (AUC = 0.924) for differentiating Group2 from Group3, followed by MKMedulla (AUC = 0.923). CONCLUSIONS: DKI is a feasible and reliable technique that can assess the clinical and pathological characteristics of IgAN patients and can provide more valuable information than conventional DWI, especially MKCortex.

6.
Ultraschall Med ; 43(2): e1-e10, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33910257

RESUMO

PURPOSE: To explore the usefulness of liver stiffness measurements (LSMs) by sound touch elastography (STE) and sound touch quantification (STQ) in chronic hepatitis B (CHB) patients for staging fibrosis. METHODS: This prospective multicenter study recruited normal volunteers and CHB patients between May 2018 and October 2019. The volunteers underwent LSM by STE and supersonic shear imaging (SSI) or by STQ and acoustic radiation force impulse imaging (ARFI). CHB patients underwent liver biopsy and LSM by both STE/STQ. The areas under the receiver operating characteristic curves (AUCs) for staging fibrosis were calculated. RESULTS: Overall, 97 volunteers and 524 CHB patients were finally eligible for the study. The successful STE and STQ measurement rates were both 100 % in volunteers and 99.4 % in CHB patients. The intraclass correlation coefficients (ICCs) for the intra-observer stability of STE and STQ (0.94; 0.90) were similar to those of SSI and ARFI (0.95; 0.87), respectively. STE and STQ showed better accuracy than the aspartate aminotransferase-to-platelet ratio index (APRI) and fibrosis-4 index (FIB-4) (AUC: 0.87 vs 0.86 vs 0.73 vs 0.77) in staging cirrhosis. However, both STE and STQ were not superior to APRI and FIB-4 in staging significant fibrosis (AUC: 0.76 vs 0.73 vs 0.70 vs 0.71, all P-values > 0.05). CONCLUSION: STE and STQ are convenient techniques with a reliable LSM value. They have a similar diagnostic performance and are superior to serum biomarkers in staging cirrhosis in CHB patients.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite B Crônica , Aspartato Aminotransferases , Biópsia , Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/complicações , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Prospectivos , Curva ROC
7.
Ann Transl Med ; 9(21): 1614, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34926658

RESUMO

BACKGROUND: The incidence of chronic kidney disease (CKD) is high, and is easy to develop into end-stage renal disease (ESRD), which requires kidney dialysis or kidney transplantation. Therefore, we want to explore the clinical value of magnetic resonance quantitative histogram analysis based on spatial labeling with multiple inversion pulses (SLEEK) in assessing renal function in the early stage. METHODS: One hundred and twenty-nine patients underwent abdominal MRI examination, including a coronal SLEEK sequence. The patients were divided into the control group [CG, 47 cases, estimated glomerular filtration rate (eGFR) >90], the mild renal function impairment (mRI) group (48 cases, eGFR =60-90), and the moderate to severe renal function impairment (m-sRI) group (34 cases, eGFR <60). Two experienced radiologists delineated cortex and medulla regions of interest (ROIs) on SLEEK images to obtain cortex and medulla quantitative histogram parameters [Mean, Median, Percentiles (5th, 10th, 25th, 75th, and 90th), Skewness, Kurtosis, and Entropy] using FireVoxel. These histogram parameters were compared by proper statistical methods such as one-way analysis of variance, the χ2 test, and receiver operating characteristic (ROC) curve analysis. RESULTS: Four histogram parameters (Inhomogeneitycortex, Skewnesscortex, Kurtosismedulla, and Entropymedulla) differed significantly between the CG and the mRI group. One medulla (Entropymedulla) and nine cortex (Meancortex, Mediancortex, Kurtosiscortex, Entropycortex, and 5th, 10th, 25th, 75th, and 90th Percentilecortex) histogram parameters were significantly different between the m-RI and m-sRI groups. The most relevant parameter to eGFR was Inhomogenitycortex (r=-0.450, P<0.001). Inhomogeneitycortex had the largest area under the curve (AUC) for differentiating the mRI group from the CG (AUC =0.718; 95% CI: 0.616-0.806), while 25th Percentilecortex generated the largest AUC (AUC =0.786; 95% CI: 0.681-0.869) for differentiating the mRI and m-sRI groups. CONCLUSIONS: Quantitative histogram parameters based on a SLEEK sequence can be used to supplement renal dysfunction assessment. Cortex histogram parameters are more valuable for evaluating renal function than medulla histogram parameters.

8.
Insights Imaging ; 12(1): 146, 2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34674043

RESUMO

OBJECTIVES: To explore whether multiparametric approach including blood oxygenation level-dependent MRI (BOLD-MRI) and intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) can be applied in the assessment of renal function in children with chronic kidney disease (CKD). MATERIALS AND METHODS: This prospective study included 74 children (CKD stage 1-3, 51; CKD stage 4-5, 12; healthy volunteers, 11) for renal MRI examinations including coronal T2WI, axial T1WI and T2WI, BOLD-MRI, and DWI sequences. We measured the renal cortex and medulla T2*, ADC, Dt, Dp, and fp values on BOLD and DWI images. Appropriate statistical methods were applied for comparing MRI-derived parameters among the three groups and calculating the correlation coefficients between MRI-derived parameters and clinical data. Receiver operating characteristic (ROC) curves were used to assess the diagnostic performance of MRI-derived parameters. RESULTS: There were significant differences in cortex T2*, ADC, Dt, fp and medulla T2*, ADC, Dt among the three groups. Cortex T2*, ADC, Dt, fp and medulla T2*, ADC, Dt had a trend: CKD stage 4-5 < CKD stage 1-3 < healthy volunteers. Cortex and medulla T2*, ADC, Dt were significantly correlated with eGFR, serum creatinine (Scr), cystatin C. In addition, cortex T2* and eGFR showed the highest correlation coefficient (r = 0.824, p < 0.001). Cortex Dt and medulla T2* were optimal parameters for differentiating healthy volunteers and CKD stage 1-3 or CKD stage 4-5 and CKD stage 1-3, respectively. CONCLUSIONS: BOLD-MRI and IVIM-DWI might be used as a feasible method for noninvasive assessment of renal function in children with CKD.

9.
Abdom Radiol (NY) ; 46(10): 4647-4659, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34136936

RESUMO

OBJECTIVES: To assess the respective diagnostic value of Sonazoid™ and SonoVue® for characterizing FLLs as benign or malignant and the corresponding safety. METHODS: This prospective Phase 3 study was conducted at 17 centres in China and Korea (May 2014 to April 2015); 424 patients (20 to 80 years) with at least 1 untreated focal liver lesion (FLL) (< 10 cm in diameter) underwent a contrast-enhanced ultrasound (CEUS) examination (218 received Sonazoid of 0.12 µL microbubbles/kg; 206 received SonoVue of 2.4 mL). Three independent blinded readers evaluated pre- and post-contrast images characterising the FLLs as benign or malignant. RESULTS: Sonazoid-enhanced and SonoVue-enhanced ultrasound provided a statistically significant improvement in specificity for all 3 readers comparing to unenhanced ultrasound (for Sonazoid: p = 0.0093, < 0.0001, 0.0011; for SonoVue: p = 0.002, 0.03, 0.12, respectively). Difference in accuracy improvement between the 2 groups was within the pre-specified non-inferiority margin of 20% for all 3 readers (6.1%, 95% CI: - 5.0 to 17.2; - 7.5%, 95% CI: - 18.4 to 3.5; - 0.3%, 95% CI: - 11.3 to 10.7). The diagnostic confidence level for all 3 readers increased with post-contrast images relative to pre-contrast images. Both contrast agents were well tolerated. CONCLUSION: Results showed a similar efficacy for Sonazoid™ and SonoVue® in diagnosing FLLs as benign or malignant, and underlined the benefit of CEUS imaging over unenhanced ultrasound imaging in reaching a confident diagnosis without having to refer patients for additional imaging exams.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Compostos Férricos , Humanos , Ferro , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Óxidos , Fosfolipídeos , Estudos Prospectivos , Sensibilidade e Especificidade , Hexafluoreto de Enxofre , Ultrassonografia
10.
Cardiovasc Intervent Radiol ; 44(2): 261-270, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33057809

RESUMO

OBJECTIVE: To determine whether albumin-bilirubin (ALBI) grade could be used to predict the outcomes of patients with intrahepatic cholangiocarcinoma (ICC) who underwent ultrasound-guided percutaneous microwave ablation (MWA). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. We studied 52 treatment-naïve patients with 74 ICC lesions according to the Milan criteria who subsequently underwent MWA from April 2011 to March 2018. Overall survival (OS) and recurrence-free survival (RFS) were compared in groups classified by Child-Pugh score and ALBI grade, which were statistically analyzed with the log-rank test. Cox proportional hazard regression analyses were used to determine the prognostic factors for survival in patients with ICC. RESULTS: The median follow-up time was 21.2 months (3.2-78.7 months). Seventeen patients died during this period. After MWA, the cumulative 1-, 3-, and 5-year OS rates were 87.4%, 51.4%, and 35.2%, respectively, and the cumulative 1-, 3-, and 5-year RFS rates were 68.9%, 56.9%, and 56.9%, respectively. The major complication rate was 3.8% (2/52). Stratified according to ALBI grade, the cumulative 1-, 3-, and 5-year OS rates were 95.5%, 72.4%, and 72.4% for patients with ALBI grade 1 and 62.5%, 40.6%, and 36.3% for patients with ALBI grade 2, respectively, showing a significant difference (P = 0.006). Multivariate analysis results showed that older age (hazard ratio [HR]: 1.67, 95% confidence interval [CI]: 1.11-2.82; P = 0.002), tumor size ≥ 3 cm in diameter (HR: 11.33, CI: 2.24-34.52; P = 0.021) and ALBI grade (HR: 8.23, CI: 1.58-58.00; P = 0.004) may be predictors of poor OS. CONCLUSION: ALBI grade was validated as a significant biomarker for predicting survival in ICC patients within the Milan criteria who underwent MWA.


Assuntos
Técnicas de Ablação/métodos , Neoplasias dos Ductos Biliares/cirurgia , Bilirrubina/análise , Colangiocarcinoma/cirurgia , Albumina Sérica/análise , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/cirurgia , Colangiocarcinoma/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Micro-Ondas , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
11.
Eur Radiol ; 31(1): 94-103, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32749582

RESUMO

OBJECTIVES: To assess whether spatial labeling with multiple inversion pulses (SLEEK) sequence can be employed as a one-stop assessment method for evaluating renal function and displaying renal artery in hypertensive patients with suspected renal dysfunction. METHODS: A total of 78 patients with suspected hypertensive renal damage were enrolled in this retrospective study. All patients underwent MRI examinations, and both SLEEK and DWI sequences were performed simultaneously. According to estimated glomerular filtration rate (eGFR), patients were divided into three groups (Group 1, eGFR> 90; Group 2, eGFR = 60-90; Group 3, eGFR< 60). Twenty-two of these patients also underwent CT angiography (CTA) examination. Comparison between CTA, DWI, and eGFR was performed to assess the value of SLEEK in evaluating renal function and displaying renal artery. RESULTS: The performance of SLEEK to display renal artery was highly consistent with the results of CTA (kappa = 0.713). The corticomedullary contrast ratio positively correlated with eGFR (p = 0.004, r = 0.322) and was significantly higher in SLEEK images than in DWI images in all three groups (p < 0.001). There was no significant difference in corticomedullary contrast ratio in SLEEK images between Group 1 and Group 2 (p = 0.285). However, the minimal renal cortical thickness, which significantly correlated with eGFR (p < 0.001, r = 0.866), was significantly different between Group 1 and Group 2 (p < 0.001). ROC analysis showed good diagnostic performance when differentiating patients with eGFR> 60 from those with eGFR< 60. CONCLUSIONS: The SLEEK sequence could evaluate simultaneously renal function through corticomedullary differentiation and renal arteries, enabling one-stop assessment in hypertensive patients with suspected renal dysfunction. KEY POINTS: • Spatial labeling with multiple inversion pulses (SLEEK) improves renal corticomedullary differentiation in hypertensive patients with renal dysfunction compared with DWI. • SLEEK clearly displays renal artery in hypertensive patients with renal dysfunction. • SLEEK could be utilized as a one-stop assessment method for evaluating renal function and renal artery in hypertensive patients.


Assuntos
Nefropatias , Artéria Renal , Taxa de Filtração Glomerular , Humanos , Rim/diagnóstico por imagem , Nefropatias/complicações , Nefropatias/diagnóstico por imagem , Imageamento por Ressonância Magnética , Artéria Renal/diagnóstico por imagem , Estudos Retrospectivos
12.
Magn Reson Imaging ; 66: 176-184, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31484043

RESUMO

PURPOSE: To investigate the utility of diffusion kurtosis imaging (DKI) MRI for evaluation of renal fibrosis in rats with unilateral ureteral obstruction (UUO). METHODS: Twenty-five rats had UUO, and ten rats were subjected to sham operation as control. DKI was performed on a 3.0 T MRI scanner on days 1, 3, 5, and 7 after ligation. All rats then underwent 18F-FDG dynamic PET to evaluate unilateral renal function, followed by histological analysis to examine α-smooth muscle actin (α-SMA) expression. DKI metrics were assessed among the time points and between two sides, and compared with maximum standardized uptake value (SUVmax), serum levels of creatinine and urea, and fibrosis marker α-SMA. RESULTS: Mean kurtosis (MK) on day 7, axial kurtosis (Ka) on days 3 and 7, mean diffusivity (MD) on days 1, 3, 5, and 7, and fractional anisotropy (FA) on days 3, 5, and 7 of cortex and medulla between the UUO and contralateral sides were significantly different (all p < 0.05). Over the course of UUO progression, there were significant changes in Ka, MD and FA of medulla (all p < 0.05). FA of medulla was positively correlated with SUVmax (r = 0.641, p < 0.001), and MD of cortex was negatively correlated with urea (r = -0.534, p = 0.001). MD of cortex was negatively correlated with α-SMA on UUO sides (r = -0.710, p < 0.001). CONCLUSIONS: DKI shows the potential for noninvasive assessment of renal fibrosis and unilateral renal function induced by UUO.


Assuntos
Actinas/genética , Imagem de Tensor de Difusão/métodos , Fluordesoxiglucose F18 , Nefropatias/diagnóstico por imagem , Nefropatias/patologia , Tomografia por Emissão de Pósitrons/métodos , Obstrução Ureteral/diagnóstico por imagem , Animais , Modelos Animais de Doenças , Fibrose , Expressão Gênica/genética , Rim/diagnóstico por imagem , Rim/patologia , Nefropatias/complicações , Nefropatias/genética , Masculino , Compostos Radiofarmacêuticos , Ratos , Ratos Sprague-Dawley , Obstrução Ureteral/complicações , Obstrução Ureteral/genética , Obstrução Ureteral/patologia
13.
Cancer Manag Res ; 11: 1569-1578, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30863167

RESUMO

PURPOSE: This study aimed to investigate the clinical value of a tumor map for assessing the ablative effect after ultrasound-guided percutaneous microwave ablation (US-PMWA) for hepatocellular carcinoma (HCC). METHODS: The medical records of 68 patients (49 male and 19 female, 59.9±12.7 years) with HCC who underwent US-PMWA from May 2013 to May 2017 were reviewed. A tumor map was generated from the fusion of three-dimensional (3D) visualization images based on the preoperative target tumor and postoperative ablation area, to evaluate whether the ablation area covering the tumor has reached a 5 mm ablative margin (AM). The lesions were divided into two groups according to the tumor maps: group A (failed to achieve AM) and group B (achieved AM). The cumulative local tumor progression (LTP) rates of both groups were statistically analyzed using the log-rank test. RESULTS: Success rate of tumor map generation was 100% (68/68), and no residual tumors were found. MWA-related 3D images, which included target tumor volume, ablation area volume, and residual liver ratio, were compared between groups A and B (P=0.295, P=0.772, and P=0.527, respectively). Technique effectiveness rate (91.7% vs 100%) was achieved in the two groups, showing no significant statistical differences (P=0.672). The 3-, 6-, 9-, and 12-month LTP rate was 8.3%, 16.7%, 20.8%, and 34%, respectively, for group A and 0%, 2.8%, 2.8%, and 2.8%, respectively, for group B, showing significant statistical differences (P<0.001) between the two groups. CONCLUSION: The novel technology of tumor map generated from 3D visualization of image fusion is feasible and useful in evaluating the ablative effect of US-PMWA for HCC.

14.
Ultrasound Med Biol ; 44(9): 1986-1995, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30055820

RESUMO

The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma.


Assuntos
Técnicas de Ablação/métodos , Adenocarcinoma/cirurgia , Meios de Contraste , Eletroporação/métodos , Aumento da Imagem/métodos , Neoplasias Pancreáticas/cirurgia , Ultrassonografia/métodos , Adenocarcinoma/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Fosfolipídeos , Hexafluoreto de Enxofre , Resultado do Tratamento
15.
Med Phys ; 44(11): 5873-5888, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28857194

RESUMO

PURPOSE: In liver microwave ablation (MWA) surgery, the ablation area covers the tumor to generate tissue necrosis and treat the cancer. As the liver deforms during the operation, deviation between the target area determined during preoperative planning and the resultant ablation area is inevitable. Therefore, an accurate assessment of tumor coverage is crucial for treatment. Through registration between the pre- and postoperative livers, the ablation area is warped on the preoperative liver for the computation of tumor coverage. However, large deformations between the pre- and postoperative livers are caused by multiple factors, and these diverse deformations make registration a challenging task. The purpose of this paper was to develop an automatic method that can accurately register post- to preoperative livers. METHODS: In the proposed method, nonrigid deformations caused by respiratory movement and edema are separately considered and estimated by the local incompressible model in the registration of livers. The pre- and postoperative livers are first aligned by a rigid registration based on a convex hull. In the nonrigid registrations, local incompressible constraints are then set on the liver and the ablation area to estimate the deformations caused by respiratory movement and edema, respectively. The concatenation of the rigid and nonrigid deformations is used to warp the ablation area on the preoperative liver. RESULTS: The proposed method was evaluated using clinical CT datasets from 20 patients. The Dice similarity coefficient (DSC) between the preoperative and warped postoperative livers is 94.35%, the mean surface distance (MSD) between the livers is 1.65 mm, the mean Hausdorff distance (HDD) between the livers is 3.36 mm, and the mean corresponding distance (MCD) between the corresponding landmarks is 1.70 mm. Compared with five other state-of-the-art methods, the proposed method achieves automatic ablation assessment with highly accurate registration. CONCLUSIONS: The proposed method achieves a high accuracy for registering the livers. The sizes and positions of the ablation area and tumor are accurately compared for the assessment of ablation surgery.


Assuntos
Técnicas de Ablação , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Fígado/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas , Tomografia Computadorizada por Raios X
16.
Zhonghua Liu Xing Bing Xue Za Zhi ; 36(5): 455-9, 2015 May.
Artigo em Chinês | MEDLINE | ID: mdl-26080633

RESUMO

OBJECTIVE: To evaluate the cost-effectiveness of two-stage and three-stage hearing screenings for newborns. METHODS: Hearing screening was performed for the normal newborns born in 7 hospitals in Beijing from October 2010 to December 2012 by using two stage and three stage strategies as well as hearing diagnostic test, and the cost effectiveness evaluation of two strategies was conducted. The data about the cost of screening and diagnostic test were from the hospitals. The data about car fare and charge for loss of working time of parents were collected through questionnaire survey. The sensitivity was analyzed according to the compliance rate. RESULTS: A total of 62,695 newborns received initial hearing screening, 5,809 newborns failed, the positive rate was 9.30%. A total of 4,933 newborns received rescreening, 972 newborns failed, the positive rate was 19.70%. Among the newborns failed in rescreening, 412 were provided with hearing diagnostic test and 360 received diagnostic test. The diagnostic test indicated that the hearing of 217 newborns were abnormal (60.28%). A total of 276 newborns received the third screening, 163 newborns failed, in which 125 received diagnostic test and 112 had abnormal hearing (45 had moderate and above hearing impairment), the abnormal rate was 89.60%. The average cost for three-stage screening (37,242 yuan RMB per case) was higher than that for two-stage screening (19,985 yuan RMB per case). With the increase of compliance, the cost-effectiveness of three-stage screening increased. CONCLUSION: The cost-effectiveness of three-stage screening was influenced by screening compliance. It is recommended that three-stage screening strategy might be taken in area where the screening compliance rate is >90%.


Assuntos
Testes Auditivos/economia , Triagem Neonatal/economia , Análise Custo-Benefício , Perda Auditiva/diagnóstico , Testes Auditivos/métodos , Humanos , Recém-Nascido , Triagem Neonatal/métodos
17.
Int J Hyperthermia ; 31(1): 40-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25766386

RESUMO

OBJECTIVE: This study sought to evaluate the safety and efficacy of ultrasound-guided (US-guided) percutaneous microwave (MW) ablation combined with percutaneous ethanol injection (PEI) to treat liver tumours adjacent to the gallbladder. MATERIALS AND METHODS: A total of 136 patients with hepatocellular carcinoma (HCC) adjacent to the gallbladder, who underwent ultra-sonographically-guided percutaneous MW ablation, which was combined with PEI in 132 patients, were retrospectively assessed. The patient population characteristics, tumour features, local tumour progression and treatment were compared and analysed. The safety and efficacy of the therapy were assessed by clinical data and imaging in follow-up examinations. RESULTS: All patients were completely treated with two sessions; 120 patients underwent one session, 16 patients underwent two sessions. The primary technique was effective in 95.6% of the cases, according to the computed tomography (CT) or magnetic resonance imaging (MRI) in the one-month follow-up (132 of 138 sessions). PEI and other therapies were performed in the patients who had been incompletely treated (all six patients underwent PEI, and some underwent other therapies, including one transcatheter arterial chemoembolisation (TACE), one liver transplantation and two liver resections). There was a median follow-up period of 30.1 months and a range of 4 to 68 months. None of the patients had major complications. There were no treatment-related deaths. Twenty-six patients died of primary disease progression that was not directly attributable to MW ablation (19.1%, 26/136). Local tumour progression was noted in five patients (3.7%, 5/136), who had completely ablated tumours at follow-up. The patients with locally progressing tumours underwent additional therapy (three patients underwent PEI, one patient TACE, and one liver resection). CONCLUSION: Ultrasound-guided percutaneous MW ablation, in combination with percutaneous ethanol injection and thermal monitoring, is a safe and effective treatment for HCC adjacent to the gallbladder.


Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter , Etanol/uso terapêutico , Neoplasias Hepáticas/terapia , Micro-Ondas , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Quimioembolização Terapêutica , Terapia Combinada , Feminino , Vesícula Biliar , Humanos , Injeções , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Chin Med J (Engl) ; 125(5): 851-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22490586

RESUMO

BACKGROUND: Various methods can be applied to build predictive models for the clinical data with binary outcome variable. This research aims to explore the process of constructing common predictive models, Logistic regression (LR), decision tree (DT) and multilayer perceptron (MLP), as well as focus on specific details when applying the methods mentioned above: what preconditions should be satisfied, how to set parameters of the model, how to screen variables and build accuracy models quickly and efficiently, and how to assess the generalization ability (that is, prediction performance) reliably by Monte Carlo method in the case of small sample size. METHODS: All the 274 patients (include 137 type 2 diabetes mellitus with diabetic peripheral neuropathy and 137 type 2 diabetes mellitus without diabetic peripheral neuropathy) from the Metabolic Disease Hospital in Tianjin participated in the study. There were 30 variables such as sex, age, glycosylated hemoglobin, etc. On account of small sample size, the classification and regression tree (CART) with the chi-squared automatic interaction detector tree (CHAID) were combined by means of the 100 times 5-7 fold stratified cross-validation to build DT. The MLP was constructed by Schwarz Bayes Criterion to choose the number of hidden layers and hidden layer units, alone with levenberg-marquardt (L-M) optimization algorithm, weight decay and preliminary training method. Subsequently, LR was applied by the best subset method with the Akaike Information Criterion (AIC) to make the best used of information and avoid overfitting. Eventually, a 10 to 100 times 3-10 fold stratified cross-validation method was used to compare the generalization ability of DT, MLP and LR in view of the areas under the receiver operating characteristic (ROC) curves (AUC). RESULTS: The AUC of DT, MLP and LR were 0.8863, 0.8536 and 0.8802, respectively. As the larger the AUC of a specific prediction model is, the higher diagnostic ability presents, MLP performed optimally, and then followed by LR and DT in terms of 10-100 times 2-10 fold stratified cross-validation in our study. Neural network model is a preferred option for the data. However, the best subset of multiple LR would be a better choice in view of efficiency and accuracy. CONCLUSION: When dealing with data from small size sample, multiple independent variables and a dichotomous outcome variable, more strategies and statistical techniques (such as AIC criteria, L-M optimization algorithm, the best subset, etc.) should be considered to build a forecast model and some available methods (such as cross-validation, AUC, etc.) could be used for evaluation.


Assuntos
Árvores de Decisões , Diabetes Mellitus Tipo 2/complicações , Neuropatias Diabéticas/diagnóstico , Modelos Logísticos , Estudos de Casos e Controles , Neuropatias Diabéticas/etiologia , Humanos
19.
Am J Hematol ; 87(5): 541-4, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22460248

RESUMO

A few warfarin pharmacogenetic dosing algorithms have been proposed,based on multiethnic or homogeneous populations, to estimate warfarin therapeutic doses. However, it remains to be proven that which algorithm is accurate in predicting warfarin dose in Chinese people. We selected eight warfarin dose predictive pharmacogenetic algorithms and retrospectively assessed the predictive accuracy of each algorithm in a total of 368 eligible outpatients by comparing the actual stable therapeutic dose to the dose predicted by the algorithm. Our results showed that a high level of performance was demonstrated by three algorithms,Gage et al., Anderson et al., and Wu et al., having a similar performance in coefficient of determination (R2) and percentage of patients predicted dose within 20% of actual dose. The Gage et al. algorithm had the lowest mean absolute error (MAE). These results indicated that the algorithm by Gage et al. provided a more accurate prediction than did the others,which suggests that this pharmacogenetic algorithm might be used in clinical practice to guide rational administration of warfarin.


Assuntos
Algoritmos , Anticoagulantes/administração & dosagem , Hidrocarboneto de Aril Hidroxilases/genética , Povo Asiático/genética , Etnicidade/genética , Oxigenases de Função Mista/genética , Varfarina/administração & dosagem , Adolescente , Adulto , Idoso , Alelos , Anticoagulantes/farmacocinética , Biotransformação/genética , China/epidemiologia , Citocromo P-450 CYP2C9 , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Trombofilia/tratamento farmacológico , Trombofilia/etnologia , Trombofilia/genética , Vitamina K Epóxido Redutases , Varfarina/farmacocinética , Adulto Jovem
20.
World J Gastroenterol ; 14(24): 3908-13, 2008 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-18609718

RESUMO

AIM: To evaluate the feasibility and efficacy of percutaneous transhepatic lymphosonography (PTL) as a novel method for the detection of tumor lymphangiogenesis in hepatic VX(2) of rabbits and to evaluate combined PTL and routine contrast-enhanced ultrasonographic imaging for the diagnosis of liver cancer. METHODS: Ten rabbits with VX(2) tumor were included in this study. SonoVue (0.1 mL/kg) was injected into each rabbit via an ear vein for contrast-enhanced ultrasonographic imaging, and 0.5 mL SonoVue was injected into the normal liver parenchyma near the VX(2) tumor for PTL. Images and/or movie clips were stored for further analysis. RESULTS: Ultrasonographic imaging showed VX(2) tumors ranging 5-19 mm in the liver of rabbits. The VX(2) tumor was hyperechoic and hypoechoic to liver parenchyma at the early and later phase, respectively. The hepatic lymph vessels were visualized immediately after injection of contrast medium and continuously visualized with SonoVue during PTL. The boundaries of VX(2) tumors were hyperechoic to liver parenchyma and the tumors. There was a significant difference in the values for the boundaries of VX(2) tumors after injection compared with the liver normal parenchyma and the tumor parenchyma during PTL. CONCLUSION: PTL is a novel method for the detection of tumor lymphangiogenesis in hepatic VX(2) of rabbits. Combined PTL and contrast-enhanced ultrasonographic imaging can improve the diagnosis of liver cancer.


Assuntos
Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Linfangiogênese , Vasos Linfáticos/diagnóstico por imagem , Masculino , Microbolhas , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA