Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Regul Toxicol Pharmacol ; 65(3): 344-65, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23246604

RESUMO

Assessing chemicals for acute oral toxicity is a standard information requirement of regulatory testing. However, animal testing is now prohibited in the cosmetics sector in Europe, and strongly discouraged for industrial chemicals. Building on the results of a previous international validation study, a follow up study was organised to assess if the 3T3 Neutral Red Uptake cytotoxicity assay could identify substances not requiring classification as acute oral toxicants under the EU regulations. Fifty-six coded industrial chemicals were tested in three laboratories, each using one of the following protocols: the previously validated protocol, an abbreviated version of the protocol and the protocol adapted for an automation platform. Predictions were very similar among the three laboratories. The assay exhibited high sensitivity (92-96%) but relatively low specificity (40-44%). Three chemicals were under predicted. Assuming that most industrial chemicals are not likely to be acutely toxic, this test method could prove a valuable component of an integrated testing strategy, a read-across argument, or weight-of-evidence approach to identify non toxic chemicals (LD50>2000 mg/kg). However, it is likely to under predict chemicals acting via specific mechanisms of action not captured by the 3T3 test system, or which first require biotransformation in vivo.


Assuntos
Alternativas aos Testes com Animais , Fibroblastos/efeitos dos fármacos , Testes de Toxicidade/métodos , Xenobióticos/toxicidade , Animais , Células 3T3 BALB , Sobrevivência Celular/efeitos dos fármacos , Corantes/metabolismo , Fibroblastos/metabolismo , Fibroblastos/patologia , Camundongos , Vermelho Neutro/metabolismo , Valor Preditivo dos Testes
2.
Regul Toxicol Pharmacol ; 63(3): 480-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22687423

RESUMO

This is the report from the "ECVAM-EFPIA workshop on 3T3 NRU Phototoxicity Test: Practical Experience and Implications for Phototoxicity Testing", jointly organized by ECVAM and EFPIA and held on the 25-27 October 2010 in Somma Lombardo, Italy. The European Centre for the Validation of Alternative Methods (ECVAM) was established in 1991 within the European Commission Joint Research, based on a Communication from the European Commission (1991). The main objective of ECVAM is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine and replace the use of laboratory animals. The European Federation of Pharmaceuticals Industries and Association (EFPIA) represent the pharmaceutical industry operating in Europe. Through its direct membership of 31 national associations and 40 leading pharmaceutical companies, EFPIA is the voice on the EU scene of 2200 companies committed to researching, developing and bringing to patients new medicines that improve health and the quality of life around the world. The workshop, co-chaired by Joachim Kreysa (ECVAM) and Phil Wilcox (GSK, EFPIA) involved thirty-five experts from academia, regulatory authorities and industry, invited to contribute with their experiences in the field of phototoxicology. The main objectives of the workshop were: -to present 'in use' experience of the pharmaceutical industry with the 3T3 Neutral Red Uptake Phototoxicity Test (3T3 NRU-PT), -to discuss why it differs from the results in the original validation exercise, -to discuss technical issues and consider ways to improve the usability of the 3T3 NRU-PT for (non-topical) pharmaceuticals, e.g., by modifying the threshold of chemical light absorption to trigger photo-toxicological testing, and by modifying technical aspects of the assay, or adjusting the criteria used to classify a positive response. During the workshop, the assay methodology was reviewed by comparing the OECD Test Guideline (TG 432) with the protocols used in testing laboratories, data from EFPIA and JPMA 'surveys' were presented and possible reasons for the outcomes were discussed. Experts from cosmetics and pharmaceutical industries reported on their experience with the 3T3 NRU-PT and evidence was presented for phototoxic clinical symptoms that could be linked to certain relevant molecules. Brainstorming sessions discussed if the 3T3 NRU-PT needed to be improved and whether alternatives to the 3T3 NRU-PT exist. Finally, the viewpoint from EU and US regulators was presented. In the final session, the conclusions of the meeting were summarized, with action points. It was concluded that the 3T3 NRU-PT identifies phototoxicological hazards with a 100% sensitivity, and thus is accepted as the tier one test that correctly identifies the absence of phototoxic potential. Consequently, positive results in the 3T3 NRU-PT often do not translate into a clinical phototoxicity risk. Possible ways to improve the practical use of this assay include: (i) adaptation of changed UV/vis-absorption criteria as a means to reduce the number of materials tested, (ii) reduction of the highest concentration to be tested, and (iii) consideration of modifying the threshold criteria for the prediction of a positive call in the test.


Assuntos
Alternativas aos Testes com Animais/métodos , Dermatite Fototóxica , Vermelho Neutro/metabolismo , Fármacos Fotossensibilizantes/toxicidade , Testes de Toxicidade/métodos , Células 3T3 , Animais , Bioensaio/métodos , Qualidade de Produtos para o Consumidor , Cosméticos/toxicidade , Dermatite Fototóxica/etiologia , Indústria Farmacêutica , Camundongos , Espécies Reativas de Oxigênio/metabolismo
3.
Regul Toxicol Pharmacol ; 62(2): 393-403, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22085589

RESUMO

Validated in vitro methods for skin corrosion and irritation were adopted by the OECD and by the European Union during the last decade. In the EU, Switzerland and countries adopting the EU legislation, these assays may allow the full replacement of animal testing for identifying and classifying compounds as skin corrosives, skin irritants, and non irritants. In order to develop harmonised recommendations on the use of in vitro data for regulatory assessment purposes within the European framework, a workshop was organized by the Swiss Federal Office of Public Health together with ECVAM and the BfR. It comprised stakeholders from various European countries involved in the process from in vitro testing to the regulatory assessment of in vitro data. Discussions addressed the following questions: (1) the information requirements considered useful for regulatory assessment; (2) the applicability of in vitro skin corrosion data to assign the corrosive subcategories as implemented by the EU Classification, Labelling and Packaging Regulation; (3) the applicability of testing strategies for determining skin corrosion and irritation hazards; and (4) the applicability of the adopted in vitro assays to test mixtures, preparations and dilutions. Overall, a number of agreements and recommendations were achieved in order to clarify and facilitate the assessment and use of in vitro data from regulatory accepted methods, and ultimately help regulators and scientists facing with the new in vitro approaches to evaluate skin irritation and corrosion hazards and risks without animal data.


Assuntos
Cáusticos/toxicidade , Irritantes/toxicidade , Medição de Risco/legislação & jurisprudência , Pele/efeitos dos fármacos , Alternativas aos Testes com Animais , Animais , União Europeia , Feminino , Masculino , Suíça
4.
Exp Toxicol Pathol ; 60(2-3): 225-33, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18440212

RESUMO

A short description of the history of the 3Rs concept is given, which was developed as the scientific concept to refine, reduce and replace animal experiments by Russel and Burch more than 40 years ago. In addition, the legal framework in Europe for developing alternatives to animal experiments is given and the current status of in vitro systems in pharmacology and toxicology is described including an update on metabolising systems. The decrease in experimental animal numbers during the past decade in Europe is illustrated by the situation in Germany and the contribution of international harmonisation of test guidelines on reducing animal numbers in regulatory testing is described. A review of the development of the principles of experimental validation is given and the 3T3 NRU in vitro phototoxicity test is used as an example for a successful validation study, which led to the acceptance of the first in vitro toxicity test for regulatory purposes by the OECD. Finally, the currently accepted alternative methods for standardisation and safety testing of drugs, biologicals and medical devices are summarised.


Assuntos
Alternativas aos Testes com Animais/legislação & jurisprudência , Técnicas de Cultura de Células , Testes de Toxicidade/métodos , Animais , União Europeia , Alemanha , Guias como Assunto , Humanos , Cooperação Internacional , Medição de Risco
5.
Altern Lab Anim ; 34(4): 393-406, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16945007

RESUMO

Currently, two reconstructed human skin models, EpiDerm and EPISKIN are being evaluated in an ECVAM skin irritation validation study. A common skin irritation protocol has been developed, differing only in minor technical details for the two models. A small-scale study, applying this common skin irritation protocol to the SkinEthic reconstructed human epidermis (RHE), was performed at ZEBET at the BfR, Berlin, Germany, to consider whether this protocol could be successfully transferred to another epidermal model. Twenty substances from Phase III of the ECVAM prevalidation study on skin irritation were tested with the SkinEthic RHE. After minor, model-specific adaptations for the SkinEthic RHE, almost identical results to those obtained with the EpiDerm and EPISKIN models were achieved. The overall accuracy of the method was more than 80%, indicating a reliable prediction of the skin irritation potential of the tested chemicals when compared to in vivo rabbit data. As a next step, inter laboratory reproducibility was assessed in a study conducted between ZEBET and the Department of Experimental Toxicology, Schering AG, Berlin, Germany. Six coded substances were tested in both laboratories, with three different batches of the SkinEthic model. The assay results showed good reproducibility and correct predictions of the skin irritation potential for all six test chemicals. The results obtained with the SkinEthic RHE and the common protocol were reproducible in both phases, and the overall outcome is very similar to that of earlier studies with the EPISKIN and EpiDerm models. Therefore, the SkinEthic skin irritation assay test protocol can now be evaluated in a formal "catch-up" validation study.


Assuntos
Epiderme/efeitos dos fármacos , Substâncias Perigosas/toxicidade , Irritantes/toxicidade , Testes de Toxicidade/métodos , Células Cultivadas , Estudos de Avaliação como Assunto , Substâncias Perigosas/classificação , Humanos , Irritantes/classificação
6.
Toxicol In Vitro ; 20(5): 547-59, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16455230

RESUMO

Based on two successfully completed ECVAM validation studies for in vitro skin corrosion testing of chemicals, the National Co-ordinators of OECD Test Guideline Programme endorsed in 2002 two new test guidelines: TG 430 'Transcutaneous Electrical Resistance assay' and TG 431 'Human Skin Model Test'. To allow all suitable in vitro human reconstructed (dermal or epidermal) models to be used for skin corrosion testing, the OECD TG 431 defines general and functional conditions that the model must meet before it will be routinely used for skin corrosion testing. In addition, the guideline requires correct prediction of 12 reference chemicals and assessment of intra- and inter-laboratory variability. To show that the OECD TG 431 concept works, in 2003 ZEBET tested several chemicals from the ECVAM validation trials on the SkinEthic reconstituted human epidermal (RHE) model. Based on knowledge that reconstructed human skin models perform similarly in toxicological studies, it was decided to adopt the validated EpiDerm skin corrosion test protocol and prediction model to the SkinEthic model. After minor technical changes, classifications were obtained in concordance with those reported for the validated human skin models EPISKIN and EpiDerm. To allow adequate determination of inter-laboratory reproducibility, a blind trial was conducted in three laboratories -- ZEBET (D), Safepharm (UK) and BASF (D), in which the 12 endorsed reference chemicals were tested. Results obtained with the SkinEthic epidermal model were reproducible, both within and between laboratories, and over time. Concordance between the in vitro predictions of skin corrosivity potential obtained with the SkinEthic model and the predictions obtained with the accepted tests of OECD TG 430 and TG 431 was very good. The new test was able to distinguish between corrosive and non-corrosive reference chemicals with an accuracy of 93%.


Assuntos
Cáusticos/toxicidade , Epiderme/efeitos dos fármacos , Cáusticos/classificação , Corrosão , Impedância Elétrica , Humanos , Técnicas In Vitro , Reprodutibilidade dos Testes , Testes de Toxicidade
7.
Altern Lab Anim ; 33(4): 351-67, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16185104

RESUMO

During the past decade, several validation studies have been conducted on in vitro methods for discriminating between skin irritating and non-irritating chemicals. The reconstructed human skin models, EpiDerm and EPISKIN, provided the most promising results. Based on experience of the similar performance of the two skin models, it was suggested that a common test protocol and prediction model should be developed for the prediction of skin irritation potential with the two models. When the EPISKIN protocol was applied with the EpiDerm model, an acceptable specificity (80%) was achieved, whereas the sensitivity (60%) was low. In 2003, the EPISKIN protocol was further refined by extending the post-incubation period following exposure to test chemicals. This extension and additional technical improvements to the EpiDerm protocol were evaluated with 19 chemicals from the prevalidation study. With the new test design, high sensitivity (80%) and specificity (78%) were obtained. The statistical probability for correct classifications was high, so the test was considered to be ready for formal validation. However, since test optimisation had been conducted with the same test chemicals as were used in the ECVAM prevalidation study, it was decided that the optimisation of the protocol had to be verified with a new set of chemicals. Thus, in the current study, 26 additional chemicals (10 rabbit irritants and 16 non-irritants), which had previously been selected and tested by LOREAL with EPISKIN, were evaluated in three independent experiments with EpiDerm. With this unbalanced testing set, a specificity of 94%, and a sensitivity of 60% were obtained, while the positive and negative predictivity and accuracy remained almost unchanged (around 80%) in comparison to the in vivo rabbit data. Overall, 45 chemicals (20 irritants and 25 non-irritants) were tested according to the final protocol. The resulting high positive (82%) and negative predictive values (79%) confirmed the reliability (accuracy of 80%) of the improved test protocol of the EpiDerm model.


Assuntos
Alternativas aos Testes com Animais , Irritantes/toxicidade , Testes de Irritação da Pele , Pele/efeitos dos fármacos , Humanos , Técnicas In Vitro , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Pele/metabolismo
8.
Altern Lab Anim ; 33(3): 215-37, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16180977

RESUMO

Huggins has reported on the current situation relating to the development of alternatives to the Draize eye irritation test with rabbits, and an ECVAM Working Group have reviewed the efforts needed in order to replace this animal test within the next 10 years by using the results of non-animal assessment methods. Our report reviews regulatory experience gained over the last 20 years with the EU chemicals notification procedure with respect to the assessment of eye lesions observed in Draize tests. The nature of eye lesions and their importance for classification and labelling of possible hazards to human eyes are evaluated and discussed, with a view to promoting the development of specific in vitro assays which are able to discriminate between eye damage, moderate eye irritation, and minor irritation effects which are completely reversible within a few days. Structural alerts for the prediction of eye irritation/corrosion hazards to be classified and labelled according to international classification criteria, are presented, which should be validated in accordance with internationally agreed (OECD) principles for (Q)SAR system validation. Physicochemical limit values for prediction of the absence of any eye irritation potential relevant for human health can make available a definition of the applicability domains of alternative methods developed for the replacement of the Draize eye irritation test.


Assuntos
Alternativas aos Testes com Animais , Traumatismos Oculares/induzido quimicamente , Irritantes/toxicidade , Relação Quantitativa Estrutura-Atividade , Testes de Toxicidade/métodos , Xenobióticos/toxicidade , Animais , Olho/efeitos dos fármacos , Olho/patologia , Traumatismos Oculares/patologia , Humanos , Técnicas In Vitro , Irritantes/química , Irritantes/classificação , Coelhos , Reprodutibilidade dos Testes , Xenobióticos/química , Xenobióticos/classificação
9.
Arch Toxicol ; 78(10): 549-64, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15170526

RESUMO

During the past 20 years the EU legislation for the notification of chemicals has focussed on new chemicals and at the same time failed to cover the evaluation of existing chemicals in Europe. Therefore, in a new EU chemicals policy (REACH, Registration, Evaluation and Authorization of Chemicals) the European Commission proposes to evaluate 30,000 chemicals within a period of 15 years. We are providing estimates of the testing requirements based on our personal experiences during the past 20 years. A realistic scenario based on an in-depth discussion of potential toxicological developments and an optimised "tailor-made" testing strategy shows that to meet the goals of the REACH policy, animal numbers may be significantly reduced below 10 million if industry would use in-house data from toxicity testing, which are confidential, if non-animal tests would be used, and if information from quantitative structure activity relationships (QSARs) would be applied in substance-tailored testing schemes. The procedures for evaluating the reproductive toxicity of chemicals have the strongest impact on the total number of animals bred for testing under REACH. We are assuming both an active collaboration with our colleagues in industry and substantial funding of the development and validation of advanced non-animal methods by the EU Commission, specifically in reproductive and developmental toxicity.


Assuntos
Alternativas aos Testes com Animais/legislação & jurisprudência , Alternativas aos Testes com Animais/métodos , Substâncias Perigosas/toxicidade , Agências Internacionais/legislação & jurisprudência , Medição de Risco , Testes de Toxicidade , Animais , União Europeia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA