Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Cardiol ; 403: 131895, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38395260

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) is increasingly being used in the preoperative workup for liver transplantation (LT). We sought to assess the utility of integrating CCTA with the novel CAD-LT (Coronary Artery Disease in Liver Transplantation) score and its impact on reducing the need for invasive coronary angiography prior to LT. METHODS: We conducted a retrospective cohort study of consecutive patients (age ≥ 18 years) who underwent CCTA for LT workup between 2011 and 2018 at the Victorian Liver Transplant Unit, Melbourne, Australia. CAD-LT scores, a traditional risk factor-based criteria, were calculated, and patients stratified as low-, intermediate- or high-risk. RESULTS: Overall, 229 patients underwent CCTA. The mean age was 66 ± 5 years (82% male) with a modest-to-high risk factor burden (diabetes, 53%; hypertension, 46%; current or former smoker, 62%). The mean CAD-LT score of our cohort was 12.4 ± 4.0. No patients were classified as low-risk, 49 patients (21.4%) were deemed intermediate-risk and 180 patients (78.6%) were deemed high-risk. A high CAD-LT score (≥ 9) showed high sensitivity (95.3% [95% CI 86-98%]) and modest specificity (27.8% [95% CI 21-35%]) for the detection of obstructive coronary artery disease on CCTA, with a negative predictive value of 94%. Following multidisciplinary discussions, only 41 patients (18%) of patients proceeded to ICA of which 27% received percutaneous coronary intervention. CONCLUSIONS: The use of CCTA in patients deemed intermediate- to high-risk by the CAD-LT score has the potential to reduce the need for invasive coronary angiography in patients undergoing LT workup.


Assuntos
Doença da Artéria Coronariana , Transplante de Fígado , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Adolescente , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Medição de Risco/métodos , Angiografia Coronária/métodos , Valor Preditivo dos Testes
2.
J Diabetes Complications ; 36(1): 108076, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34802902

RESUMO

AIMS: To compare levels of renal hypoxia measured by Blood Oxygen Level Dependent (BOLD) magnetic resonance imaging (MRI) with measured transverse relaxation rate (R2*) and renal structural changes including apparent diffusion coefficient (ADC) and fractional anisotropy (FA) in patients with type 1 diabetes and healthy controls. METHODS: Cohort study comparing MRI metrics in type 1 diabetes (n = 32, GFR 105 (77, 120) ml/min.1.73m2) and controls (n = 10). Renal function and selected inflammatory renal biomarkers were also measured. RESULTS: For BOLD, we found reduced cortical [14.7 (13.7,15.8) (1/s) vs 15.7 (15.1,16.6) (1/s), p < 0.001] and medullary [24.8 (21.8,28.2) (1/s) vs. 29.3 (24.3,32.4) (1/s), p < 0.001] R2*, indicating more oxygenated parenchyma, in type 1 diabetes vs. controls, respectively. We observed reduced cortical FA, indicating decreased structural integrity in type 1 diabetes -0.04 (-0.07, -0.01), (p = 0.02). We found reduced cortical ADC, reflecting reduced water diffusion, in non-hyperfiltering [2.40 (2.29,2.53) (103mm2/s)] versus hyperfiltering [2.61 (2.53,2.74) (103mm2/s)] type 1 diabetes patients. MRI parameters correlated with renal function and inflammatory renal biomarkers. CONCLUSIONS: MRI derived indices of renal function and structure differed between (i) type 1 diabetes and healthy controls, and (ii) between non-hyperfiltering and hyperfiltering type 1 diabetes patients, providing insight into the role of hypoxia and renal structural, and functional changes in DKD.


Assuntos
Diabetes Mellitus Tipo 1 , Nefropatias Diabéticas , Estudos de Coortes , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico por imagem , Nefropatias Diabéticas/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
3.
Neurosurgery ; 87(3): 453-465, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32140714

RESUMO

Treatment of unruptured intracranial aneurysms can reduce the risk of subarachnoid hemorrhage and its associated morbidity and mortality. However, current methods to predict the risk of rupture and optimize treatment strategies for intracranial aneurysms are limited. Assessment of intra-aneurysmal flow using 4-dimensional magnetic resonance imaging (4D MRI) is a novel tool that could be used to guide therapy. A systematic search of the literature was performed to provide a state-of-the-art review on 4D MRI assessment of unruptured intracranial aneurysms. A total of 18 studies were available for review. Eccentric flow on 4D MRI is associated with a greater aspect ratio and peak wall shear stress (WSS). WSS, vorticity, and peak velocity are greater in saccular than fusiform aneurysms. Unstable aneurysms are associated with greater WSS, peak wall stress, and flow jet angle and may exhibit wall enhancement. In comparison to computational fluid dynamics (CFD), 4D MRI has a lower spatial resolution and reports lower WSS and velocity magnitudes, but these parameters equalize when spatial resolution is matched. 4D MRI demonstrates the intra-aneurysmal hemodynamic changes associated with flow diversion, including significantly decreased flow velocity. Thus, 4D MRI is a novel, noninvasive imaging tool used for the evaluation of hemodynamics within intracranial aneurysms. Hemodynamic indices derived from 4D MRI appear to correlate well with the simulated (CFD) values and may be used to measure the success of endovascular therapies and risk factors for aneurysm growth and rupture.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Humanos
4.
J Med Imaging Radiat Oncol ; 64(1): 35-43, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32043319

RESUMO

INTRODUCTION: Diabetic patients with peripheral arterial disease (PAD) are challenging to assess. Non-contrast magnetic resonance angiography (MRA) offers a safe alternative in patients with renal impairment. The study objective is to evaluate accuracy of lower limb quiescent-interval single-shot (QISS) MRA and pedal QISS-arterial spin-labelled (ASL) MRA for detection of significant stenosis in diabetic patients with PAD. METHODS: Combined QISS and QISS-ASL MRA was performed in 32 diabetic PAD patients (20 male, 12 female; mean 69 years; 8 with critical ischaemia). Two readers assessed haemodynamically significant (>50%) stenosis and diagnostic confidence on MRA, against digital subtraction angiography (DSA) as the reference standard, with subgroup analysis of patients with severe renal impairment (n = 7). Inter-reader agreement of stenosis and diagnostic confidence were evaluated. Test-retest reproducibility was evaluated in 10 subjects who underwent repeat MRA on a different day. RESULTS: At DSA, 262/645 segments (40.6%) had haemodynamically significant stenoses. MRA accuracy was 78.1% (478/612) and 75.6% (464/614), sensitivity 64.7% (161/249) and 77.5% (193/249), and specificity 87.3% (317/363) and 74.2% (271/365) for 2 readers. MRA accuracy was 80.9% and 80.7% for readers 1 and 2, respectively, in patients with severe renal impairment. QISS MRA but not pedal QISS-ASL MRA was considered of diagnostic image quality. Inter-reader agreement was moderate for stenosis (ĸ = 0.60) and diagnostic confidence (ĸ = 0.41). Test-retest reproducibility was high (ĸ = 0.87) and moderate (ĸ = 0.54) for individual readers. CONCLUSIONS: Quiescent-interval single-shot MRA has reasonable accuracy in a diabetic PAD population with high burden of disease, providing a non-contrast option in patients with renal impairment. QISS-ASL MRA requires further optimisation to be clinically feasible.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/complicações , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
5.
J Comput Assist Tomogr ; 41(2): 327-333, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27753721

RESUMO

OBJECTIVE: The aim of this study was to evaluate image quality and accuracy of 64+ detector multidetector computed tomography angiography (MDCTA) for hemodynamically significant (≥50%) stenosis in patients with symptomatic peripheral arterial disease (PAD) using digital subtraction angiography as the reference standard. METHODS: This is a retrospective study of 29 patients with PAD (19 men, 10 women) who underwent lower limb MDCTA (64- or 80-detector) and digital subtraction angiography. Image quality and accuracy of MDCTA for hemodynamically significant stenosis were assessed in the infrarenal aorta and 15 lower extremity segments. RESULTS: Four hundred fifty-three segments were adequately visualized at both modalities. Multidetector CTA had 84.8% sensitivity, 87.7% specificity, and 86.3% accuracy for significant stenosis. Accuracy was decreased in the calf when compromising arterial wall calcifications were present versus absent (55.9% vs 82.4%, P < 0.0001). CONCLUSIONS: 64+ MDCTA is accurate in patients with symptomatic PAD. However, diagnostic accuracy in below-knee vessels remains relatively poorer. Alternative imaging modalities should be considered where below-knee disease is suspected.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Multidetectores/métodos , Doença Arterial Periférica/diagnóstico por imagem , Atenção Terciária à Saúde , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/métodos , Feminino , Humanos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Invest Radiol ; 47(12): 717-24, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23070094

RESUMO

OBJECTIVE: The purpose of this study was to monitor iron clearance from the liver by means of T2 and T2* mapping after administration of an ultrasmall superparamagnetic iron oxide (USPIO) agent. MATERIALS AND METHODS: The study was performed using ferumoxytol (Feraheme), a USPIO agent that has been approved by the US Food and Drug Administration for the treatment of iron deficiency anemia in adult patients with chronic kidney disease. Six healthy human participants without anemia or preexisting iron overload were prospectively included. The cohort comprised 4 men and 2 postmenopausal women, aged 22 to 57 years. T2 and T2* mapping of the liver were performed at 1.5 T using multiple spin echo and multiple gradient echo sequences, respectively. After baseline imaging, ferumoxytol was injected intravenously at a dose of 5 mg Fe/kg body weight. Imaging was repeated at 3 days, 1 month, and every 2 months thereafter for up to 11 months or until liver T2* had recovered to 24 milliseconds, the threshold used to define iron deposition. For each examination, maps of the relaxation rates R2 (= 1/T2) and R2* (= 1/T2*) were generated by fitting the signal intensity data as a function of echo time to a monoexponential decay. RESULTS: No adverse reactions to ferumoxytol injection occurred. The magnetic resonance (MR) responses to ferumoxytol varied widely among the participants. Liver R2* increased from a mean value of 35.6 s (range, 28.7-40.9 s) at baseline to a mean value of 241 s (range, 161-417 s) 3 days after administration. Liver R2 increased from 19.4 s (range, 16.6-23.8 s) at baseline to 45.3 s (range, 34.4-58.5 s) at 3 days. There was also a large variation in iron clearance times. In 1 participant, MR relaxation rates had recovered to baseline by 3 months, whereas, in 3 participants, liver R2* remained elevated at 11 months (R2* > 55 s, ie, T2* < 18 milliseconds). In these 3 participants, liver R2 also remained marginally higher at 11 months than corresponding baseline values. CONCLUSIONS: Iron deposition in the liver after a 5 mg Fe/kg dose of ferumoxytol may alter signal contrast on MR images for several months after administration. This is an important consideration in the use of USPIO agents for diagnostic purposes.


Assuntos
Meios de Contraste , Dextranos , Ferro/farmacocinética , Fígado/metabolismo , Imageamento por Ressonância Magnética , Nanopartículas de Magnetita , Adulto , Feminino , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
7.
J Magn Reson Imaging ; 33(6): 1430-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21591013

RESUMO

PURPOSE: To develop a noncontrast magnetic resonance angiography (MRA) method for comprehensive evaluation of abdominopelvic arteries in a single 3D acquisition. MATERIALS AND METHODS: A noncontrast MRA (NC MRA) pulse sequence was developed using four inversion-recovery (IR) pulses and 3D balanced steady-state free precession (b-SSFP) readout to provide arterial imaging from renal to external iliac arteries. Respiratory triggered, high spatial resolution (1.3 × 1.3 × 1.7 mm(3)) noncontrast angiograms were obtained in seven volunteers and ten patients referred for gadolinium-enhanced MRA (CE MRA). Images were assessed for diagnostic quality by two radiologists. Quantitative measurements of arterial signal contrast were also performed. RESULTS: NC MRA imaging was successfully completed in all subjects in 7.0 ± 2.3 minutes. In controls, image quality of NC MRA averaged 2.79 ± 0.39 on a scale of 0-3, where 3 is maximum. Image quality of NC MRA (2.65 ± 0.41) was comparable to that of CE MRA (2.9 ± 0.32) in all patients. Contrast ratio measurements in patients demonstrated that NC MRA provides arterial contrast comparable to source CE MRA images with adequate venous and excellent background tissue suppression. CONCLUSION: The proposed noncontrast MRA pulse sequence provides high-quality visualization of abdominopelvic arteries within clinically feasible scan times.


Assuntos
Artérias/patologia , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Gadolínio/farmacologia , Humanos , Artéria Ilíaca/patologia , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Artéria Renal/patologia , Reprodutibilidade dos Testes
8.
Am J Physiol Renal Physiol ; 296(4): F884-91, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19158343

RESUMO

This study aims to assess the feasibility of a protocol to diagnose renovascular disease using dual MR renography acquisitions: before and after administration of angiotensin-converting enzyme inhibitor (ACEi). Results of our simulation study aimed at testing the reproducibility of glomerular filtration rate (GFR) and renal plasma flow demonstrate that for a fixed overall dose of 12 ml gadolinium-based contrast material (500 mmol/l), the second dose should be approximately twice as large as the first dose. A three-compartment model for analyzing the second-injection data was shown to appropriately handle the tracer residue from the first injection. The optimized protocol was applied to 18 hypertensive patients without renovascular disease, showing minimal systematic difference in GFR measurements before and after ACEi of 0.8 +/- 4.4 ml/min or 2.7 +/- 14.9%. For 10 kidneys with significant renal artery stenosis, GFR decreased significantly after ACEi (P < 0.001, T value = 3.79), and the difference in GFR measurements before and after ACEi averaged 8.3 +/- 6.9 ml/min or 26.2 +/- 43.9%. Dual-injection MRI with optimized dose distribution appears promising for ACEi renography by offering measures of GFR changes with clinically acceptable precision and accuracy.


Assuntos
Inibidores da Enzima Conversora de Angiotensina , Enalapril , Taxa de Filtração Glomerular , Hipertensão Renovascular/diagnóstico , Angiografia por Ressonância Magnética , Modelos Biológicos , Renografia por Radioisótopo/métodos , Obstrução da Artéria Renal/diagnóstico , Fluxo Plasmático Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Simulação por Computador , Meios de Contraste , Enalapril/administração & dosagem , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/fisiopatologia , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Valor Preditivo dos Testes , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/fisiopatologia , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA