Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JMIR Rehabil Assist Technol ; 8(4): e24950, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34779789

RESUMO

BACKGROUND: Accurately measuring postural sway is an important part of balance assessment and rehabilitation. Although force plates give accurate measurements, their costs and space requirements make their use impractical in many situations. OBJECTIVE: The work presented in this paper aimed to address this issue by validating a virtual reality (VR) headset as a relatively low-cost alternative to force plates for postural sway measurement. The HTC Vive (HTC Corporation) VR headset has built-in sensors that allow for position and orientation tracking, making it a potentially effective tool for balance assessments. METHODS: Participants in this study were asked to stand upright on a force plate (NeuroCom; Natus Medical Incorporated) while wearing the HTC Vive. Position data were collected from the headset and force plate simultaneously as participants experienced a custom-built VR environment that covered their entire field of view. The intraclass correlation coefficient (ICC) was used to examine the test-retest reliability of the postural control variables, which included the normalized path length, root mean square (RMS), and peak-to-peak (P2P) value. These were computed from the VR position output data and the center of pressure (COP) data from the force plate. Linear regression was used to investigate the correlations between the VR and force plate measurements. RESULTS: Our results showed that the test-retest reliability of the RMS and P2P value of VR headset outputs (ICC: range 0.285-0.636) was similar to that of the RMS and P2P value of COP outputs (ICC: range 0.228-0.759). The linear regression between VR and COP measures showed significant correlations in RMSs and P2P values. CONCLUSIONS: Based on our results, the VR headset has the potential to be used for postural control measurements. However, the further development of software and testing protocols for balance assessments is needed.

2.
Neurology ; 80(11 Suppl 3): S25-31, 2013 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-23479540

RESUMO

OBJECTIVE: Development of an easy to administer, low-cost test of vestibular function. METHODS: Members of the NIH Toolbox Sensory Domain Vestibular, Vision, and Motor subdomain teams collaborated to identify 2 tests: 1) Dynamic Visual Acuity (DVA), and 2) the Balance Accelerometry Measure (BAM). Extensive work was completed to identify and develop appropriate software and hardware. More than 300 subjects between the ages of 3 and 85 years, with and without vestibular dysfunction, were recruited and tested. Currently accepted gold standard measures of static visual acuity, vestibular function, dynamic visual acuity, and balance were performed to determine validity. Repeat testing was performed to examine reliability. RESULTS: The DVA and BAM tests are affordable and appropriate for use for individuals 3 through 85 years of age. The DVA had fair to good reliability (0.41-0.94) and sensitivity and specificity (50%-73%), depending on age and optotype chosen. The BAM test was moderately correlated with center of pressure (r = 0.42-0.48) and dynamic posturography (r = -0.48), depending on age and test condition. Both tests differentiated those with and without vestibular impairment and the young from the old. Each test was reliable. CONCLUSION: The newly created DVA test provides a valid measure of visual acuity with the head still and moving quickly. The novel BAM is a valid measure of balance. Both tests are sensitive to age-related changes and are able to screen for impairment of the vestibular system.


Assuntos
National Institutes of Health (U.S.) , Testes de Função Vestibular/métodos , Acuidade Visual/fisiologia , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Coleta de Dados , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Software , Estados Unidos , Doenças Vestibulares/diagnóstico , Testes de Função Vestibular/normas , Adulto Jovem