RESUMO
Due to a lack of appropriate image resolution, most ultrasound scanners are unable to sensitively discern the pulley tissues. To extensively investigate the properties of the A1 pulley system and the surrounding tissues for assessing trigger finger, a 30 MHz ultrasound system was implemented to perform in vitro experiments using the hypodermis, A1 pulley, and superficial digital flexor tendon (SDFT) dissected from cadavers. Ultrasound signals were acquired from both the transverse and sagittal planes of each tissue sample. The quantitative ultrasonic parameters, including sound speed, attenuation coefficient, integrated backscatter (IB) and Nakagami parameter (m), were subsequently estimated to characterize the tissue properties. The results demonstrated that the acquired ultrasound images have high resolution and are able to sufficiently differentiate the variations of tissue textures. Moreover, the attenuation slope of the hypodermis is larger than those of the A1 pulley and SDFT. The IB of A1 pulley is about the same as that of the hypodermis, and is very different from SDFT. The m parameter of the A1 pulley is also very different from those of hypodermis and SDFT. This study demonstrated that high-frequency ultrasound images in conjunction with ultrasonic parameters are capable of characterizing the A1 pulley system and surrounding tissues.
Assuntos
Ultrassonografia , Cadáver , Humanos , Som , Tendões , Dedo em GatilhoRESUMO
Carpal tunnel syndrome (CTS) is typically diagnosed by physical examination or nerve conduction measurements. With these diagnostics however it is difficult to obtain anatomical information in the carpal tunnel. To further improve the diagnosis of CTS, an attempt using 30 MHz high-frequency ultrasound to noninvasively detect the local anatomical structures and the kinetic trajectory of the median nerve (MN) in the wrist was explored. Measurements were performed on the right wrist of 14 asymptomatic volunteers. The kinetic trajectory of the MN corresponding to flexion (from 0° to 90°) and extension (from 90° to 0°) movements of the fingers were detected by a cross correlation-based motion tracking technique. The average displacements of the MN according to finger movements were measured to be 3.74 and 2.04 mm for male and female subjects, respectively. Moreover, the kinetic trajectory of the MN in both the ulnar-palmar and total directions generally follows a sigmoidal curve tendency. This study has verified that the use of high-frequency ultrasound imaging and a motion tracking technique to sensitively detect the displacement and kinetic trajectory of the MN for the assessment of CTS patients is feasible.
Assuntos
Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/fisiologia , Amplitude de Movimento Articular/fisiologia , Ultrassonografia/métodos , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Marcadores Fiduciais , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/instrumentaçãoRESUMO
Conductive polymer composites, typically fabricated from a mix of conductive fillers and a polymer substrate, are commonly applied as bipolar plates in a fuel cell stack. Electrical conductivity is a crucial property that greatly depends on the distribution and orientation of the fillers. In this study, a 50-MHz ultrasound imaging system and analysis techniques capable of nondestructively assessing the properties of carbon fibers (CFs) in conductive polymer composites were developed. Composite materials containing a mix of polycarbonate substrates and 0 to 0.3 wt% of CFs were prepared using an injection molding technique. Ultrasonic A-line signals and C-scan images were acquired from each composite sample in regions at a depth of 0.15 mm beneath the sample surface (region A) and those at a depth of 0.3 mm (region B). The integrated backscatter (IB) and the Nakagami statistical parameter were calculated to quantitatively assess the samples. The area ratio, defined as the percentage of areas composed of CF images normalized by that of the whole C-scan image, was applied to further quantify the orientation of CFs perpendicular to the sample surface. Corresponding to the increase in CF concentrations from 0.1 to 0.3 wt%, the average IB and Nakagami parameter (m) of the composite samples increased from -78.10 ± 2.20 (mean ± standard deviation) to -72.66 ± 1.40 dB and from 0.024 ± 0.012 to 0.048 ± 0.011, respectively. The corresponding area ratios were respectively estimated to be 0.78 ± 0.35%, 2.33 ± 0.66%, and 2.20 ± 0.60% in region A of the samples; those of CFs with a perpendicular orientation were 0.04 ± 0.03%, 0.08 ± 0.02%, and 0.12 ± 0.05%. The area ratios in region B of the samples were calculated to be 1.19 ± 0.54%, 2.81 ± 0.42%, and 2.64 ± 0.76%, and those of CFs with a perpendicular orientation were 0.07 ± 0.04%, 0.12 ± 0.04%, and 0.14 ± 0.03%. According to the results of the orientations and ultrasonic images, CFs tended to distribute more uniformly in the deeper regions of the samples. This study validates that the distribution and orientation of CFs in conductive polymer composites could be sensitively and quantitatively assessed by high-frequency ultrasound in conjunction with current analysis methods.