1.
PLoS One ; 16(2): e0246031, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33524066

RESUMO

OBJECTIVES: The gold standard to obtain pressure-volume relations (PVR) of the heart, the conductance technology (PVRCond), is rarely used in children. PVR can also be obtained by 3D-echocardiography volume data combined with simultaneously measured pressure data by a mini pressure-wire (PVR3DE). We sought to investigate the feasibility of both methods in patients with univentricular hearts and to compare them, including hemodynamic changes. METHODS: We studied 19 patients (age 2-29 years). PVR3DE and PVRCond were assessed under baseline conditions and stimulation with dobutamine. RESULTS: Obtaining PVR3DE was successful in all patients. Obtaining PVRCond was possible in 15 patients during baseline (79%) and in 12 patients under dobutamine (63%). Both methods showed that end-systolic elastance (Ees) and arterial elastance (Ea) increased under dobutamine and that Tau showed a statistically significant decrease. Intraclass correlation (95% confidence interval) showed moderate to good agreement between methods: Ees: 0.873 (0.711-0.945), Ea: 0.709 (0.336-0.873), Tau: 0.867 (0.697-0.942). Bland-Altman analyses showed an acceptable bias with wider limits of agreement: Ees: 1.63 mmHg/ml (-3.83-7.08 mmHg/ml), Ea: 0.53 mmHg/ml (-5.23-6.28 mmHg/ml), Tau: -0,76 ms (-10.73-9.21 ms). CONCLUSION: Changes of PVR-specific parameters under dobutamine stimulation were reflected in the same way by both methods. However, the absolute values for these parameters could vary between methods and, therefore, methods are not interchangeable. Obtaining PVR3DE in a single ventricle was easier, faster and more successful than PVRCond. PVR3DE provides a promising and needed alternative to the conductance technology for the assessment of cardiac function in univentricular hearts.


Assuntos
Pressão Sanguínea , Ecocardiografia Tridimensional , Coração Univentricular/diagnóstico por imagem , Coração Univentricular/fisiopatologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Adulto Jovem
2.
J Clin Monit Comput ; 35(4): 859-868, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32535849

RESUMO

Integrating spontaneous breathing into mechanical ventilation (MV) can speed up liberation from it and reduce its invasiveness. On the other hand, inadequate and asynchronous spontaneous breathing has the potential to aggravate lung injury. During use of airway-pressure-release-ventilation (APRV), the assisted breaths are difficult to measure. We developed an algorithm to differentiate the breaths in a setting of lung injury in spontaneously breathing ewes. We hypothesized that differentiation of breaths into spontaneous, mechanical and assisted is feasible using a specially developed for this purpose algorithm. Ventilation parameters were recorded by software that integrated ventilator output variables. The flow signal, measured by the EVITA® XL (Lübeck, Germany), was measured every 2 ms by a custom Java-based computerized algorithm (Breath-Sep). By integrating the flow signal, tidal volume (VT) of each breath was calculated. By using the flow curve the algorithm separated the different breaths and numbered them for each time point. Breaths were separated into mechanical, assisted and spontaneous. Bland Altman analysis was used to compare parameters. Comparing the values calculated by Breath-Sep with the data from the EVITA® using Bland-Altman analyses showed a mean bias of - 2.85% and 95% limits of agreement from - 25.76 to 20.06% for MVtotal. For respiratory rate (RR) RRset a bias of 0.84% with a SD of 1.21% and 95% limits of agreement from - 1.53 to 3.21% were found. In the cluster analysis of the 25th highest breaths of each group RRtotal was higher using the EVITA®. In the mechanical subgroup the values for RRspont and MVspont the EVITA® showed higher values compared to Breath-Sep. We developed a computerized method for respiratory flow-curve based differentiation of breathing cycle components during mechanical ventilation with superimposed spontaneous breathing. Further studies in humans and optimizing of this technique is necessary to allow for real-time use at the bedside.


Assuntos
Respiração Artificial , Respiração , Animais , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Pulmão , Ovinos , Volume de Ventilação Pulmonar