Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Am J Cardiol ; 116(9): 1469-78, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26347004

RESUMO

We sought to compare the diagnostic performance of coronary computed tomography angiography (CCTA), computed tomography perfusion (CTP), and computed tomography (CT)-fractional flow reserve (FFR) for assessing the functional significance of coronary stenosis as defined by invasive FFR in patients with known or suspected coronary artery disease (CAD). CCTA has proved clinically useful for excluding obstructive CAD because of its high sensitivity and negative predictive value (NPV); however, the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP, or CT-FFR for the noninvasive detection of obstructive CAD compared with catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios, and odds ratio of all diagnostic tests were assessed. Eighteen studies involving a total of 1,535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56, and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77, respectively (p = 0.004 and p = 0.0009) resulting in higher point estimates for PPV 0.70 and 0.83, respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA vs 9.6 mSv CTP) and a higher volume of iodinated contrast (145 ml). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to noninvasively detect the functional significance of coronary lesions.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico , Angiografia Cintilográfica/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Medicina Baseada em Evidências , Humanos , Valor Preditivo dos Testes , Prognóstico , Sensibilidade e Especificidade , Índice de Gravidade de Doença
3.
Catheter Cardiovasc Interv ; 86(1): 40-1, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26097054

RESUMO

Intraprocedural thrombotic events (IPTE) during PCI occur in 4% of patients with NSTEACS and 12% of STEACS. IPTE increases hospital cost by $3,592. With an incidence of 4%, additional therapy to completely prevent IPTE in 100 patients would need to cost $144 to make it cost neutral. Further studies are necessary to determine cost-benefit of therapies to prevent IPTE such as cangrelor or newer P2Y12 inhibitors with more rapid onset.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Custos Hospitalares , Complicações Intraoperatórias/economia , Intervenção Coronária Percutânea/efeitos adversos , Trombose/economia , Feminino , Humanos , Masculino
4.
Cardiovasc Revasc Med ; 15(3): 156-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24767314

RESUMO

Aortic valve annular complex was rediscovered after the introduction of transcatheter aortic valve replacement; and imaging has been crucial in determining the annular geometry. Although the procedure has evolved, complications related to the annular mechanical response following valve implantation, such as aortic insufficiency, still occur in practice. We documented the feasibility of invasive assessment of aortic valve annular complex and the detection of induced aortic insufficiency via intravascular ultrasound with ChromaFlo® technology in a porcine model.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ultrassonografia de Intervenção/métodos , Animais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Modelos Animais de Doenças , Estudos de Viabilidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Valor Preditivo dos Testes , Suínos
5.
Clin Cardiol ; 32(12): E22-31, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20014211

RESUMO

BACKGROUND: While the role of hemoglobin in heart failure and renal disease has been investigated, little is known about its effect on clinical exercise test performance and mortality in patients referred for routine exercise treadmill testing (ETT). HYPOTHESIS: Patients with low hemoglobin will have poor exercise capacity and would be at increased risk of mortality and cardiovascular (CV) events. METHODS: Clinical variables, laboratory values, and exercise treadmill data were obtained for 1,799 patients referred for routine ETT from 1997 to 2004. All-cause mortality was obtained from the United States Social Security death index and autopsy reports or clinical notes were used to determine CV events and mortality. P values < 0.05 were considered significant. RESULTS: Our population had a mean age of 58 +/- 12 years, 16% had diabetes, 53% had hypertension, 35% had hypercholesterolemia, and 67% had a history of smoking. During follow-up, 10.3% of patients died, 3.9% of patients died of CV causes, and 11.6% had cardiovascular events. Anemic patients (hemoglobin [Hgb] < 13 g/dL) achieved lower metabolic equivalents (METs) than nonanemic patients and had more ST-segment depression (15.5% versus 8.6%, p < 0.004). Proportional hazard analysis demonstrated that hemoglobin was significantly associated with all-cause mortality (p < 0.0007), CV mortality (p < 0.009), and CV events (p < 0.01). Kaplan-Meier survival analysis demonstrated that anemic patients had significantly higher mortality and CV events. CONCLUSION: Hemoglobin is significantly associated with exercise performance, ST-segment depression during ETT, mortality, and cardiovascular events. The incorporation of hemoglobin may add diagnostic and prognostic information to ETT.


Assuntos
Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , Eletrocardiografia , Teste de Esforço , Tolerância ao Exercício , Hemoglobinas/análise , Fatores Etários , Anemia/epidemiologia , Índice de Massa Corporal , Cardiotônicos/uso terapêutico , Diabetes Mellitus/epidemiologia , Seguimentos , Humanos , Hipertensão/epidemiologia , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estados Unidos/epidemiologia
6.
Am J Cardiol ; 102(6): 679-82, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18773987

RESUMO

Recent studies have reported a higher incidence of late stent thrombosis in patients undergoing drug-eluting stent (DES). Reduced left ventricular (LV) ejection fraction (EF) is considered a risk factor for this complication after both bare-metal stent (BMS) and DES implantation. Therefore, the aim of this study was to evaluate the safety of DES on long-term follow-up in patients with LV dysfunction undergoing percutaneous coronary intervention. We retrospectively selected all patients with an EF <45% undergoing percutaneous coronary intervention with implantation of > or =1 sirolimus- or paclitaxel-eluting stent at our institution. The primary endpoint of the study was all-cause mortality, retrieved using both Social Security Database and hospital records. We also compared the results of this group with a historical cohort of patients with LV dysfunction undergoing BMS implantation; 121 patients who received > or =1 DES were enrolled. The mean LVEF was 36 +/- 8%, with 20 patients (16%) with a LVEF < or =25%; 36 patients (30%) had diabetes mellitus, and DES implantation was considered off-label in 100 patients (83%). Survival at 1-, 2-, and 3-year follow-up was 94% (95% confidence interval [CI] 88 to 100), 90% (95% CI 82 to 98) and 88% (95% CI 80 to 96), respectively. In conclusion, the favorable results of this study demonstrate the safety of DES in patients with LV dysfunction.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/cirurgia , Antagonistas Adrenérgicos beta/uso terapêutico , Diabetes Mellitus/epidemiologia , Feminino , Seguimentos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Estudos Retrospectivos , Sirolimo/administração & dosagem , Volume Sistólico , Análise de Sobrevida
7.
Clin Cardiol ; 29(1): 36-41, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16477776

RESUMO

BACKGROUND: While morbidity and mortality were shown to be increased in the setting of an elevated white blood cell (WBC) count for patients with acute coronary syndrome, the impact of statin therapy on mortality for patients with an elevated WBC count is unknown in high-risk patients with coronary artery disease. HYPOTHESIS: The goal of this study was to determine whether statin therapy improved survival in patients with elevated WBC count undergoing percutaneous coronary intervention (PCI) with preexisting left ventricular (LV) dysfunction, a population at high risk for adverse outcomes. METHODS: We retrospectively evaluated consecutive patient procedures performed at our institution from 1996 through 1999. Patients had a technically adequate angiographic left ventriculogram with a calculated ejection fraction (EF) < or = 50%. Patients with prior coronary artery bypass graft were excluded. Mortality data were retrieved using the U.S. Social Security Death Index. Follow-up ranged from 3.5 to 6.5 years. Means are provided with +/- standard deviation, and p values < 0.05 were considered significant. RESULTS: Of the study population of 238 patients (average EF 39 +/- 9.8%, mean age 57.5 +/- 12 years, 68% men) 61% underwent PCI for a recent myocardial infarction, 68% received stents, and 65% were discharged on statins. Mean WBC count was 9,000 +/- 3,100 cells/mm3, with 28% of patients having a WBC > or = 10,000 cells/mm3. During follow-up, 27% of our population died. Patients with a WBC > or = 10,000 had worse survival than patients with WBC < 10,000 (1-year survival: 86 vs. 96%, p < 0.05; 3-year survival: 79 vs. 89%, p < 0.05). Survival was significantly improved in patients on statin therapy regardless of WBC count, but the greatest benefit tended to be in patients with WBC > or = 10,000 (WBC > or = 10,000; odds ratio [OR] 5.14, 95% confidence interval [CI] 1.44-19.0, WBC < 10,000; OR 2.79,95% CI 1.13-7.1). Proportional hazard regression analysis demonstrated that both statin therapy and WBC count predicted mortality. CONCLUSION: Patients undergoing PCI with LV dysfunction discharged on statins had improved survival regardless of WBC count, with a trend for greater improvement in patients with elevated WBC counts. In addition, WBC count predicts mortality in this high-risk population with LV dysfunction undergoing PCI.


Assuntos
Angioplastia Coronária com Balão , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Contagem de Leucócitos , Isquemia Miocárdica/sangue , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/terapia , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/mortalidade , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/mortalidade
8.
Catheter Cardiovasc Interv ; 66(4): 547-53, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16216018

RESUMO

While earlier studies of balloon angioplasty (BA) in patients with left ventricular (LV) dysfunction suggested high late mortality, a study directly comparing coronary stenting and BA has not been performed. Since stenting provides a more durable revascularization, we sought to compare long-term survival in patients undergoing stenting vs BA in patients with decreased left ventricular ejection fractions (LVEF). We evaluated consecutive patient procedures performed in our institution from 1996 through 1999. Patients were considered part of the stent group if they received at least one stent. To be included, patients had to have a technically adequate angiographic LV gram with a calculated LVEF

Assuntos
Angioplastia Coronária com Balão , Implante de Prótese Vascular/instrumentação , Doença das Coronárias/mortalidade , Stents , Disfunção Ventricular Esquerda/mortalidade , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA