Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Immunol Res ; 67(1): 93-97, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30498955

RESUMO

Cystic echinococcosis (CE) is a neglected helminthic zoonosis caused by the larval stage of the tapeworm Echinococcus granulosus s.l. MicroRNAs (miRNAs) are regulators of gene expression that have been linked with the pathogenesis of several human diseases, but little exists in the available literature about miRNAs in CE. Here, we investigate the expression profiles of 84 microRNAs relevant to the function of lymphocytes and other immune cells during CE infection in the peripheral blood of patients with cysts in active and inactive stages. We applied the microRNA PCR array technology to blood samples from 20 patients with a single hepatic CE cyst in either the active (CE3b) or inactive (CE4-CE5) stage. Our results show a significant upregulation of eight miRNAs (let-7g-5p, let-7a-5p, miR- 26a-5p, miR- 26b-5p, miR- 195-5p, miR- 16-5p, miR- 30c-5p, and miR- 223-3p) in patients with active cysts compared to those with inactive cysts. The high expression of these miRNAs in patients with active cysts suggests their role in a specific host immune response against the infection. Further work in this direction may help shed light on the pathogenesis of human CE.


Assuntos
Equinococose/imunologia , Echinococcus granulosus/fisiologia , Fígado/patologia , MicroRNAs/genética , Animais , Equinococose/genética , Ensaio de Imunoadsorção Enzimática , Humanos , Imunidade Inata/genética , Estágios do Ciclo de Vida , Fígado/parasitologia , Regulação para Cima
2.
Immunol Res ; 67(1): 98, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30591988

RESUMO

The published article unfortunately contained mistake. After replacing the image from colored version to black and white, the Fig. 1 caption, unfortunately, was left unupdated.

3.
Am J Trop Med Hyg ; 99(4): 1006-1010, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30039784

RESUMO

Albendazole (ABZ) is the best drug available to treat cystic echinococcosis (CE), a neglected tropical disease. Cystic echinococcosis patients often receive a continuous course of the drug for 6-12 months. In Italy, ABZ shortages occur almost on a yearly basis. We searched clinical records at the World Health Organization Collaborating Center for the Clinical Management of CE in Pavia, Italy, to estimate the amount of ABZ prescribed to patients between January 2012 and February 2017. The cost of ABZ was estimated at €2.25 per tablet based on the current market price in Italy. Patients to whom ABZ had been prescribed were contacted to determine if they had experienced difficulties in purchasing the drug and to assess how such problems affected their treatment. Of 348 identified CE patients, 127 (36.5%) were treated with ABZ for a total of 20,576 days. This led to an estimated cost of €92,592. Seventy-five patients were available for follow-up, 42 (56%) reported difficulties in obtaining ABZ. Of these patients, four (9.5%) had to search out of their region and 10 (23.8%) had to go out of the country. A total of 27 patients (64%) had to visit more than five pharmacies to locate the drug and 10 patients (23.8%) interrupted treatment because of ABZ nonavailability. Shortages in ABZ distribution can disrupt CE treatment schedules and jeopardize patient health.


Assuntos
Albendazol/provisão & distribuição , Anti-Helmínticos/provisão & distribuição , Custos de Medicamentos/estatística & dados numéricos , Equinococose/tratamento farmacológico , Custos de Cuidados de Saúde/estatística & dados numéricos , Gastos em Saúde/estatística & dados numéricos , Albendazol/economia , Animais , Anti-Helmínticos/economia , Uso de Medicamentos/estatística & dados numéricos , Equinococose/parasitologia , Echinococcus granulosus/efeitos dos fármacos , Echinococcus granulosus/fisiologia , Humanos , Itália , Centros de Cuidados de Saúde Secundários , Comprimidos
4.
BMC Gastroenterol ; 17(1): 61, 2017 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-28472948

RESUMO

BACKGROUND: To assess the clinical validity of controlled attenuation parameter (CAP) in the diagnosis of hepatic steatosis in a series of overweight or obese children by using the imperfect gold standard methodology. METHODS: Consecutive children referred to our institution for auxological evaluation or obesity or minor elective surgery were prospectively enrolled. Anthropometric and biochemical parameters were recorded. Ultrasound (US) assessment of steatosis was carried out using ultrasound systems. CAP was obtained with the FibroScan 502 Touch device (Echosens, Paris, France). Pearson's or Spearman's rank correlation coefficient were used to test the association between two study variables. Optimal cutoff of CAP for detecting steatosis was 249 dB/m. The diagnostic performance of dichotomized CAP, US, body mass indexes (BMI), fatty liver index (FLI) and hepatic steatosis index (HSI) was analyzed using the imperfect gold standard methodology. RESULTS: Three hundred five pediatric patients were enrolled. The data of both US and CAP were available for 289 children. Steatosis was detected in 50/289 (17.3%) children by US and in 77/289 (26.6%) by CAP. A moderate to good correlation was detected between CAP and BMI (r = 0.53), FLI (r = 0.55) and HSI (r = 0.56). In obese children a moderate to good correlation between CAP and insulin levels (r = 0.54) and HOMA-IR (r = 0.54) was also found. Dichotomized CAP showed a performance of 0.70 (sensitivity, 0.72 [0.64-0.79]; specificity, 0.98 [0.97-0.98], which was better than that of US (performance, 0.37; sensitivity, 0.46 [0.42-0.50]; specificity, 0.91 [0.89-0.92]), BMI (performance, 0.22; sensitivity, 0.75 [0.73-0.77]; specificity, 0.57 [0.55-0.60]) and FLI or HSI. CONCLUSIONS: For the evaluation of liver steatosis in children CAP performs better than US, which is the most widely used imaging technique for screening patients with a suspicion of liver steatosis. A cutoff value of CAP of 249 dB/m rules in liver steatosis with a very high specificity.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso/complicações , Fígado Gorduroso/diagnóstico por imagem , Sobrepeso/complicações , Obesidade Infantil/complicações , Adolescente , Teorema de Bayes , Criança , Pré-Escolar , Estudos Transversais , Fígado Gorduroso/sangue , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Estudos Prospectivos , Valores de Referência , Ultrassonografia
5.
J Gastrointestin Liver Dis ; 25(3): 331-5, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27689197

RESUMO

BACKGROUND AND AIMS: Noninvasive assessment of liver stiffness has been increasingly used to evaluate fibrosis instead of liver biopsy, especially in patients with chronic viral hepatitis. The aim of this study was to assess the performance in staging liver fibrosis of the updated ElastPQ® technique (EPIQ7 ultrasound system, Philips Healthcare, Bothell, WA, USA) in the "real life" setting by using the FibroScan as the reference standard and to understand whether the use of the quality criteria improves the performance of the technique. METHODS: This was a cross-sectional study: 278 patients affected by chronic hepatitis C referred for liver stiffness measurement with the FibroScan® 502 Touch device (Echosens, Paris, France) underwent measurements also with the ElastPQ® technique. For the assessment of significant fibrosis (F>/=2), advanced fibrosis (F>/=3) and cirrhosis (F=4), respectively, we used the cutoffs of 7.0, 9.5 and 12.0 kPa. The diagnostic performance of ElastPQ® was assessed using the area under the ROC (AUROC) curve analysis and was evaluated overall and for cases with (a) 10 measurements and IQR/M30%, (d) 5 measurements and IQR/M>30%. RESULTS: The optimal cutoffs of ElastPQ® for significant fibrosis, advanced fibrosis and cirrhosis were 6.43, 9.54 and 11.34 kPa, respectively. For measurements with an IQR/M/=2, F>/=3, and F=4, respectively). CONCLUSION: The ElastPQ® technique is reliable and accurate for staging liver fibrosis. The number of measurements does not affect the performance.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite C Crônica/virologia , Cirrose Hepática/diagnóstico por imagem , Idoso , Área Sob a Curva , Estudos Transversais , Técnicas de Imagem por Elasticidade/normas , Feminino , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico , Humanos , Itália , Cirrose Hepática/virologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Padrões de Referência , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
6.
Liver Int ; 36(12): 1860-1866, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27439331

RESUMO

BACKGROUND & AIMS: Ultrasound is the imaging modality most widely utilized in the general population for diagnostic purposes. Controlled attenuation parameter is a novel noninvasive method for assessing steatosis. Our aim was to investigate whether the clinical value of controlled attenuation parameter in patients referred for abdominal ultrasound examinations is affected by liver fibrosis. METHODS: Consecutive patients referred for abdominal ultrasound examinations were enrolled. Controlled attenuation parameter and liver stiffness were assessed with the FibroScan (Echosens, France). Liver fibrosis was staged according to published cutoffs of liver stiffness measurements. Pearson's or Spearman's rank correlation coefficient was used to test the association between two study variables. Optimal cutoff of controlled attenuation parameter for diagnosing liver steatosis (S≥2) was 256 dB/m. The diagnostic performance and accuracy of dichotomized controlled attenuation parameter, ultrasound and body mass index were analysed using the imperfect gold standard methodology. RESULTS: A total of 726 subjects (464 males and 262 females) were studied. Five hundred and eight-nine (81.1%) patients were affected by chronic viral hepatitis. Correlation of controlled attenuation parameter with ultrasound score was 0.48 and 0.57 in patients with and without chronic viral hepatitis respectively. In patients with chronic viral hepatitis, ultrasound, dichotomized controlled attenuation parameter and body mass index showed performance of 58.2%, 82.3% and 46.7%, respectively, whereas in patients without chronic viral hepatitis, the performance was 86.4%, 68.6% and 48.6% respectively. CONCLUSIONS: In patients with chronic viral hepatitis and advanced liver fibrosis, controlled attenuation parameter performs better than ultrasound for assessing liver steatosis, whereas in patients without viral hepatitis and with nonsignificant liver disease ultrasound shows the best performance.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Área Sob a Curva , Índice de Massa Corporal , Estudos Transversais , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
7.
Eur Radiol ; 24(6): 1283-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24643497

RESUMO

OBJECTIVES: To evaluate reproducibility of measurements of spleen stiffness (SS) and liver stiffness (LS) at several sites by using point shear wave elastography (pSWE) and to investigate any training effect. METHODS: Healthy volunteers were consecutively enrolled. Measurements of SS and LS were performed by an expert (observer 1) and a novice (observer 2) at three different sites of liver and spleen. To assess the effect of training the study was conducted in two periods (period 1 and period 2). Concordance correlation coefficient was used to assess intra-observer and inter-observer reproducibility. RESULTS: A total of 92 subjects (67 men and 25 women) were enrolled in the study. Both intra-observer and inter-observer agreement were higher for the liver than for the spleen. Overall, the highest intra-observer and inter-observer agreement were obtained for the assessment of LS through intercostal space, and for measurements at this site there was a significantly better performance of observer 2 after the training period. For both observers, training improved the repeatability of SS measurements at all sites. A good intra-observer agreement was obtained only for measurements at the spleen lower pole. CONCLUSIONS: The results of this study show that a learning curve in pSWE acquisition should be taken into account both for SS and LS measurements. KEY POINTS: Reproducibility of SS measurements depends on the expertise of the operator. To achieve good reproducibility between measurements a training period is required. A learning curve in pSWE acquisition should be taken into account. SS measurements are less reproducible than LS measurements.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Fígado/diagnóstico por imagem , Baço/diagnóstico por imagem , Adulto , Estudos Transversais , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
10.
AJR Am J Roentgenol ; 199(1): 19-25, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22733889

RESUMO

OBJECTIVE: The purpose of this article is to evaluate the diagnostic performance of transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index in assessing fibrosis in patients with chronic hepatitis C by using histologic Metavir scores as reference standard. SUBJECTS AND METHODS: Consecutive patients with chronic hepatitis C scheduled for liver biopsy were enrolled. Liver biopsy was performed on the same day as transient elastography and real-time strain elastography. Transient elastography and real-time strain elastography were performed in the same patient encounter by a single investigator using a medical device based on elastometry and an ultrasound machine, respectively. Diagnostic performance was assessed by using receiver operating characteristic curves and area under the receiver operating characteristic curve (AUC) analysis. RESULTS: One hundred thirty patients (91 men and 39 women) were analyzed. The cutoff values for transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index were 6.9 kPa, 1.82, and 0.37, respectively, for fibrosis score of 2 or higher; 7.3 kPa, 1.86, and 0.70, respectively, for fibrosis score of 3 or higher; and 9.3 kPa, 2.33, and 0.70, respectively, for fibrosis score of 4. AUC values of transient elastography, real-time strain elastography, aspartate-to-platelet ratio index were 0.88, 0.74, and 0.86, respectively, for fibrosis score of 2 or higher; 0.95, 0.80, and 0.89, respectively, for fibrosis score of 3 or higher; and 0.97, 0.80, and 0.84, respectively, for fibrosis score of 4. A combination of the three methods, when two of three were in agreement, showed AUC curves of 0.93, 0.95, and 0.95 for fibrosis scores of 2 or higher, 3 or higher, and 4, respectively. CONCLUSION: Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and cirrhosis. Real-time elastography does not yet have the potential to substitute for transient elastography in the assessment of liver fibrosis.


Assuntos
Ácido Aspártico/sangue , Técnicas de Imagem por Elasticidade , Hepatite C Crônica/complicações , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Adulto , Área Sob a Curva , Biópsia , Plaquetas/metabolismo , Progressão da Doença , Feminino , Seguimentos , Humanos , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA