Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Biochem ; 120: 110655, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37769933

RESUMO

OBJECTIVE: Pleural effusion (PE) is a common clinical complication associated with various disorders. We aimed to utilize laboratory variables and their corresponding ratios in serum and PE for the differential diagnosis of multiple types of PE based on a decision tree (DT) algorithm. METHODS: A total of 1435 untreated patients with PE admitted to The First Affiliated Hospital of Ningbo University were enrolled. The demographic and laboratory variables were collected and compared. The receiver operating characteristic curve was used to select important variables for diagnosing malignant pleural effusion (MPE) or tuberculous pleural effusion (TPE) and included in the DT model. The data were divided into the training set and the test set at a ratio of 7:3. The training data was used to develop the DT model, and the test data was for evaluating the model. Independent data was collected as external validation. RESULTS: Three PE indicators (carcinoembryonic antigen, adenosine deaminase [ADA], and total protein), two serum indicators (neuron-specific enolase and cytokeratin 19 fragments), and two ratios [high-sensitivity C-reactive protein (hsCRP)/ PE lymphocyte and hsCRP/PE ADA] were used to construct the DT model. The area under the curve (AUC), sensitivity, and specificity for diagnosing MPE were 0.963, 84.0%, 91.6% in the training set, 0.976, 84.1%, 88.6% in the test set, and 0.955,83.3%, 86.7% in the external validation set. The AUC, sensitivity, and specificity of diagnosing TPE were 0.898, 86.8%, 92.3% in the training set, 0.888, 88.8%, 92.7% in the test set, and 0.778, 84.8%, 94.3% in the external validation set. CONCLUSION: The DT model showed good diagnostic efficacy and could be applied for the differential diagnosis of MPE and TPE in clinical settings.

2.
J Environ Manage ; 305: 114348, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34953222

RESUMO

Benzene, toluene, ethylbenzene, and xylenes (BTEX) released from landfills have received increased attention because of their health risks. In this study, individual external and internal exposures of BTEX in a municipal solid waste (MSW) landfill were simultaneously studied for the first time. Eight workers from the landfill (as the case group) and eight control subjects were enrolled in the study. In total, 88 air samples and 232 urine samples (194 samples from the case group and 38 samples from the control group) were obtained from 2018 to 2019. According to the results of external exposure monitoring, benzene was the predominant component of BTEX, and the exposure level was higher in winter than in other seasons. Carcinogenic (RiskT) and noncarcinogenic (HIT) risks were calculated based on a dose-response model. The RiskT (1.64 × 10-8-1.09 × 10-6) might exceeded the limit, whereas HIT (9.84 × 10-4-1.40 × 10-2) was within their thresholds. Benzene was the major contributor to both RiskT and HIT. Internal exposures were evaluated by measuring urinary metabolites of BTEX. Levels of urinary BTEX metabolites for case group were higher than those for control group. A remarkable increase in urinary metabolites was observed from the urine samples of the case group after their shift compared with those before their shift. t,t-MA, the metabolite of benzene, was found to exceed the biomonitoring guidance limits of both China and the United States of America. Landfills can be considered as a potential BTEX exposure source for landfill employees. Minimizing occupational exposures and appropriate personal protective equipment are needed in reducing BTEX exposures.


Assuntos
Poluentes Atmosféricos , Xilenos , Poluentes Atmosféricos/análise , Benzeno , Derivados de Benzeno , Monitoramento Ambiental , Humanos , Medição de Risco , Resíduos Sólidos , Tolueno , Instalações de Eliminação de Resíduos
3.
J Orthop Surg Res ; 16(1): 305, 2021 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-33964958

RESUMO

BACKGROUND: Soft tissue balancing is essential for the success of total knee arthroplasty (TKA) and is mainly dependent on surgeon-defined assessment (SDA) or a gap-balancer (GB). However, an electronic sensor has been developed to objectively measure the gap pressure. This study aimed to evaluate the accuracy of soft tissue balancing using SDA and GB compared with a sensor. METHODS: Forty-eight patients undergoing TKA (60 knees) were prospectively enrolled. Soft tissue balancing was sequentially performed using SDA, a GB, and an electronic sensor. We compared the SDA, GB, and sensor data to calculate the sensitivity, specificity, and accuracy at 0°, 45°, 90°, and 120° flexion. Cumulative summation (CUSUM) analysis was performed to assess the surgeon's performance during the sensor introductory phase. RESULTS: The sensitivity of SDA was 63.3%, 68.3%, 80.0%, and 80.0% at 0°, 45°, 90°, and 120°, respectively. The accuracy of the GB compared with sensor data was 76.7% and 71.7% at 0° and 90°, respectively. Cohen's kappa coefficient for the accuracy of the GB was 0.406 at 0° (moderate agreement) and 0.227 at 90° (fair agreement). The CUSUM 0° line achieved good prior performance at case 45, CUSUM 90° and 120° showed a trend toward good prior performance, while CUSUM 45° reached poor prior performance at case 8. CONCLUSION: SDA was a poor predictor of knee balance. GB improved the accuracy of soft tissue balancing, but was still less accurate than the sensor, particularly for unbalanced knees. SDA improved with ongoing use of the sensor, except at 45° flexion.


Assuntos
Artroplastia do Joelho/métodos , Tecido Conjuntivo/fisiologia , Eletrônica Médica/instrumentação , Prótese do Joelho , Osteoartrite do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Cirurgiões , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Curva de Aprendizado , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 42(2): 222-227, 2020 Apr 28.
Artigo em Chinês | MEDLINE | ID: mdl-32385029

RESUMO

Objective To tailor the subsequent treatment and follow-up strategy,this study dynamically assessed the response to initial therapy in non-distant metastatic differentiated thyroid cancer (DTC) patients with intermediate and high risk. Methods A total of 184 non-distant metastatic DTC patients (intermediate-risk 111 cases and high-risk 73 cases) were retrospectively enrolled in this study. Based on the results of initial response assessment (6-12 months after initial therapy),patients were divided into two groups:excellent response (ER) group (n=113) and non-excellent response (non-ER) group (n=71). We compared the differences in clinicopathological features between these 2 groups and evaluated the changes of dynamic response to therapy at the initial and final assessments after initial therapy in all patients. Results Compared with the ER group,the non-ER group showed a larger tumor size (U=2771.500,P=0.000),higher proportion of extrathyroidal invasion (χ 2=4.070,P=0.044),and higher preablative-stimulated thyroglobulin levels (U=1367.500,P=0.000). ER was achieved in 31% of patients in the initial non-ER group [including indeterminate response (IDR) and biochemical incomplete response (BIR)] at the final follow-up only by thyroid stimulating hormone (TSH) suppression therapy,among which 63.6% were with intermediate risk (especially the patients with IDR) and 36.4% at high risk. In addition,5.2%(6/113) of patients in the initial ER group were reassessed as IDR,BIR,or even structural incomplete response at the end of the follow-up (among which one patient developed into cervical lymph node recurrence,as confirmed by pathology);the TSH level in these patients fluctuated at 0.56-10.35 µIU/ml and was not corrected in time during the follow-up after initial therapy. Conclusions Some of non-distant metastatic DTC patients with intermediate and high risks who presented initial non-ER may achieve ER only by TSH suppression therapy over time;in contrast,the patients presented initial ER may develop into non-ER without normalized TSH suppression therapy. The dynamic risk assessment system may provide a real-time assessment of recurrence risk and tailor the subsequent treatment and follow-up strategies.


Assuntos
Medição de Risco , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/terapia , Seguimentos , Humanos , Metástase Neoplásica , Recidiva Local de Neoplasia , Estudos Retrospectivos , Tireoglobulina/sangue , Tireotropina/antagonistas & inibidores
5.
Pain Res Manag ; 2019: 8957847, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31511784

RESUMO

Chronic nonspecific low back pain (CNLBP) is defined as pain or discomfort originating from the waist, which lasts for at least 12 weeks, but no radiculopathy or specific spinal diseases. CNLBP is a complicated medical problem and places a huge burden on healthcare systems. Clinical manifestation of CNLBP includes discogenic LBP, zygapophyseal joint pain, sacroiliac joint pain, and lumbar muscle strain. Further evaluation should be completed to confirm the diagnosis including auxiliary examination, functional assessment, and clinical assessment. The principle of the management is to relieve pain, restore function, and avoid recurrence. Treatment includes conservative treatment, minimally invasive treatment, and rehabilitation. Pharmacologic therapy is the first-line treatment of nonspecific LBP, and it is most widely used in clinical practice. Interventional therapy should be considered only after failure of medication and physical therapy. Multidisciplinary rehabilitation can improve physical function and alleviate short-term and long-term pain. The emphasis should be put on the prevention of NLBP and reducing relevant risk factors.


Assuntos
Dor Lombar/diagnóstico , Dor Lombar/terapia , Povo Asiático , Dor Crônica/diagnóstico , Dor Crônica/terapia , Consenso , Humanos
6.
J Magn Reson Imaging ; 46(5): 1311-1319, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28252868

RESUMO

PURPOSE: To evaluate the accuracy of magnetic resonance elastography (MRE) in comparison to contrast-enhanced computed tomography (CE-CT) for early diagnosis and prediction of severity in acute pancreatitis (AP). MATERIALS AND METHODS: This cross-sectional prospective study included 76 patients with suspected AP who underwent both CE-CT and 3.0T MRE within 24 hours of hospital admission. Pancreatic stiffness, CT severity index (CTSI), Acute Physiology and Chronic Health Evaluation (APACHE)-II, and Bedside Index for Severity in AP (BISAP) scores were comparatively evaluated using data from the first 24 hours of admission, and diagnosis and severity of AP were confirmed according to the revised Atlanta Classification (2012). The accuracy of MRE for predicting disease severity was compared with that of CE-CT and the clinical scoring systems using area under the receiver-operating curve (AUC) analysis. RESULTS: AP was confirmed in 56/76 patients (73.7%). Pancreatic stiffness values of >1.47 kPa showed significantly better diagnostic performance than CE-CT (AUC: 0.993 vs. 0.818, P < 0.001) along with greater sensitivity (96.4% vs. 78.6%, P = 0.006) and accuracy (96.1% vs. 81.6%, P = 0.007). Ten patients (10/76; 13.2%) had clinically severe AP. The accuracy of pancreatic stiffness >2.47 kPa was comparable to that of the CTSI, APACHE-II and BISAP scores for predicting severe AP (accuracy = 85.5%, 75.0%, 88.2%, and 78.9%, respectively). The pairwise comparisons were not significant after Bonferroni correction (P < 0.008 [0.05/6]), with P values of 0.008 (MRE vs. CTSI), 0.823 (MRE vs. APACHE-II) and 0.414 (MRE vs. BISAP). CONCLUSION: Early MRE is a useful, noninvasive method for both diagnosis and early severity assessment of AP. We recommend MRE at hospital admission for initial evaluation of AP. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1311-1319.


Assuntos
Meios de Contraste/química , Imagem Ecoplanar , Pancreatite/diagnóstico por imagem , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , APACHE , Dor Abdominal , Doença Aguda , Índice de Massa Corporal , Estudos Transversais , Técnicas de Imagem por Elasticidade , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Pancreatite/fisiopatologia , Admissão do Paciente , Valor Preditivo dos Testes , Pressão , Estudos Prospectivos , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA