Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Gastrointest Endosc Clin N Am ; 33(3): 533-546, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245934

RESUMO

Pancreatic cystic lesions are frequently identified on cross-sectional imaging. As many of these are presumed branch-duct intraductal papillary mucinous neoplasms, these lesions generate much anxiety for the patients and clinicians, often necessitating long-term follow-up imaging and even unnecessary surgical resections. However, the incidence of pancreatic cancer is overall low for patients with incidental pancreatic cystic lesions. Radiomics and deep learning are advanced tools of imaging analysis that have attracted much attention in addressing this unmet need, however, current publications on this topic show limited success and large-scale research is needed.


Assuntos
Adenocarcinoma Mucinoso , Carcinoma Ductal Pancreático , Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/cirurgia , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Pâncreas/patologia , Cisto Pancreático/diagnóstico por imagem
2.
Eur J Radiol Open ; 4: 95-100, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28761907

RESUMO

PURPOSE: To assess intra-observer, inter-observer and inter-modality (CT vs. MRI) reproducibility of liver surface nodularity (LSN) scores measured with software used for detection of liver fibrosis. METHODS: This IRB-approved retrospective study included patients with both abdominal CT and MRI within 6 months of histopathologic sampling. Two independent observers used post-processing software to quantify LSN scores on axial non-contrast CT (NCT), axial contrast-enhanced CT (CECT), axial T2-weighted (T2W) HASTE, and axial and coronal post-gadoxetic acid T1-weighted (T1W) images obtained during the hepatobiliary phase (HBP). Ten slices were used to acquire the LSN scores. Intra-observer, inter-observer, and inter-modality (CT vs. MRI) reproducibility were assessed with intraclass correlation coefficient (ICC) and coefficients of variability (CV). Accuracy for detection of cirrhosis was evaluated for each technique. RESULTS: 26 patients (M/F 19/7, mean age 57 years), including 7 with cirrhosis (26.9%), were assessed. Technical failure occurred with NCT (1/23, 4.3%) and T2 HASTE (8/28, 28.6%). Intra-observer reproducibility was excellent for NCT, CECT, axial and coronal T1W HBP [ICC ≥ 0.92, CV ≤ 8%]. Inter-observer reproducibility was also excellent for NCT and CECT (ICC ≥ 0.95, CV ≤ 7.3%) and for coronal T1W HBP (ICC = 0.84, CV = 5.6%). There was fair to moderate agreement between CT and MRI (ICC 0.20-0.44). There were significant differences in mean LSN scores between non-cirrhotic and cirrhotic patients with NCT (2.6 vs. 4.2, p = 0.04) and T1W HBP (3.7 vs. 4.6; p = 0.01) images, with AUCs of 0.81 and 0.82, respectively. CONCLUSIONS: LSN measurement is highly reproducible with NCT and post-contrast T1W HBP on MRI, with different results obtained between CT and MRI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA