Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 42(9): 2272-2278, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28396918

RESUMO

PURPOSE: To compare hepatobiliary phase (HBP) images obtained 10 and 20 min after Gd-EOB-DTPA-enhanced MRI for liver function assessment in clinic on 3.0 T MR imaging. METHODS: 103 patients were separated into four groups: 38 patients for the normal liver function (NLF) group, 33 patients for the liver cirrhosis with Child-Pugh A (LCA) group, 21 patients for the liver cirrhosis with Child-Pugh B group, and 11 patients for a liver cirrhosis with Child-Pugh C group. T1 relaxation times (T1rt) were measured on T1 mapping and reduction rates of T1rt (rrT1rt) were calculated. HBP images were obtained at the 10- and 20-min mark after Gd-EOB-DTPA enhancement. RESULTS: T1rt on pre-enhancement imaging showed no significant difference (p > 0.05) among all four groups. T1rt for both the 10-min HBP and the 20-min HBP showed a significant difference (p < 0.05) among all groups, but showed no significant difference (p > 0.05) between the NLF group and the LCA group. T1rt and rrT1rt showed no significant difference (p > 0.05) between 10-min HBP and 20-min HBP among all groups. The ROC analysis on 10-min HBP and 20-min HBP showed a lower diagnostic performance between NLF group and LCA group (AUC from 0.532 to 0.582), but high diagnostic performance (AUC from 0.788 to 1.000) among others group. CONCLUSIONS: In comparing 10-min HBP and 20-min HBP T1 mapping after Gd-EOB-DTPA enhancement, our results suggest that 10-min HBP T1 mapping is a feasible option for quantitatively assessing liver function.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Hepatopatias/diagnóstico por imagem , Hepatopatias/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
2.
Radiol Med ; 122(4): 239-247, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28070844

RESUMO

OBJECTIVES: To compare hepatobiliary phase (HBP) images obtained at 10 and 20 min after Gd-EOB-DTPA-enhanced MRI for assessment of liver function in rabbit fibrosis model on 3.0 T MR imaging. METHODS: 34 animals were separated into three groups: 5 for a control group, 14 for a mild fibrosis group, and 15 for a severe fibrosis group based on pathological proof. T1 relaxation times (T1rt) were measured on T1 mapping and reduction rates of T1rt (rrT1rt) were calculated. HBP images were obtained at 10 and 20 min after Gd-EOB-DTPA enhancement. Indocyanine green retention rates at 15 min (ICG R15) were performed for all animals. RESULTS: T1rt on pre-enhancement imaging showed no significant difference (p > 0.05) among all groups. T1rt on 10 min HBP and 20 min HBP showed significant difference (p < 0.05) among all groups. T1rt and rrT1rt in three groups showed no-significant difference (p > 0.05) between 10 min HBP and 20 min HBP. T1rt on both 10 and 20 min HBP showed significant correlation with ICG R15 (p < 0.05); rrT1rt on both 10 min HBP and 20 min HBP showed significant inverse correlation with ICG R15 (p < 0.05). CONCLUSIONS: Comparing 10 min HBP and 20 min HBP T1 mapping after Gd-EOB-DTPA enhancement, our results suggest that 10 min HBP T1 mapping is feasible for quantitatively assessing liver function.


Assuntos
Gadolínio DTPA , Aumento da Imagem/métodos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Animais , Meios de Contraste , Modelos Animais de Doenças , Processamento de Imagem Assistida por Computador , Testes de Função Hepática , Estudos Prospectivos , Coelhos , Distribuição Aleatória , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA