Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
JTO Clin Res Rep ; 4(2): 100457, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36718140

RESUMO

Introduction: Gene fusion testing of ALK, ROS1, RET, NTRK, and MET exon 14 skipping mutations is guideline recommended in nonsquamous NSCLC (NS-NSCLC). Nevertheless, assessment is often hindered by the limited availability of tissue and prolonged next-generation sequencing (NGS) testing, which can protract the initiation of a targeted therapy. Therefore, the development of faster gene fusion assessment is critical for optimal clinical decision-making. Here, we compared two ultrafast gene fusion assays (UFGFAs) using NGS (Genexus, Oncomine Precision Assay, Thermo Fisher Scientific) and a multiplex reverse-transcriptase polymerase chain reaction (Idylla, GeneFusion Assay, Biocartis) approach at diagnosis in a retrospective series of 195 NS-NSCLC cases and five extrapulmonary tumors with a known NTRK fusion. Methods: A total of 195 NS-NSCLC cases (113 known gene fusions and 82 wild-type tumors) were included retrospectively. To validate the detection of a NTRK fusion, we added five NTRK-positive extrathoracic tumors. The diagnostic performance of the two UFGFAs and standard procedures was compared. Results: The accuracy was 92.3% and 93.1% for Idylla and Genexus, respectively. Both systems improved the sensitivity for detection by including a 5'-3' imbalance analysis. Although detection of ROS1, MET exon 14 skipping, and RET was excellent with both systems, ALK fusion detection was reduced with sensitivities of 87% and 88%, respectively. Idylla had a limited sensitivity of 67% for NTRK fusions, in which only an imbalance assessment was used. Conclusions: UFGFA using NGS and reverse-transcriptase polymerase chain reaction approaches had an equal level of detection of gene fusion but with some technique-specific limitations. Nevertheless, UFGFA detection in routine clinical care is feasible with both systems allowing faster initiation of therapy and a broad degree of screening.

2.
J Thorac Oncol ; 15(9): 1535-1540, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32450274

RESUMO

INTRODUCTION: Tumor mutational burden (TMB) has been proposed as a novel predictive biomarker for the stratification of patients with NSCLC undergoing immune checkpoint inhibitor (ICI) treatment. The assessment of TMB has recently been established using large targeted sequencing panels, and numerous studies are ongoing to harmonize TMB assessment. "Correlation" or the coefficient of determination has generally been used to evaluate the association between different panels. We hypothesized that these metrics might overestimate the comparability, especially for lower TMB values. METHODS: A total of 30 samples from patients with NSCLC undergoing ICI treatment were consecutively sequenced using the following three large, targeted sequencing panels: FoundationOne, Oncomine TML, and QiaSeq TMB. The TMB values were compared in the whole patient population and in a subset of patients in which the TMB assessed by FoundationOne was between 5 and 25 mutations/Mb. Prediction of durable clinical benefit (>6 mo with no progression) was assessed using receiver operator characteristics, and optimal cutoff values were calculated using the Youden J statistic. RESULTS: Correlation between the three targeted sequencing panels was strong in the whole patient population (R2 > 0.79) but was dramatically reduced in the subset of patients with TMB of 5 to 25 mutations/Mb. The agreement assessed using the Bland-Altman method was also very low. All panels were able to predict durable clinical benefit in the TMB-high population. CONCLUSIONS: Assessment of TMB using the three targeted sequencing panels was possible and predictive of response to ICI treatment, but correlation was an inappropriate measurement to assess the association between the respective panels.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Biomarcadores Tumorais/genética , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Mutação
3.
Clin Lung Cancer ; 21(1): 56-65.e8, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31519454

RESUMO

BACKGROUND: The introduction of liquid biopsy using PCR-based assays into routine practice has had a strong impact on the treatment of EGFR-mutated lung adenocarcinoma and is now commonly used for routine testing of EGFR mutations in certain clinical settings. To assess whether the claimed benefits of PCR-based assays hold true in daily practice at a multicenter clinical institution, we assessed how treatment decisions are affected by PCR-based assays for the analysis of EGFR mutations from plasma samples in a centralized laboratory (LPCE, Nice, France). PATIENTS AND METHODS: A total of 345 samples were analyzed using the US Food and Drug Administration-approved Cobas EGFR Mutation Test v2 and 103 using the Therascreen EGFR Plasma RGQ PCR Kit over 3 years (395 samples from 324 patients). Eleven plasma samples were validated independently using Cobas at 3 institutions, and 130 samples were analyzed using Stilla digital PCR. Clinical data were collected for 175 (54%) of 324 patients. RESULTS: Cobas was superior to the Therascreen assay and demonstrated 100% reproducibility. Digital PCR showed only 48%, 83%, and 58% concordance with Cobas for exon 19 deletions, L858R mutations, and T790M mutations, respectively. Liquid biopsies helped inform and change treatment when resistance occurred and enabled the detection of EGFR mutations in patients when biopsy tissue results were unavailable. CONCLUSION: PCR-based assays are a fast and convenient test, allowing the detection of primary and secondary EGFR mutations from plasma. Cobas proved to be a reliable test, whereas digital PCR produced too many inconclusive results to be currently recommended as a principal testing device.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Técnicas de Laboratório Clínico/normas , Análise Mutacional de DNA/métodos , Neoplasias Pulmonares/diagnóstico , Mutação , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/genética , Receptores ErbB/genética , Feminino , França , Humanos , Biópsia Líquida , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/genética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
Cancers (Basel) ; 10(4)2018 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-29561830

RESUMO

Background: With the integration of various targeted therapies into the clinical management of patients with advanced lung adenocarcinoma, next-generation sequencing (NGS) has become the technology of choice and has led to an increase in simultaneously interrogated genes. However, the broader adoption of NGS for routine clinical practice is still hampered by sophisticated workflows, complex bioinformatics analysis and medical interpretation. Therefore, the performance of the novel QIAGEN GeneReader NGS system was compared to an in-house ISO-15189 certified Ion PGM NGS platform. Methods: Clinical samples from 90 patients (60 Retrospectively and 30 Prospectively) with lung adenocarcinoma were sequenced with both systems. Mutations were analyzed and EGFR, KRAS, BRAF, NRAS, ALK, PIK3CA and ERBB2 genes were compared and sampling time and suitability for clinical testing were assessed. Results: Both sequencing systems showed perfect concordance for the overlapping genes. Correlation of allele frequency was r² = 0.93 for the retrospective patients and r² = 0.81 for the prospective patients. Hands-on time and total run time were shorter using the PGM system, while the GeneReader platform provided good traceability and up-to-date interpretation of the results. Conclusion: We demonstrated the suitability of the GeneReader NGS system in routine practice in a clinical pathology laboratory setting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA