Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 9: 839714, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35449873

RESUMO

Background: Obesity exerts multiple deleterious effects on the heart that may ultimately lead to cardiac failure. This study sought to characterize myocardial microstructure and function in an experimental model of obesity-related cardiac dysfunction. Methods: Male C57BL/6N mice were fed either a high-fat diet (HFD; 60 kcal% fat, n = 12) or standard control diet (9 kcal% fat, n = 10) for 15 weeks. At the end of the study period, cardiac function was assessed by ultra-high frequency echocardiography, and hearts were processed for further analyses. The three-dimensional myocardial microstructure was examined ex vivo at a spatial resolution of 100 × 100 × 100 µm3 by diffusion tensor magnetic resonance imaging (DT-MRI) at 7T. Myocardial deformation, diffusion metrics and fiber tract geometry were analyzed with respect to the different myocardial layers (subendocardium/subepicardium) and segments (base/mid-cavity/apex). Results were correlated with blood sample analyses, histopathology, and gene expression data. Results: HFD feeding induced significantly increased body weight combined with a pronounced accumulation of visceral fat (body weight 42.3 ± 5.7 vs. 31.5 ± 2.2 g, body weight change 73.7 ± 14.8 vs. 31.1 ± 6.6%, both P < 0.001). Obese mice showed signs of diastolic dysfunction, whereas left-ventricular ejection fraction and fractional shortening remained unchanged (E/e' 41.6 ± 16.6 vs. 24.8 ± 6.0, P < 0.01; isovolumic relaxation time 19 ± 4 vs. 14 ± 4 ms, P < 0.05). Additionally, global longitudinal strain was reduced in the HFD group (-15.1 ± 3.0 vs. -20.0 ± 4.6%, P = 0.01), which was mainly driven by an impairment in basal segments. However, histopathology and gene expression analyses revealed no myocardial fibrosis or differences in cardiomyocyte morphology. Mean diffusivity and eigenvalues of the diffusion tensor were lower in the basal subepicardium of obese mice as assessed by DT-MRI (P < 0.05). The three-dimensional fiber tract arrangement of the left ventricle (LV) remained preserved. Conclusion: Fifteen weeks of high-fat diet induced alterations in myocardial diffusion properties in mice, whereas no remodeling of the three-dimensional myofiber arrangement of the LV was observed. Obese mice showed reduced longitudinal strain and lower mean diffusivity predominantly in the left-ventricular base, and further investigation into the significance of this regional pattern is required.

2.
J Cardiovasc Magn Reson ; 15: 49, 2013 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-23758805

RESUMO

Cardiovascular magnetic resonance (CMR) studies in patients with pacemakers or implantable cardioverter/defibrillators (ICD) are increasingly required in daily clinical practice. Therefore, in the last years the manufacturers developed not only MR-conditional pacemakers, but also MR-conditional ICDs. However, the clinical experience regarding the feasibility and limitations of MR studies of the heart in patients with ICDs is still limited. In particular, there are hardly any CMR studies in the same patients performed prior to and post ICD implantation allowing a one-to-one comparison of the obtained CMR images. This is the first presentation of a CMR study in a patient with the world's first and so far only MR-conditional ICD. In our case, a major problem related to the presence of the MR conditional ICD was an image artifact caused by the device's generator which hampered the visualization of the midventricular and apical anterior and antero-lateral segments in all sequences performed. Considering previous studies, right chest implantation of the ICD could probably have helped in this setting and may be preferred in future ICD implantations. Our case report nicely illustrates the real clinical need for specially designed implantable devices that ensure safe and high-quality imaging in patients in whom serial CMR is required.


Assuntos
Artefatos , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética/métodos , Distrofias Musculares/complicações , Adulto , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia Ambulatorial , Segurança de Equipamentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA