Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
BMC Cardiovasc Disord ; 17(1): 121, 2017 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-28490380

RESUMO

BACKGROUND: ICDs efficiently terminate life-threatening arrhythmias, but complications occur during long-term follow-up. Patients' own perspective is largely unknown. The aim of the study was to describe experiences of hypertrophic cardiomyopathy (HCM) patients with implantable defibrillators (ICDs). METHODS: We analyzed 26 Swedish patient interviews using hermeneutics and latent content analysis. RESULTS: Patients (aged 27-76 years) were limited by HCM especially if it deteriorates into heart failure. The ICD implies safety, gratitude, and is accepted as a part of the body even when inappropriate ICD shocks are encountered. Nobody regretted the implant. Both the disease and the ICD affected professional life and leisure time activities, especially at younger ages. Family support was usually strong, but sometimes resulted in overprotection, whereas health care focused on medical issues. Despite limitations, patients adapted, accepted, and managed challenges. CONCLUSION: HCM patients with ICDs reported good spirit and hope even though they had to adapt and accept limitations over time.


Assuntos
Arritmias Cardíacas/prevenção & controle , Cardiomiopatia Hipertrófica/cirurgia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/instrumentação , Qualidade de Vida , Atividades Cotidianas , Adaptação Psicológica , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/psicologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/psicologia , Efeitos Psicossociais da Doença , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/psicologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/psicologia , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Hermenêutica , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde , Satisfação do Paciente , Falha de Prótese , Pesquisa Qualitativa , Suécia , Fatores de Tempo , Resultado do Tratamento
2.
Eur J Echocardiogr ; 10(1): 56-61, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18490292

RESUMO

UNLABELLED: Aim To elucidate the complexity of left ventricular motion throughout the cardiac cycle, we studied regional rotation in detail. METHODS AND RESULTS: Regional rotation in six subdivisions of the circumference at three levels was studied by using speckle-tracking echocardiography in 40 healthy subjects. At the basal level the inferoseptal segments rotated significantly more clockwise during systole than the opposing anterolateral segments. At the papillary level the inferoseptal segments differed significantly from the anterolateral segments, where the inferoseptal segments rotated clockwise and the anterolateral segments rotated counter-clockwise. The apical level showed significant difference in regional rotation only at aortic valve opening. In early systole, untwist before the main systolic twist was seen at the basal and apical levels; however, the duration of the basal untwist was much longer than that of the apical. The diastolic phases of rotation at the basal and apical levels matched the different filling phases. CONCLUSION: Large regional differences in rotation are present at the basal and papillary levels in healthy subjects. The diastolic untwist matches the phases of both the E-wave and A-wave and seems to be related with intraventricular pressure differences, indicating that untwist plays an important role in the filling of the ventricle.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Adulto , Idoso , Análise de Variância , Estudos de Coortes , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Variações Dependentes do Observador , Probabilidade , Valores de Referência , Rotação , Sensibilidade e Especificidade , Sístole/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA