Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Intern Emerg Med ; 16(4): 957-966, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33165755

RESUMO

Recently the coronavirus disease (COVID-19) outbreak has been declared a pandemic. Despite its aggressive extension and significant morbidity and mortality, risk factors are poorly characterized outside China. We designed a registry, HOPE COVID-19 (NCT04334291), assessing data of 1021 patients discharged (dead or alive) after COVID-19, from 23 hospitals in 4 countries, between 8 February and 1 April. The primary end-point was all-cause mortality aiming to produce a mortality risk score calculator. The median age was 68 years (IQR 52-79), and 59.5% were male. Most frequent comorbidities were hypertension (46.8%) and dyslipidemia (35.8%). A relevant heart or lung disease were depicted in 20%. And renal, neurological, or oncological disease, respectively, were detected in nearly 10%. Most common symptoms were fever, cough, and dyspnea at admission. 311 patients died and 710 were discharged alive. In the death-multivariate analysis, raised as most relevant: age, hypertension, obesity, renal insufficiency, any immunosuppressive disease, 02 saturation < 92% and an elevated C reactive protein (AUC = 0.87; Hosmer-Lemeshow test, p > 0.999; bootstrap-optimist: 0.0018). We provide a simple clinical score to estimate probability of death, dividing patients in four grades (I-IV) of increasing probability. Hydroxychloroquine (79.2%) and antivirals (67.6%) were the specific drugs most commonly used. After a propensity score adjustment, the results suggested a slight improvement in mortality rates (adjusted-ORhydroxychloroquine 0.88; 95% CI 0.81-0.91, p = 0.005; adjusted-ORantiviral 0.94; 95% CI 0.87-1.01; p = 0.115). COVID-19 produces important mortality, mostly in patients with comorbidities with respiratory symptoms. Hydroxychloroquine could be associated with survival benefit, but this data need to be confirmed with further trials. Trial Registration: NCT04334291/EUPAS34399.


Assuntos
COVID-19/mortalidade , Idoso , COVID-19/complicações , COVID-19/terapia , Feminino , Hospitalização , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Sistema de Registros , Medição de Risco , Fatores de Risco , Espanha , Taxa de Sobrevida
2.
J Am Heart Assoc ; 9(4): e014458, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-32063120

RESUMO

Background Sex-specific differences may influence prognosis after deferred revascularization following fractional flow reserve (FFR) measurement. This study sought to investigate the sex differences in long-term prognosis of patients with deferred revascularization following FFR assessment. Methods and Results A total of 879 patients (879 vessels) with deferred revascularization with FFR >0.75 who underwent FFR and coronary flow reserve measurements were enrolled from 3 countries (Korea, Japan, and Spain). Long-term outcomes were assessed in 649 men and 230 women by the patient-oriented composite outcome (POCO, a composite of any death, any myocardial infarction, and any revascularization). We applied inverse-probability weighting based on propensity scores to account for differences at baseline between women and men (age, hyperlipidemia, diabetes mellitus, diameter stenosis, lesion length, multivessel disease, FFR, coronary flow reserve. The median follow-up duration was 1855 days (745-1855 days). Median FFR values were 0.88 (0.83-0.93) in men and 0.89 (0.85-0.94) in women, respectively. The occurrences of POCO were significantly high in men compared with that in women (10.5% versus 4.2%, P=0.007). Kaplan-Meier analysis revealed that women had a significantly lower risk of POCO (χ2=7.2, P=0.007). Multivariate COX proportional hazards regression analysis revealed that age, male, diabetes mellitus, diameter stenosis, lesion length, and coronary flow reserve were independent predictors of POCO. After applying IPW, the hazard ratio of males for POCO was 2.07 (95% CI, 1.07-4.04, P=0.032). Conclusions This large multinational study reveals that long-term outcome differs between women and men in favor of women after FFR-guided revascularization deferral. Clinical Trial Registration URL: http://www.ClinicalTrials.gov. Unique identifier: NCT02186093.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Revascularização Miocárdica , Sistema de Registros , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Japão , Masculino , República da Coreia , Fatores Sexuais , Espanha , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
3.
EuroIntervention ; 15(18): e1594-e1601, 2020 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-31543501

RESUMO

AIMS: Functional assessment of non-culprit lesions (NCL) in patients presenting with ST-elevation myocardial infarction (STEMI) and multivessel disease constitutes an unmet need. This study aimed to evaluate the diagnostic accuracy of quantitative flow ratio (QFR) in the functional assessment of NCL during the acute phase of STEMI. METHODS AND RESULTS: This was a retrospective, observational, multicentre study including patients with STEMI and staged fractional flow reserve (FFR) assessment of NCL. QFR in NCL was calculated from the coronary angiogram acquired during primary PCI in a blinded fashion with respect to FFR. The diagnostic value of QFR in the STEMI population was compared with a propensity score-matched population of stable angina patients. Eighty-two patients (91 NCL) were included. Target lesions were of both angiographic and functional (mean FFR 0.82±0.09) intermediate severity. The diagnostic performance of QFR was high (AUC 0.91 [95% CI: 0.85-0.97]) and similar to that observed in the matched control population (AUC 0.91 vs 0.94, p=0.5). The diagnostic accuracy of QFR was very high (>95%) in those vessels (61.5%) with QFR values out of a ROC-defined "grey zone" (0.75-0.85). A hybrid FFR/QFR approach (FFR only when QFR is in the grey zone) would adequately classify 96.7% of NCL, avoiding 58.5% of repeat diagnostic procedures. CONCLUSIONS: QFR has a good diagnostic accuracy in assessing the functional relevance of NCL during primary PCI, similar to the accuracy observed in stable patients.


Assuntos
Estenose Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Índice de Gravidade de Doença
4.
JACC Cardiovasc Interv ; 11(8): 741-753, 2018 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-29673505

RESUMO

OBJECTIVES: The authors sought to evaluate the influence of coronary microcirculatory dysfunction (CMD) on the diagnostic performance of the quantitative flow ratio (QFR). BACKGROUND: Functional angiographic assessment of coronary stenoses based on fluid dynamics, such as QFR, constitutes an attractive alternative to fractional flow reserve (FFR). However, it is unknown whether CMD affects the reliability of angiography-based functional indices. METHODS: FFR and the index of microcirculatory resistance (IMR) were measured in 300 vessels (248 patients) as part of a multicenter international registry. QFR was calculated at a blinded core laboratory. Vessels were classified into 2 groups according to microcirculatory status: low IMR (<23 U), and high IMR (≥23 U, CMD). The impact of CMD on the diagnostic performance of QFR, as well as on incremental value of QFR over quantitative angiography, was assessed using FFR as reference. RESULTS: Percent diameter stenosis (%DS) and FFR were similar in low- and high-IMR groups (%DS 51 ± 12% vs. 53 ± 11%; p = 0.16; FFR 0.80 ± 0.11 vs. 0.81 ± 0.11; p = 0.23, respectively). In the overall cohort, classification agreement (CA) between QFR and FFR and diagnostic efficiency of QFR (area under the receiver-operating characteristics curve [AUC]) were high (CA: 88%; AUC: 0.93 [95% confidence interval (CI): 0.90 to 0.96]). However, when assessed according to microcirculatory status, a significantly lower CA and AUC of QFR were found in the high-IMR group as compared with the low-IMR group (CA: 76% vs. 92%; p < 0.001; AUC: 0.88 [95% CI: 0.79 to 0.94] vs. 0.96 [95% CI: 0.92 to 0.98]; p < 0.05). Compared with angiographic assessment, QFR increased by 0.20 (p < 0.001) and by 0.16 (p < 0.001) the AUC of %DS in low- and high-IMR groups, respectively. Independent predictors of misclassification between QFR and FFR were high IMR and acute coronary syndrome. CONCLUSIONS: CMD decreases the diagnostic performance of QFR. However, even in the presence of CMD, QFR remains superior to angiography alone in ascertaining functional stenosis severity.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Microcirculação , Idoso , Cateterismo Cardíaco , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Seul , Índice de Gravidade de Doença
5.
Cardiovasc Revasc Med ; 19(5 Pt B): 589-596, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29276176

RESUMO

BACKGROUND: Coronary aneurysms (1.5 times dilation the reference-vessel) are uncommon and have been diagnosed with increasing frequency with coronary angiography. The incidence varies from 1.5% to 5%. Reported complications are multiple: thrombosis, distal embolization, rupture and vasospasm, causing ischemia, heart failure or arrhythmias. However, the natural history and prognosis remains obscure. We aimed to describe the characteristics of acute patients with coronary aneurysms. METHODS: Prospective coronariography registry of patients with the diagnosis of coronary aneurysm between 2002 and 2013. Among 51,555 consecutive coronary angiograms, 414 patients with aneurysms were reported, of which 256 were considered acute (82% NSTE-ACS). RESULTS: Predominantly male (80%, mean age 65.5years), cardiovascular risk factors were common (hypertension 65%, dyslipidemia 65%, obesity 25%, diabetes mellitus 28.5%, and smokers 67%). With frequent coronary stenoses (94%), mostly with one aneurysm (80%), it was observed more frequently in the anterior descending artery. After a median follow-up of 52months, 53 died (14 cardiac causes) and 42% presented a cardiovascular event. Complications from the aneurysm were found in 4. The duration of dual antiplatelet therapy, LVEF, age and peripheral vascular disease highlighted in the multivariate analysis of death. CONCLUSION: The presence of coronary aneurysms in patients undergoing coronary angiography with an acute event is low. Patients who present them also have a large burden of atherosclerotic risk factors. In the long-term, the probability of cardiovascular complications is high, but only a small proportion are due to the aneurysm itself. A more intense and prolonged antithrombotic treatment may result in lower mortality rates.


Assuntos
Aneurisma Coronário/epidemiologia , Doença Aguda , Idoso , Comorbidade , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/mortalidade , Aneurisma Coronário/terapia , Angiografia Coronária , Bases de Dados Factuais , Progressão da Doença , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Fatores de Tempo
6.
EuroIntervention ; 13(8): 944-952, 2017 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-28485281

RESUMO

AIMS: The index of microcirculatory resistance (IMR) is increasingly used to quantify microcirculatory function. However, in normal coronary arteries, resistance increases with the branching structure of the coronary tree, which suggests that IMR could be influenced by the amount of downstream myocardial mass (MM). We aimed to evaluate the influence of the amount of MM subtended to an intermediate stenosis on the IMR. METHODS AND RESULTS: IMR, fractional flow reserve and coronary flow reserve (CFR) were measured in 123 coronary arteries (102 patients) with intermediate stenosis. Jeopardised MM was estimated with the Myocardial Jeopardy Index (MJI). MM was inversely associated with IMR (R.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Microcirculação/fisiologia , Resistência Vascular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Isquemia Miocárdica/fisiopatologia
7.
BMJ Open ; 5(12): e009148, 2015 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-26656019

RESUMO

OBJECTIVES: To evaluate the cost-effectiveness of the ST-segment elevation myocardial infarction (STEMI) network of Catalonia (Codi Infart). DESIGN: Cost-utility analysis. SETTING: The analysis was from the Catalonian Autonomous Community in Spain, with a population of about 7.5 million people. PARTICIPANTS: Patients with STEMI treated within the autonomous community of Catalonia (Spain) included in the IAM CAT II-IV and Codi Infart registries. OUTCOME MEASURES: Costs included hospitalisation, procedures and additional personnel and were obtained according to the reperfusion strategy. Clinical outcomes were defined as 30-day avoided mortality and quality-adjusted life-years (QALYs), before (N=356) and after network implementation (N=2140). RESULTS: A substitution effect and a technology effect were observed; aggregate costs increased by 2.6%. The substitution effect resulted from increased use of primary coronary angioplasty, a relatively expensive procedure and a decrease in fibrinolysis. Primary coronary angioplasty increased from 31% to 89% with the network, and fibrinolysis decreased from 37% to 3%. Rescue coronary angioplasty declined from 11% to 4%, and no reperfusion from 21% to 4%. The technological effect was related to improvements in the percutaneous coronary intervention procedure that increased efficiency, reducing the average length of the hospital stay. Mean costs per patient decreased from €8306 to €7874 for patients with primary coronary angioplasty. Clinical outcomes in patients treated with primary coronary angioplasty did not change significantly, although 30-day mortality decreased from 7.5% to 5.6%. The incremental cost-effectiveness ratio resulted in an extra cost of €4355 per life saved (30-day mortality) and €495 per QALY. Below a cost threshold of €30,000, results were sensitive to variations in costs and outcomes. CONCLUSIONS: The Catalan STEMI network (Codi Infart) is cost-efficient. Further studies are needed in geopolitical different scenarios.


Assuntos
Tempo de Internação/economia , Infarto do Miocárdio/economia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/economia , Idoso , Angioplastia Coronária com Balão , Análise Custo-Benefício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Sistema de Registros , Espanha
8.
JACC Cardiovasc Interv ; 8(13): 1681-91, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26585618

RESUMO

OBJECTIVES: This study sought to understand the physiological basis of baseline distal-to-aortic pressure ratio (Pd/Pa) and fractional flow reserve (FFR) agreement and discordance, using coronary flow reserve (CFR), stenosis resistance, and microcirculatory resistance measurements, and form there, to investigate the potential value of combining Pd/Pa with FFR in the diagnostic rationale. BACKGROUND: Pd/Pa is always available before FFR assessment, and emerging data supports the notion that baseline indices can determine the ischemic potential of coronary stenosis in selected subsets. METHODS: A total of 467 stenosed vessels from 363 patients were investigated with pressure and flow sensors during baseline and hyperemia: 168 vessels (135 patients) with thermodilution-derived flow, and 299 vessels (228 patients) with Doppler-derived flow. RESULTS: Pd/Pa correlated more strongly with CFR than FFR (ρ difference = 0.129; p for ρ comparison <0.001). Although Pd/Pa and FFR were closely correlated (ρ = 0.798; 95% confidence interval: 0.767 to 0.828), categorical discordance was observed in 19.3% of total vessels. Such discordance was associated with the patients' clinical profile and was characterized by contrastive changes in stenosis resistance, microcirculatory resistance, and the underlying CFR. Notably, all stenosis with Pd/Pa ≤0.83 (n = 74, 15.8%) progressed to FFR ≤0.80, and although no Pd/Pa cutoff was able to exclude the development of FFR ≤0.80 in the high end of values, only 15 (10.1%) vessels with Pd/Pa ≥0.96 (n = 149, 31.9%) developed FFR ≤0.80, from which none had definite ischemia, as defined by CFR ≤1.74. CONCLUSIONS: Combining baseline Pd/Pa with FFR seems to provide a more comprehensive physiological examination of stenosed coronary arteries and a closer pressure-based appraisal of the flow reserve of the downstream myocardial bed.


Assuntos
Aorta/fisiopatologia , Pressão Arterial , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Aorta/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Microcirculação , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Termodiluição , Transdutores de Pressão , Resistência Vascular
9.
Circulation ; 131(24): 2114-9, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25888682

RESUMO

BACKGROUND: Aortic dissection type A is a disease with high mortality. Iatrogenic aortic dissection after interventional procedures is infrequent, and prognostic data are scarce. Our objective was to analyze its incidence, patient profile, and long-term prognosis. METHODS AND RESULTS: Between 2000 and 2014, we retrospectively analyzed 74 patients with dissection of the ascending aorta. Clinical and procedural data were reviewed, and later, we performed a prospective clinical follow-up by telephone or in the office. The incidence of aortic dissection was 0.06%. Our patients, predominantly male (67.6%), had a mean age of 66.9±10.8 years. With multiple cardiovascular risk factors, the main reason for cardiac catheterization was an acute coronary syndrome (n=54). The complication was detected acutely in all, trying to engage the right coronary artery in 47 and the left main artery in 30 and after other maneuvers in 2, mostly complex therapeutic procedures (78.4%). A coronary artery was involved in 45 patients (60.8%). Thirty-five patients underwent an angioplasty and stent implantation; 3 had cardiac surgery; and 36 were managed conservatively. Two patients died of cardiogenic shock after the dissection. After a median follow-up of 51.2 months (range, 16.4-104.8 months), none of the remaining patients developed complications as a result of the dissection, progression, ischemia, pain, or dissection recurrence. CONCLUSIONS: Iatrogenic catheter dissection of the aorta is a rare complication that carries an excellent short- and long-term prognosis with the adoption of a conservative approach. When a coronary artery is involved as an entry point, it usually can be safely sealed with a stent with good long-term outcomes.


Assuntos
Aorta/lesões , Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Cateterismo Cardíaco/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Idoso , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/cirurgia , Dissecção Aórtica/terapia , Anticoagulantes/efeitos adversos , Aneurisma Aórtico/epidemiologia , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/terapia , Bases de Dados Factuais , Europa (Continente)/epidemiologia , Feminino , Fibrinolíticos/efeitos adversos , Seguimentos , Humanos , Doença Iatrogênica , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Stents , Resultado do Tratamento
10.
J Am Soc Echocardiogr ; 27(8): 838-45, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24909790

RESUMO

BACKGROUND: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has important technical limitations for mitral valve orifice area (MVA) assessment in mitral stenosis (MS), mainly the geometric assumptions of PISA shape and the requirement of an angle correction factor. Single-beat real-time three-dimensional (3D) color Doppler imaging allows the direct measurement of PISA without geometric assumptions or the requirement of an angle correction factor. The aim of this study was to validate this method in patients with rheumatic MS. METHODS: Sixty-three consecutive patients with rheumatic MS were included. MVA was assessed using the transthoracic 2D and 3D PISA methods. Planimetry of MVA (2D and 3D) and the pressure half-time method were used as reference methods. RESULTS: The 3D PISA method had better correlations with the reference methods (with 2D planimetry, r = 0.85, P < .001; with 3D planimetry, r = 0.89, P < .001; and with pressure half-time, r = 0.85, P < .001) than the conventional 2D PISA method (with 2D planimetry, r = 0.63, P < .001; with 3D planimetry, r = 0.66, P < .001; and with pressure half-time, r = 0.68, P < .001). In addition, a consistent significant underestimation of MVA using the conventional 2D PISA method was observed. A high percentage (30%) of patients with nonsevere MS by 3D planimetry were misclassified by the 2D PISA method as having severe MS (effective regurgitant orifice area < 1 cm(2)). In contrast, the 3D PISA method had 94% agreement with 3D planimetry. Good intra- and interobserver agreement for 3D PISA measurements were observed, with intraclass correlation coefficients of 0.95 and 0.90, respectively. CONCLUSIONS: MVA assessment using PISA by single-beat real-time 3D color Doppler echocardiography is feasible in the clinical setting and more accurate than the conventional 2D PISA method.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Cardiopatia Reumática/diagnóstico por imagem , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Cardiopatia Reumática/complicações , Cardiopatia Reumática/fisiopatologia , Índice de Gravidade de Doença
12.
Circ Cardiovasc Interv ; 7(1): 35-42, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24399244

RESUMO

BACKGROUND: Intravenous adenosine infusion produces coronary and systemic vasodilatation, generally leading to systemic hypotension. However, adenosine-induced hypotension during stable hyperemia is heterogeneous, and its relevance to coronary stenoses assessment with fractional flow reserve (FFR) remains largely unknown. METHODS AND RESULTS: FFR, coronary flow reserve, and index of microcirculatory resistance were measured in 93 stenosed arteries (79 patients). Clinical and intracoronary measurements were analyzed among tertiles of the percentage degree of adenosine-induced hypotension, defined as follows: %ΔP(a)=-[100-(hyperemic aortic pressure×100/baseline aortic pressure)]. Overall, %ΔP(a) was -13.6±12.0%. Body mass index was associated with %ΔP(a) (r=0.258; P=0.025) and obesity, an independent predictor of profound adenosine-induced hypotension (tertile 3 of %ΔP(a); odds ratio, 3.95 [95% confidence interval, 1.48-10.54]; P=0.006). %ΔP(a) was associated with index of microcirculatory resistance (ρ=0.311; P=0.002), coronary flow reserve (r=-0.246; P=0.017), and marginally with FFR (r=0.203; P=0.051). However, index of microcirculatory resistance (ß=0.003; P<0.001) and not %ΔP(a) (ß=-0.001; P=0.564) was a predictor of FFR. Compared with tertiles 1 and 2 of %ΔP(a) (n=62 [66.6%]), stenoses assessed during profound adenosine-induced hypotension (n=31 [33.3%]) had lower index of microcirculatory resistance (12.4 [8.6-22.7] versus 20 [15.8-35.5]; P=0.001) and FFR values (0.77±0.13 versus 0.83±0.12; P=0.021), as well as a nonsignificant increase in coronary flow reserve (2.5±1.1 versus 2.2±0.87; P=0.170). CONCLUSIONS: The modification of systemic blood pressure during intravenous adenosine infusion is related to hyperemic microcirculatory resistance in the heart. Profound adenosine-induced hypotension is associated with obesity, lower coronary microcirculatory resistance, and lower FFR values.


Assuntos
Adenosina/administração & dosagem , Estenose Coronária/diagnóstico , Hipotensão/diagnóstico , Vasodilatadores/administração & dosagem , Adenosina/efeitos adversos , Idoso , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Índice de Massa Corporal , Estenose Coronária/complicações , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Humanos , Hipotensão/etiologia , Infusões Intravenosas , Masculino , Microcirculação/efeitos dos fármacos , Pessoa de Meia-Idade , Fatores de Risco , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/efeitos adversos
14.
Int J Cardiol ; 166(3): 640-5, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22192301

RESUMO

BACKGROUND: 3D echocardiography provides a complete evaluation of the aortic valve and adjacent structures and it improves the assessment of this cardiac region. Three-dimensional color-Doppler echocardiography (3DCDE) evaluation might improve the measurements of the functional regurgitant orifice in patients with Chronic Aortic Regurgitation (CAR). OBJECTIVES: Our aim was to compare the accuracy of current echo-Doppler methods and 3DCDE for the assessment of CAR severity. The reference method used in this work was the CAR severity determined by means of cardiac magnetic resonance (CMR) METHODS: Thirty-two consecutive patients with an established diagnosis of CAR recruited in our institution comprised our study group. CAR severity was determined by conventional Echo-Doppler methods and by 3DCDE and their results were compared with those obtained by means of CMR. RESULTS: Mean age was 63.0 ± 13.5 years. Twenty-two patients (68.8%) were men. Compared with the traditional echo-Doppler methods, 3DCDE evaluation had the best linear association with CMR results (3D vena contracta cross sectional area method: r = 0.88; r square = 0.77; p < 0.001. 3D vena contracta cross sectional area/left ventricular outflow tract cross sectional area method: r = 0.87; r square = 0.75; p < 0.001). The ROC analysis showed an excellent area under curve for detection of severe CAR (3D vena contracta cross sectional area method = 0.97; 3D vena contracta cross sectional area/left ventricular outflow tract cross sectional area method = 0.98). Inter- and intra-observer variability for the 3DCDE evaluation was good (ICC = 0.89 and ICC = 0.91 for inter and intra observer variability respectively). CONCLUSIONS: 3DCDE is an accurate and highly reproducible diagnostic tool for estimating CAR severity. Compared with the traditional echo-Doppler methods, 3DCDE has the best agreement with the CMR determined CAR severity. Thus, 3DCDE is a diagnostic method that may improve the therapeutic management of patients with CAR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Índice de Gravidade de Doença , Idoso , Insuficiência da Valva Aórtica/epidemiologia , Ecocardiografia Doppler em Cores/normas , Ecocardiografia Tridimensional/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
EuroIntervention ; 8 Suppl P: P90-3, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22917800

RESUMO

Early reperfusion of the occluded artery is the mainstay of the treatment of ST-segment elevation myocardial infarction (STEMI), and the best way to coordinate the resources to deliver optimal care as soon as possible is through STEMI networks. Coordination of the healthcare system is the responsibility of each of the 17 different autonomous communities in Spain. Since 2002, when the first STEMI network in Spain was established, six other communities have developed regional networks, covering 39% of the population in Spain. In the autonomous communities, after implementing an intervention model, an improvement in the reperfusion times with an increase in the number of primary percutaneous coronary interventions has been observed. This optimisation of the system has resulted in a decrease in the mortality rate among STEMI patients treated in Spanish communities with a STEMI network. Despite the encouraging advances, the challenge remains of assuring equity of treatment for all of our patients regardless of their region of residence.


Assuntos
Prestação Integrada de Cuidados de Saúde/organização & administração , Acessibilidade aos Serviços de Saúde/organização & administração , Planejamento Hospitalar/organização & administração , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Prestação Integrada de Cuidados de Saúde/normas , Acessibilidade aos Serviços de Saúde/normas , Planejamento Hospitalar/normas , Humanos , Modelos Organizacionais , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Objetivos Organizacionais , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Espanha , Fatores de Tempo , Tempo para o Tratamento/organização & administração , Resultado do Tratamento
16.
Eur Heart J Cardiovasc Imaging ; 13(11): 931-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22511810

RESUMO

AIMS: Paravalvular aortic regurgitation (AR) is common after transcatheter aortic valve implantation (TAVI). This study aimed to assess the prosthesis/aortic annulus discongruence by three-dimensional (3D) transoesophageal (TOE) planimetry of aortic annulus and its impact on the occurrence of significant AR after TAVI. METHODS AND RESULTS: We included 33 patients who underwent TAVI with a balloon expandable device for severe aortic stenosis. To appraise the prosthesis/annulus discongruence, we defined a 'mismatch index' expressed as: annulus area - prosthesis area. The aortic annulus area was planimetered with 3D TOE, and approximated by circular area formula (π r(2)) using annulus diameter obtained by two-dimensional (2D) TOE. After TAVI, 13 patients (39.3%) developed significant AR (≥2/4). The occurrence of significant AR was associated to the 3D planimetered annulus area (P = 0.04), and the 'mismatch index' obtained through 3D planimetered annulus area (P = 0.03), but not to 'mismatch index' derived of 2D annulus diameter. In multivariate analysis, 'mismatch index' for 3D planimetered annulus area was the only independent predictor of significant AR (odds ratio: 10.614; 95% CI: 1.044-17.21; P = 0.04). The area under the receiver operating characteristic curve for the 'mismatch index' by the 3D planimetered annulus area was 0.76 (95% CI: 0.54-0.92), whereas for 'mismatch index' obtained by the 2D circular area was 0.36 (95% CI: 0.17-0.55). Using the 3D planimetered annulus area as the reference parameter to decide the prosthetic size, the choice would have been different in 21 patients (63%). CONCLUSION: Three-dimensional TOE planimetry of aortic annulus improves the assessment of prosthesis/annulus discongruence and predicts the appearance of significant AR after TAVI.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/cirurgia , Intervalos de Confiança , Indicadores Básicos de Saúde , Humanos , Razão de Chances , Curva ROC , Estudos Retrospectivos , Índice de Gravidade de Doença , Estatística como Assunto , Estatísticas não Paramétricas
17.
J Am Coll Cardiol ; 59(12): 1080-9, 2012 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-22421301

RESUMO

OBJECTIVES: The study sought to assess the diagnostic efficiency of optical coherence tomography (OCT) in identifying hemodynamically severe coronary stenoses as determined by fractional flow reserve (FFR). Concomitant OCT and intravascular ultrasound (IVUS) area measurements were performed in a subgroup of patients to compare the diagnostic efficiency of both techniques. BACKGROUND: The value of OCT to determine stenosis severity remains unsettled. METHODS: Sixty-one stenoses with intermediate angiographic severity were studied in 56 patients. Stenoses were labeled as severe if FFR ≤0.80. OCT interrogation was performed in all cases, with concomitant IVUS imaging in 47 cases. RESULTS: Angiographic stenosis severity was 50.9 ± 8% diameter stenosis with 1.28 ± 0.3 mm minimal lumen diameter. FFR was ≤0.80 in 28 (45.9%) stenoses. An overall moderate diagnostic efficiency of OCT was found (area under the curve [AUC]: 0.74; 95% confidence interval [CI]: 0.61 to 0.84), with sensitivity/specificity of 82%/63% associated with an optimal cutoff value of 1.95 mm(2). Comparison of the results in patients with simultaneous IVUS and OCT imaging revealed no significant differences in the diagnostic efficiency of OCT (AUC: 0.70; 95% CI: 0.55 to 0.83) and IVUS (AUC. 0.63; 95% CI: 0.47 to 0.77; p = 0.19). Sensitivity/specificity for IVUS was 67%/65% for an optimal cutoff value of 2.36 mm(2). In the subgroup of small vessels (reference diameter <3 mm) OCT showed a significantly better diagnostic efficiency (AUC: 0.77; 95% CI: 0.60 to 0.89) than IVUS (AUC: 0.63; 95% CI: 0.46 to 0.78) to identify functionally significant stenoses (p = 0.04). CONCLUSIONS: OCT has a moderate diagnostic efficiency in identifying hemodynamically severe coronary stenoses. Although OCT seems slightly superior to IVUS for this purpose (particularly in vessels <3 mm), its low specificity precludes its use as a substitute of FFR for functional stenosis assessment.


Assuntos
Estenose Coronária/patologia , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Fatores de Risco , Índice de Gravidade de Doença
18.
J Am Soc Echocardiogr ; 25(1): 47-55, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21962448

RESUMO

BACKGROUND: Paravalvular aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is common, but the evaluation of its severity by two-dimensional (2D) transthoracic echocardiography (TTE) presents several constrains. The aim of this study was to assess the usefulness of a new methodology, using three-dimensional (3D) TTE, for better assessment of paravalvular AR after TAVI. METHODS: Two-dimensional and 3D TTE was performed in 72 patients, 5 months after TAVI, using the X5-1 PureWave microbeamforming xMATRIX probe. The position and severity of the paravalvular AR jets were described using 2D and 3D TTE, and a model was designed for paravalvular AR systematic location description. Vena contracta width was measured using 2D transthoracic echocardiographic views, and the planimetry of the vena contracta was assessed after the perfect alignment plane was obtained using the multiplanar 3D transthoracic echocardiographic reconstruction tool. AR volume was calculated as the difference between 3D TTE-derived total left ventricular stroke volume and right ventricular stroke volume estimated using 2D TTE. Diagnostic efficiency for moderate AR was assessed using receiver operating characteristic curve analysis. RESULTS: Forty-three patients (57.4%) presented with AR; 10 (13.3%) had central AR, and 33 (44.0%) had paravalvular AR jets. Vena contracta widths were similar between patients with moderate and mild AR (2.1 ± 0.53 vs 1.9 ± 0.16 mm, P = .16), but vena contracta planimetry was larger in patients with moderate AR than in those with mild AR (0.30 ± 0.12 vs 0.09 ± 0.07 cm(2), P = .001). Vena contracta planimetry on 3D TTE was better correlated with AR volume than vena contracta width on 2D TTE (Kendall's τ = 0.82 [P < .001] vs 0.66 [P < .001]). The areas under the receiver operating characteristic curves were 0.96 for vena contracta planimetry and 0.35 for vena contracta width. CONCLUSIONS: This study proposes an alternative methodology for paravalvular AR assessment after TAVI. Using vena contracta planimetry on 3D TTE, an accurate methodology for paravalvular AR jet evaluation and moderate AR classification is described.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
19.
Rev Esp Cardiol ; 64(7): 557-63, 2011 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-21641709

RESUMO

INTRODUCTION AND OBJECTIVES: One of the aims of secondary prevention is to achieve plaque stabilization. This study sought to investigate the clinical consequences and predictive factors of the change in the type of plaque (CTP) as assessed by serial intracoronary ultrasound in type II diabetic patients with known coronary artery disease. METHODS: 237 segments (45 patients) from the DIABETES I, II, and III trials were included. Intracoronary ultrasound from motorized pullbacks (0.5mm/s) after index procedure and at 9-month angiographic follow-up was performed in the same coronary segment. Nontreated mild lesions (angiographic stenosis <25%) with ≥0.5mm plaque thickening and ≥5mm of length assessed by intracoronary ultrasound were included. As different types of plaques may be encountered throughout a given coronary lesion, each study lesion was divided into 3 segments for serial quantitative and qualitative analyses. Statistical adjustment by multiple lesion segments per patient (generalized estimating equations method) was performed. A CTP was defined as any qualitative change in plaque type at follow-up. At 1-year follow-up, major adverse cardiac events - death, myocardial infarction and target vessel revascularization) - were recorded. RESULTS: A CTP was observed in 48 lesions (20.2%) and occurred more frequently (52.1%) in mixed plaques. Independent predictors of CTP were glycated hemoglobin levels (odds ratio [OR] 1.2; 95% confidence interval [CI] 1.01-1.5; P=.04); glycoprotein IIb-IIIa inhibitors (OR 0.3; 95% CI 0.1-0.7; P=.004) and statin administration (OR 0.3; 95% CI 0.1-0.8; P=.02). At 1-year follow-up CTP was associated with an increase in major adverse cardiac events rate (CTP 20.8% vs non-CTP 13.8%, P=.008; hazard ratio=1.9, 95% CI 1.3-1.9, P=.01). CONCLUSIONS: Qualitative changes in mild stenosis documented by intracoronary ultrasound in type II diabetics are associated with suboptimal secondary prevention and may have clinical consequences. Full English text available from: www.revespcardiol.org.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Estenose Coronária/diagnóstico por imagem , Diabetes Mellitus Tipo 2/complicações , Feminino , Seguimentos , Hemoglobinas Glicadas/análise , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Placa Aterosclerótica/complicações , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Valor Preditivo dos Testes , Prevenção Secundária , Stents , Ultrassonografia
20.
JACC Cardiovasc Interv ; 4(4): 432-41, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21511223

RESUMO

OBJECTIVES: This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. BACKGROUND: The SXscore can identify patients treated with PCI who are at highest risk of adverse events. METHODS: The SXscore was calculated prospectively in 2,033 of the 2,292 patients enrolled in the RESOLUTE All Comers study (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention). Clinical outcomes in terms of a patient-oriented composite endpoint (POCE) of all-cause death, myocardial infarction (MI), and repeat revascularization; the individual components of POCE; target lesion failure (TLF) (a composite of cardiac death, target-vessel MI, and clinically driven target lesion revascularization); and stent thrombosis were subsequently stratified according to SXscore tertiles: SXscore(LOW) ≤ 9 (n = 698), 9 17 (n = 659). RESULTS: At 12-month follow-up, rates of POCE, MI, repeat revascularization, TLF, and the composite of death/MI were all significantly higher in patients in the highest SXscore tercile. Rates of stent thrombosis were all highest in the SXscore(HIGH) tertile (p > 0.05). After multivariate adjustment, the SXscore was identified as an independent predictor of POCE, MI, repeat revascularization, and TLF (p < 0.05 for all). At 12-month follow-up, the SXscore, ACEF score, and Clinical SXscore had C-statistics of 0.57, 0.78, and 0.67, respectively, for mortality and of 0.62, 0.56, 0.63, respectively, for POCE. No significant between-stent differences were observed for TLF or POCE in any of the SXscore tertiles. CONCLUSIONS: The SYNTAX score is able to stratify risk amongst an all-comers population treated with PCI with second-generation drug-eluting stents (DES); however, improvements can be made with the inclusion of clinical variables. (RESOLUTE III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084).


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Indicadores Básicos de Saúde , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Europa (Continente) , Everolimo , Feminino , Humanos , Israel , Estimativa de Kaplan-Meier , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA